IBIC2024 - 13th International Beam Instrumentation Conference

Asia/Shanghai
Wanda Realm Beijing

Wanda Realm Beijing

Beijing, China
Jianshe Cao (Institute of High Energy Physics), Junhui Yue (Institute of High Energy Physics)
    • 13:30 21:00
      Registration 7h 30m
    • 17:30 21:00
      Welcome Reception 3h 30m
    • 09:00 09:10
      TUA: Overview and Commissioning: Welcome & Opening Remarks China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Junhui Yue (Institute of High Energy Physics)
      • 09:00
        Welcome & Opening Remarks 10m
        Speaker: Jianshe Cao (Institute of High Energy Physics)
    • 09:10 09:50
      TUA: Overview and Commissioning: TUAI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Junhui Yue (Institute of High Energy Physics)
      • 09:10
        Overview of Chinese Accelerator 40m

        There are different types accelerators have been operating, constructing and planning.This paper provides a review and the present status of the accelerators in China Which includes collider, FEL, synchrotron light sources, spallation neutron sources, heavy ion accelerator and so on.

        Speaker: Yuhui Li (Chinese Academy of Sciences)
    • 09:50 10:10
      TUA: Overview and Commissioning: TUAC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Junhui Yue (Institute of High Energy Physics)
      • 09:50
        Overview of the FCC-ee beam instrumentation R&D 20m

        The talk shall present an overview of the FCC beam instrumentation needs, the corresponding main challenges. This will review the different R&D activities being currently pursued, including Beam position and loss monitoring, Transverse and longitudinal monitoring systems as well as polarimetry and luminosity monitoring.

        Speaker: Stefano Mazzoni (European Organization for Nuclear Research)
    • 10:10 10:20
      Conference Photo 10m
    • 10:20 10:50
      Morning Coffee Break 30m
    • 10:50 11:50
      TUB: Overview and Commissioning/Transverse Profile and Emittance Monitors: TUBI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Changbum Kim (Pohang Accelerator Laboratory)
      • 10:50
        Commissioning of the beam diagnostic system for NanoTerasu: a new 3 GeV light source in Japan 30m

        NanoTerasu is a 4th generation 3 GeV light source newly constructed in Sendai, Japan. The circumference is 349 m and the natural emittance is 1.1 nm rad, which is realized by a double-double-bend lattice. The commissioning of the storage ring started in June 2023 and the stored current reached 300 mA in November. The beam diagnostic system for NanoTerasu mainly consists of button BPMs to monitor both single-pass and COD beam orbit, a DCCT to monitor the stored current, an X-ray pinhole camera to measure the beam size. To suppress collective instabilities, a transverse bunch-by-bunch feedback (BBF) system is also in use. The BBF system can also measure the betatron tune. In this talk, an overview of the beam commissioning of NanoTerasu, the performance of each beam diagnostic component, and fine-tuning of the electron beam optics will be presented.

        Speaker: Kota Ueshima (National Institutes for Quantum Science and Technology)
      • 11:20
        Design of HEPS beam diagnostics 30m

        HEPS is a fourth generation light source which has horizontal emittance around 34pm.rad and high brilliance photon beam, this ultra-low emittance brings many engineering challenges for beam instrumentation. Self-developed digital BPM electronics and scintillate BLMs contributed more in first turn and day one commissioning. The gird designed by combining carbon fiber and invar alloy have effectively suppress the long drift of the BPM system. Additionally, synchrotron radiation measurement system based on KB mirror has successfully captured the first synchrotron light and provided real-time beam size measurements. This talk will present an overview of beam instrumentation of HEPS.

        Speaker: Yanfeng Sui (Institute of High Energy Physics)
    • 11:50 12:30
      TUB: Overview and Commissioning/Transverse Profile and Emittance Monitors: TUBC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Changbum Kim (Pohang Accelerator Laboratory)
      • 11:50
        Beam diagnostics for CSNS-Ⅱ linac commission and operation 20m

        The China Spallation Neutron Source (CSNS) facility began operation in 2018. By 2020, its accelerator achieved the design power of 100kW and currently operates at a power of 160kW. This year, the power upgrade project (CSNS-Ⅱ) has been launched to meet the growing scientific demands. Our goal is to enhance the accelerator power to 500kW primarily by increasing the beam current. A comprehensive suite of beam diagnostics has been developed to support commissioning and operation of the accelerator at higher intensities. In this paper, we first review the commissioning and operational status of the existing linac, and then outline the new requirements for the linac upgrade.

        Speaker: Jun Peng (Institute of High Energy Physics)
      • 12:10
        Beam size measurement with gratings at BEPCII 20m

        The vertical beam size measurement was carried out at BEPCII using a phase grating and an absorption grating based on the Talbot effect. Due to the partial coherence of the source, coherence length can be calculated by measuring the visibility decay of interferograms recorded at different distances behind gratings. The vertical beam size of 68.19±2μm was obtained based on the relationship between coherence length and source size. A comparison of the vertical emittance derived from grating Talbot method and synchrotron radiation visible light interferometer method was presented to evaluate the method. The vertical emittances from two methods are 1.41nm·rad and 1.40nm·rad respectively. The 0.1% difference indicates the grating Talbot method for beam size measurement is reliable. This technique has great potential in small beam size measurement in the fourth-generation synchrotron radiation light source, considering its small diffraction limitation and simple experimental setups.

        Speaker: Wan Zhang (Chinese Academy of Sciences)
    • 12:30 13:30
      Lunch Break 1h
    • 13:30 14:00
      TUC: Beam Position Monitor: TUCI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Carsten Welsch (The University of Liverpool)
      • 13:30
        Bunch-resolved 3D beam position measurement system and its application in FELiChEM 30m

        A new infrared free-electron laser FEL facility named FELiChEM has been built at University of Science and Technology of China in Hefei. It is a user facility dedicated for energy chemistry research and can deliver the infrared laser in the spectral range of 2.5-200 μm to five research stations. FELiChEM consists of mid-infrared MIR and far-infrared FIR free-electron laser oscillators driven by a 60 MeV linac. The time structure of the electron beam can be easily tuned with the macrobunch width of less than 10 μs macrobunch repetition rate of 1--10 Hz and optional microbunch repetition rate within 238, 119, 59.5 and 29.75 MHz. A 3D bunch-by-bunch position measurement system was developed to monitor not just the average position of the macrobunch but also every individual bunch position in the train. With this toolkits, a significant beam loading effect can be easily observed downstream of the linear accelerator structure, and a strong dispersion effect is observable downstream of the optical oscillator. This diagnostic tool proves to be very useful for analyzing the status of the machine and implementing corresponding optimization measures. This paper will give a brief introduce of the machine, the hardware and software structure of the 3D position measurement system, and its application in machine commissioning and operation.

        Speaker: Xing Yang (University of Science and Technology of China)
    • 14:00 14:40
      TUC: Beam Position Monitor: TUCC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Carsten Welsch (The University of Liverpool)
      • 14:00
        Low frequency position monitoring at the TRIUMF cyclotron injection line 20m

        A new 1mA ion source and a new injection line are presently under construction at TRIUMF for the 500 MeV H- cyclotron. A 300keV ion beam is pulse modulated at the exit of the ion source with a duty cycle varying in the range 1% - 99%. The pulse repetition frequency is around 1kHz and this is the only time varying beam structure available for a substantial fraction of the injection line, till the beam is bunched with an RF-frequency of 23MHz, before being injected to the cyclotron. A set of new diagnostics was developed to support operation of the injection line including the beam position monitoring system operating in the kHz regime. The beam position measurements are based on capacitive pickups and high-impedance electronics to extend the sensitivity towards low frequencies. Details of the system and test measurements will be presented.

        Speaker: Victor Verzilov (TRIUMF)
      • 14:20
        Photon Beam Position Monitor for PLS-II Beamline 20m

        Photon Beam Position Monitor (PBPM) is an effective monitor for the synchrotron radiation position in a beamline of PLS-II and has been used for the insertion device beamline as well as the bending beamline. In this study, we report the operational status of PBPMs for PLS-II. The PBPM feedback system combined with the orbital feedback system maintains the same position of synchrotron radiation in the beamline. In addition, the scanning results of the blade current show that the orbital distortion can be monitored inside the insertion device. This means that the fine alignment of the electron orbit is possible with this result.

        Speaker: Donghyun Song (Pohang Accelerator Laboratory)
    • 14:40 15:10
      Afternoon Coffee Break 30m
    • 15:10 15:40
      TUD: Beam Position Monitor: TUDI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Junxia Wu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 15:10
        Overview of the BPM system for HIAF & CiADS projects 30m

        Both large-scale facilities, CiADS and HIAF, have a SC linac with current range from tens µA to 20 mA demanding a big dynamic for BPM. The HIAF booster ring accelerates all ion beams from MeV/u to GeV/u, resulted an unprecedented challenge to BPM with induced voltage in range of 40 uV – 40 V. Four types of pickups are designed, with the capacitive pickups inside the quadrupoles, the titanium button BPMs inside the CMs with a compact geometry, a complex structure integrated with BPM, a water-cooled niobium ring and vacuum pumps within 300 mm between the CMs. The SiO2 cables under 2 K are developed by the joint R&D with a domestic company. For the synchrotron, a diagonal-cut BPM is designed with a good position linearity, low beam impedance, good vacuum performance up to 5.0E-12 mbar, as well as good mechanical properties with the electrode coaxiality less than 0.2 mm. To obtain precise and reliable position measurement, the dedicated electronics are developed for the position and phase measurement in linac, and the turn-by-turn trajectory and orbit measurement for synchrotrons. Moreover, the non-linearity calibration due to the approaching effect and fringe field is carried out and a high-order polynomial correction algorithm is implemented on FPGA to get the real-time accurate position for beam offsets. Furthermore, both newly developed BPM electronics have self-testing and self-calibration functions. Presently the BPM system is preparing for the installation.

    • 15:40 16:00
      TUD: Beam Position Monitor: TUDC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Junxia Wu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 15:40
        The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline 20m

        The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

        Speaker: Collette Pakuza (European Organization for Nuclear Research)
    • 16:00 17:30
      TUP: Tuesday Poster Session: TUP China Hall 3

      China Hall 3

      • 16:00
        A high-precision low-latency DBPM processor for HALF 1h 30m

        Hefei Advanced Light Facility (HALF) is a fourth-generation vacuum ultraviolet and X-ray diffraction limit synchrotron radiation (DLSR) light source under construction. It is expected to have an ultra-low emittance and an extremely small beam size, which requires high-precision orbit detection and fast feedback control. The processor is the key component of the digital beam position monitor (DBPM) and control system, which is required to provide a submicrometer resolution in beam position measurement with a processing latency of lower than 90 μs. This paper presents the design and testing of a high-precision low-latency DBPM processor. In order to reduce the latency and ensure the high position resolution, a specific higher sampling frequency is chosen to reduce the quantization noise platform of the analog to digital convertor and an optimized low-order filter is adopted. Specialized efforts are devoted to the low jitter sampling clock generation and low noise analog circuit design. Furthermore, a dual-pilot tone structure was employed to compensate the gain variations across the four channels of the beam monitor sensor. The laboratory test results show that the DBPM has a position resolution of better than 400 nm for turn-by-turn acquisition, better than 90 nm for fast acquisition at 20 kHz rate, and better than 20 nm for slow acquisition at 10 Hz rate, with a total latency of less than 80 μs.

        Speaker: Jiajun Qin (University of Science and Technology of China)
      • 16:00
        A project for a Compton photon source at the SKIF synchrotron facility 1h 30m

        SKIF is a synchrotron radiation facility under construction in Novosibirsk.
        Electron beam energy 3 GeV, beam current up to 0.4 A and extremely low horizontal beam emittance 75 pm$\cdot$rad are convenient to make a high-energy photon source at the main storage ring.
        Gamma-photons are obtained using Compton backscattering (inverse Compton scattering) of IR, UV and visible laser radiation.
        Using modern high-power lasers, Compton photons in hundreds-MeV energy range and rates up to 300 MHz can be achieved.
        Also, higher Compton photon energies (up to 2.6 GeV) can be generated using synchrotron radiation reflected towards the electron beam.
        A preferable option for photon monochromatisation is tagging photons by recoil electrons with resolution of 0.6%$\dots$0.8% (or $\sim$2 MeV), which is an advantage of ulta-low electron emittance.
        The discussed Compton source is mainly usable for photonuclear and photohadron processes such as photofission and production of $\pi$, $\eta$, $\Delta$ at nuclei.
        Also nonlinear QED, EM detectors calibration and other applications are in interest.

        Speaker: Viacheslav Kaminskiy (Russian Academy of Sciences)
      • 16:00
        Beam diagnostics systems for the LINAC of LUTF 1h 30m

        " Laboratory for Ultrafast Transient Facility" is organically composed of two major categories of core parts: one is a Ultrafast Transient electron microscope cluster; the other is a Ultrafast Transient synchrotron radiation device that provides ultraviolet to X-rays. The first stage of synchrotron radiation device includes a 0.5 GeV linear accelerator as full energy injector, a high-current storage ring, and a beam line. For the construction of the linear accelerator beam diagnostics system, the main focus is on the reliability and maintainability of the system. The system mainly includes beam position measurement system , bunch charge measurement system and beam profile measurement system; the article will mainly introduce the composition and design of these systems.

        Speaker: Ming Meng (Chongqing University)
      • 16:00
        Beam position monitors for the HEPS 1h 30m

        At the High Energy Photon Source (HEPS), a high orbital stability of typically 10 % of the beam size and angular divergence must be achieved, which implies that the beam orbit must be stabilized to the sub-micrometer level. A button and stripline beam position monitor (BPM) were designed based on the analytical formulas and CST simulations results. The results of electromagnetic field simulations revealed how various mechanical errors, such as button size and location accuracy, as well as the related button capacitance, exert different influences on the beam position measurement. The performance of an actual BPM pickup was measured, along with an assessment of the error on the beam position measurement. Additionally, a wakefield analysis, including an investigation of trapped resonant modes and related thermal deformation, was conducted. The characteristic impedances of the stripline were designed to be 50 Ω and confirmed by measurements. The position sensitivity, position resolution, capacitance and the electro-mechanical offsets were measured using the Lambertson method, and the calibration coefficients were measured using a stretched wire.Various problems that arise during the processing and installation process will also be introduced.

        Speaker: Jun He (Institute of High Energy Physics)
      • 16:00
        BPM-based electron beam trajectory optimization at PITZ 1h 30m

        The Photo Injector Test Facility at DESY in Zeuthen (PITZ) has been developing high brightness electron sources for the XUV and soft X-ray free-electron facility (FLASH) and the European X-Ray Free Electron Laser facility (EuXFEL) at Hamburg. Its research fields have expanded into applications in recent years like THz FELs, and radiation biology for cancer treatment. Since the applications require varying beam parameters(bunch charge from <10 pC up to 4 nC, momentum from 6 MeV/c up to 22 MeV/c), a robust and reliable beam trajectory recovery and correction algorithm has been developed, which allows to fast establish and/or recover a quasi-optimal performance for different experiments. One of the key functions is to make certain quadrupoles steering-free, which is critical for THz FELs and radiation experiments. It also provides a detailed beam trajectory overview by fitting the beam positions measured at beam position monitors (BPMs) using the response matrices and with the earth magnetic fields (EMF) considered, providing a deeper understanding of the intermediate beam trajectory and enabling efficient corrections. In this poster, the analytical model, the robustness test and the experimental performance of this tool will be presented.

        Speakers: Dr Dmytro Dmytriiev (Deutsches Elektronen-Synchrotron DESY at Zeuthen), Xiangkun Li (Deutsches Elektronen-Synchrotron DESY at Zeuthen)
      • 16:00
        Bunch-by-bunch beam position measurements at PETRA III 1h 30m

        The PETRA IV project is set to enhance the current PETRA III synchrotron into an ultra-low-emittance source. The reduced emittance will impose stringent requirements on machine stability and operation. In order to cope with these requirements, bunch-by-bunch information is required from most of the monitor systems. For precise monitoring of beam position and charge, the Libera Digit 500 instrument was tested as a readout electronics for BPMs at the existing machine PETRA III. This system features four channels with a 500 MHz sampling rate, synchronized with the accelerator's RF, enabling observation of beam properties with a bunch-by-bunch resolution, thus facilitating a more comprehensive understanding of beam behavior. This contribution provides an overview of the latest beam measurements at the single bunch level, allowing observation of beam oscillations and injection dynamics.

        Speaker: Carolina Alvarez de Santiago (LPC Caen)
      • 16:00
        Cavity Beam Position Monitors pulse Injection source 1h 30m

        The Cavity Beam Position Monitor (CBPM) system at Accelerator Test Facil- ity 2 (ATF2, KEK, Japan) operates with attenuation at a reduced 200 nm (vs measured 20-30 nm) resolution to cope with CBPM to magnet misalignment. In addition, CBPMs need regular calibrations to maintain their performance. To address these limitations, a pulse injection system is under development. This system aims to compensate for static offsets by injecting an anti-phase replica of the average beam signal directly into the sensor cavities. The same signal can provide a calibration tone for the whole processing chain and eliminate lengthy beam-based calibrations. Proof of principle tests for such a system have been conducted in December 2023. In this paper, we report on the results of the first beam test, discuss the technical challenges and provide a preliminary hardware specification for future experiments.

        Speaker: Max Bosman (Royal Holloway, University of London)
      • 16:00
        Certification testing of prototype superconducting quarter-wave and half-wave resonators for HIAF 1h 30m

        The 81.25 MHz quarter-wave resonator (QWR) and 162.5 MHz half-wave resonator (HWR) are selected as the main accelerating cavities for the superconducting ion linac of the High Intensity heavy-ion Accelerator Facility (HIAF) at the Institute of Modern Physics (IMP). Six QWR007 (βopt = 0.07) cavities and eight HWR015 (βopt = 0.15) cavities have been fabricated before the mass production to verify the design and production quality control. Two cavities of the both types have been random chosen to surface processing and vertical testing for performance validating before welding helium vessel. In this paper, the development of SRF cavity for HIAF will be addressed, which including the fabrication, surface processing and vertical testing results. The achieved gradients for both cavities have exceeded 60%~100% of requiring operation gradients. The Q0 of both types cavities have met the 2 K operation requirement too. These results inspired to push the cavity production for the HIAF project forward to the mass production stage.

        Speaker: Mr Zehua Liang (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Cherenkov Diffraction Radiation Beam Position studies at Diamond Light Source 1h 30m

        This paper will show beam position studies performed using a Cherenkov Diffraction Radiation (ChDR) based Beam Position Monitor (BPM) at Diamond Light Source (DLS). Displaying the characterisation of the BPM using the 3 GeV electron beam at DLS and comparing the effectiveness of this prototype to an existing Inductive Beam Position Monitor (IBPM) in use in the DLS Booster To Storage (BTS) transfer line. The functionality of the BPM is explored, utilising both wideband and narrowband ChDR emission with the application of filters to the ChDR detection system.

        Speaker: Lorraine Bobb (Diamond Light Source Ltd)
      • 16:00
        Commissioning of the slow extraction beam instrumentation at PREF 1h 30m

        The Proton Radiation Effects Facility (PREF) aiming for the displacement damage effect research was proposed by XTIPC (Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences) in 2018. The facility was designed and constructed by IMP (Institute of Modern Physics, Chinese Academy of Sciences). The beam commissioning of PREF had been started since August to September of 2023. Four types of instruments, scintillation screen, Faraday cup, scintillator and ionization chamber are implemented for the proton beam profile, intensity, position, efficiency, spill structure. With the beam instruments, the machine reached nearly 95% slow extraction efficiency for all energies from 10 to 60 MeV, 5$\times10^{10}$ particle per second (ppp), 2$\times$2 cm² up to 20$\times$20 cm² scanning area.

        Speaker: Tong Liu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Current status of the manufacturing and testing of the BPM electronics for ELETTRA 2.0 1h 30m

        In this paper we are presenting the status of the partnership between Instrumentation Technologies and Elettra Sincrotrone Trieste for the realization of 200 BPM electronics for ELETTRA 2.0. Last year, 200 Pilot Tone Front-End (PTFE) units were successfully developed and produced. During the present year, 100 Digital Acquisition platforms, each one used to digitize and process the signals from two BPM pickups, are in production after the successful pre-series tests.
        Elettra Sincrotrone Trieste was more involved in concept design, prototype development, and firmware programming, while Instrumentation Technologies was focused on design for manufacturing, implemented rigorous testing procedures, and handled the production.
        During the project, it was also necessary to overcome a period of material shortages, particularly for the chips used in the digital part. Testing during the pre-series and series production phases ensured that each unit met the desired performance criteria necessary for stabilizing long-term measurement drifts in BPM systems. Additional units were produced to account for potential failures and performance variations, ensuring that all units delivered performed to specification.

        Speaker: Manuel Cargnelutti (Instrumentation Technologies)
      • 16:00
        Design and construction status of the diagnostic system for the Compact LAser Plasma Accelerator II 1h 30m

        Over the past two decades, laser-driven proton radiotherapy devices have garnered significant attention among novel accelerator technologies, due to their high acceleration gradient. Peking University is engaged in the construction and development of CLAPA-II (the Compact LAser Plasma Accelerator II), a proton therapy facility which utilizes a laser-plasma acceleration scheme. This facility comprises two horizontal and vertical beam transmission lines, operating at a repetition rate of 1Hz, capable of delivering 10^8-10^10 protons per second. We have implemented both interceptor and non-interceptor detectors for precise measurements of proton beam. Notably, this is the first instance where an ionization chamber and cavity BPM have been integrated into a laser proton therapy accelerator. To validate the performance of our beam diagnostic system, we have established an offline test platform that simulates the laser proton beam. The results indicate that the offline test resolution of the cavity BPM has achieved 0.2μm in the range of ±3mm. Furthermore, we explored the absolute collection efficiency and particle recombination factor of ionization chamber with ultra-high dose rate proton beams, leveraging the laser-driven ultrashort electron beam generated by Peking University's CLAPA-I facility. This paper provides an overview of the beam diagnosis system's overall layout, accompanied by a detailed description of the detector design and corresponding measurement results.

        Speaker: Kai Wang (Peking University)
      • 16:00
        Design and deployment of an in-vacuum Electro-Optic BPM at the CERN SPS 1h 30m

        Accurate monitoring and control of charged particle beams at the HL-LHC demands the development of new beam diagnostics tools. This poster provides an overview of the electro-optic beam position monitor (EO-BPM), currently taking measurements at CERN's SPS. This device uses the Pockels effect to monitor the transverse position and instabilities in the particle beam. Comprising of a laser source, electro-optic crystal, optical system, and a fast photodetector, the EO-BPM operates by generating a modulated optical signal directly linked to the propagating electric field of the beam.

        The EO-BPM is designed as a self containing button with fibre-coupled laser connected to the crystal inside and a fibre coupled Mach-Zehnder interferometer yielding sum and difference signals on the outside. A segment of the SPS beam pipe is fitted with a mount to connect the button, allowing the electric field induced by the particle beam to be captured and transferred to the electro-optic crystal.
        The goal is to gain insight into the transverse position along the bunch and the identification of intra-bunch instabilities, contributing to precision in beam monitoring and control.

        Speaker: Max Bosman (Royal Holloway, University of London)
      • 16:00
        Design of a stripline BPM for CSNS-II injection upgrade 1h 30m

        The CSNS accelerator complex is upgrading the injection area to improve the beam-loss control during beam injection and acceleration in the Rapid Cycling Synchrotron. At CSNS, the linac beam energy will be increased from 80MeV to 300MeV employing a new superconducting accelerating section, and the beam power at the spallation target will be 500kW. To accomplish these requirements, a stripline-type BPM has been designed with a large aperture and 50 Ω stripline electrodes. This BPM has an inner diameter of 52 mm and is used to detect the beam with a current of 10-30 mA and a pulse width of 100-500us. Several geometrical and electrical parameters have been optimized with numerical simulation. This paper will describe the design and optimization of the stripline-type BPM in detail, and simulation results are discussed.

        Speaker: Biao Zhang (Institute of High Energy Physics)
      • 16:00
        Design of Beam Position Monitor of Wuhan Photon Source 1h 30m

        Wuhan Photon Source (WHPS), as a fourth-generation synchronous light source, imposes stringent requirements on the resolution and longitudinal coupling impedance of the Beam Position Monitor (BPM). To address the need for beam current monitoring in its 1.5 GeV diffraction-limited storage ring, an optimized design scheme for button BPM is proposed. Additionally, the structure of the BPM feedthrough is enhanced, and a detailed investiga-tion into the impact of various materials on the longitudi-nal coupling impedance of the BPM is conducted. These findings serve as a valuable reference for the future de-sign of similar BPM systems.

        Speaker: Mr Haoyu Dong (Huazhong University of Science and Technology)
      • 16:00
        Design of beam position monitoring interlocking protection system 1h 30m

        The machine protection system guarantees the safe operation of the HIAF (High Intensity heavy-ion Accelerator Facility) in different operating modes and also prevents damage to the online equipment in the event of a failure. Beam current data such as beam current position and phase is an important basis for analysing and diagnosing accelerator faults. In this paper, the authors designed the beam position and phase interlock monitoring system. The system is based on circular buffer and AXI4 protocol to realize the interaction of interlock data and locking of interlock status. At the same time, the system uses memory mapping to save the interlock beam data. Laboratory tests show that the system could save the beam position, beam phase, SUM signals and amplitude of sensed signal per probe path during interlocking before and after 8ms and latch the interlock status of 25 channels. The system was deployed at the CAFe-LINAC gas pedal in March 2024 to complete online measurements.

        Speaker: Ruixia Tian (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Design of button beam position monitor for the ILSF booster 1h 30m

        The Iranian Light Source Facility Booster is under design with a 504 m circumference and will accelerate the electron bunches from 150 MeV to 3 GeV. the 50 button-type beam position monitors (BPMs) are considered the non-destructive tools to measure the beam position in the ILSF booster. In this paper, the design of the BPM for the ILSF booster is studied. The BPM blocks have 4 buttons (electrodes) that are placed at 45 degrees to the beam axis. to choose the best geometry, The BPMs with different button diameters and gaps are simulated by the CST Microwave Studio and BpmLab.

        Speaker: Samira Mohammadi Alamouti (Iranian Light Source Facility)
      • 16:00
        Design of the BPM button for ALBA II 1h 30m

        As many other light sources, ALBA is also going through an upgrade phase leading to ALBA II. In this context, new Beam Position Monitors (BPMs) have to be designed to fit the reduced vacuum chamber. The buttons and the block were designed to be as compact as possible minimizing the impedance to avoid overheat and maintaining a good signal level. Different shapes and materials were simulated and the best were selected to be produced as prototype. In this proceeding, we present the design process and the simulations that lead to the ALBA II BPM button design.

        Speaker: Ubaldo Iriso (ALBA-CELLS Synchrotron)
      • 16:00
        Design of X-ray ionization beam profile monitor for Korea-4GSR 1h 30m

        The Insertion Device (ID) photon beam of a synchrotron can be contaminated with radiation from upstream and downstream bending magnets, causing position measurement errors in blade-type monitors. Beamlines of the low emittance storage ring are particularly sensitive to photon beam position variations, requiring more accurate measurements. To address this, we designed an ionization profile monitor to non-destructively measure the profile and position of the white undulator beam at Korea-4GSR without contamination. Leveraging the relatively large active area of readout devices suitable for small emittance beams we have designed a 1:1 mapping field to defocus photo-ions. Given that the defocusing field can induce errors due to vertical position, we propose a calibration method and validate it using particle tracking simulation.

        Speaker: Woojin Song (Pohang University of Science and Technology)
      • 16:00
        Designed and implemented 128-channel readout electronics based on the CFC 1h 30m

        To convert weak current signals into voltage pulse signals proportionally, a 128-channel readout electronics system is developed. The front-end analogue circuits of this readout electronics system are designed based on the Charge to Frequency Converter (CFC) circuit structure, and the back-end digital board processes the voltage pulse signals. After the performance test in the laboratory and the beam test in PREF, This system can proportionally convert currents from 1 pA to 1 μA into voltage pulse signals with an input dynamic range of 120 dB. The maximum nonlinear error does not exceed ±10%, and the system’s resolution is less than 100 fA. The isolation between the adjacent channels is lower than -114 dB. The system is used not only for beam profile monitoring, but also for the flatness, symmetries and scanning uniformity measurements of slow-extraction beams. The system is of great value in the field of weak beam profile measurements.

        Speaker: Xiaoxuan Qiu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Developing a new beam position monitor electronics for HIPA, The PSI High Intensity Proton Accelerator 1h 30m

        The High Intensity Proton Accelerator (HIPA) at PSI presently has an RF beam position monitor (BPM) system based on 20 year old Xilinx Virtex-2 Pro Systems-on-Chip (SoC), using application-specific integrated circuits (ASICS) for direct digital downconverters. For the planned upgrade of the electronics as well as for new HIPA projects, we started the development of a new HIPA BPM electronics, using a generic electronics platform called "DBPM3" that is already being used for SwissFEL and SLS 2.0 electron BPM systems. In this contribution, first test results of a DBPM3-based HIPA BPM electronics prototype are presented, including a comparison with the present electronics.

        Speaker: Pascal Huber (Paul Scherrer Institute)
      • 16:00
        Development and performance evaluation of the cavity BPM system for SHINE 1h 30m

        The Shanghai high repetition rate XFEL and extreme light facility (SHINE) under construction is designed as one of the most advanced FEL facilities in the world, which will produce coherent x-rays with wavelengths from 0.05 to 3 nm and maximum repetition rate of 1MHz. To achieve precise beam trajectory measurement and stable alignment of the electron and photo beams in the undulator, the cavity beam position monitors (CBPM) including beam diameters of 35mm in LINAC and Bunch distribution section and 8mm in undulator have been designed and developed for the SHINE. The requirement of the transverse position resolution is better than 1μm and 200 nm for a single bunch of 100 pC, respectively. In this paper, we present the design of the cavity BPM system and the processing of the key equipment. The beam test bench has been established at the Shanghai Soft X-ray FEL facility (SXFEL), and preliminary beam experiments indicate that, with the bunch charge about 100pC, the position resolution of CBPM-35mm and CBPM-8mm is better than 330 nm and 70 nm, respectively.

        Speaker: Jian Chen (Shanghai Synchrotron Radiation Facility)
      • 16:00
        Development of a beam position monitor for MYRRHA high energy beams 1h 30m

        MYRRHA (Multi-Purpose Hybrid Research Reactor for High-Tech Applications) aims to demonstrate the feasibility of high-level nuclear waste transmutation at industrial scale. MYRRHA Facility aims to accelerate 4 mA proton beam up to 600 MeV. The accurate tuning of LINAC is essential for the operation of MYRRHA and requires measurement of the beam transverse position and shape, the phase of the beam with respect to the radiofrequency voltage with the help of Beam Position Monitor (BPM) system. MYRRHA is divided in two phases, the first phase, called MINERVA, includes several sections allowing beam acceleration up to 100 MeV. the second phase includes a High Energy Beam Transport (HEBT) line up to 600MeV. A BPM prototype was realized for the HEBT line. This paper addresses the design, realization, and calibration of this BPMs and its associated electronics. The characterization of the beam shape is performed by means of a test bench allowing a position mapping with a resolution of 0.02 mm.

        Speaker: Dr Sidi Mohammed Ben Abdillah (Université Paris-Saclay, CNRS/IN2P3, IJCLab)
      • 16:00
        Development of an automatic calibration system for BPM 1h 30m

        Beam position monitor(BPM) is used to measure the horizontal and vertical positions of the beam in the vacuum pip. Before online installation, it usually needs to be calibration. High Intensity Heavy-ion Accelerator Facility(HIAF) and China initiative Accelerator Driven System(CiADS) will need a large number of BPM, so it is a great challenge for BPM calibration work. In order to complete this work efficiently and accurately, this research designs and develops an automatic BPM calibration system.
        The hardware of this BPM calibration system consists of 4 major sections, they are calibration platform equipment, precise motion control device, signal processing electronics and industrial computer. The control software was programmed by C to realize automatic calibration functions based on EPICS. A high-order fitting algorithm programmed by python used to solve the problem of smaller linear range of the capacitive BPM. It significantly improves the accuracy of position measurement after calibration.

        Speaker: Li Li (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Development of digital beam position monitor for HEPS 1h 30m

        High Energy Photon Source (HEPS) is a proposed new generation light source with a beam energy of 6 GeV, high brightness, and ultra-low beam emittance. An RF BPM has been designed at IHEP as part of an R&D program to meet the requirements of both the injection system and storage ring. The RF BPM architecture consists of an Analog Front-End (AFE) board and a Digital Front-End board (DFE) based on a custom platform. In this paper, we present the overall architecture of the RF BPM electronics system and the performance evaluation of the BPM processor, including beam current, filling pattern, and position measurement resolution as a function of the beam current.

        Speaker: Mr Yaoyao Du (Institute of High Energy Physics)
      • 16:00
        Development of high-precision beam position monitor for the Korean 4GSR project 1h 30m

        The Korean 4GSR project is currently under construction in Ochang, South Korea, with the aim of achieving first beam commissioning in 2027. Designed to achieve an emittance approximately 100 times smaller than that of third-generation synchrotron radiation storage rings, the project requires the development of several high-precision beam diagnostic devices. In particular, the beam position monitor (BPM) is aimed at reducing longitudinal wake impedance to suppress heating and beam instability. For this purpose, two types of 4GSR BPM pick-up antennas have been developed. The first utilizes a SiO2 glass insulator, while the second is designed in a cone shape using Al2O3. The differences and advantages of the two designs are explained, and the performance obtained through actual beam tests will be described. This presentation will provide an overview of the current development status of the beam position monitor developed for the 4GSR project, including details on the approximate configuration of the 4GSR BPM system.

        Speaker: Si-Won Jang (Pohang Accelerator Laboratory)
      • 16:00
        Development of multi-channel time-division multiplexing RF signal conditioning front-end for CAFe2 BPM system 1h 30m

        The construction of China Accelerator Facility for Superheavy Elements(CAFe2) is advancing based on Chinese ADS Front-end Demo Linac(CAFe). However, the original Beam Position Monitor(BPM) read-out electronics of CAFe could not meet the requirements of the CAFe2 BPM probes in terms of quantity and the measurement demands of low-intensity heavy ion beams. In response to this challenge, a high-speed RF switch array supporting multi-channel multiplexing, adjustable gain and filtering was developed. This array served as the RF signal conditioning front-end, together with the RF front-end and digital signal processing platform, to constitute a complete BPM read-out electronics. Laboratory testing validated the feasibility of the high-speed RF switch array and the entire read-out electronics. Compared with traditional read-out electronics, the read-out electronics equipped with the high-speed RF switch array enables the measurement of 32 signals from 8 BPM probes. This approach significantly improves the system's integration and reusability, while offers an efficient solution for implementing multi-channel time-division multiplexing measurement under different beam intensities and operating frequencies. Additionally, by simultaneously accessing signals from multiple BPM probes, this system better supports differential measurement. Overall, the high-speed RF switch array not only meets the requirements of CAFe2 but is also applicable for other accelerators with multiple BPM probes.

        Speaker: Pengfei Deng (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Development of stripline-type beam position monitor system for CSNS-II 1h 30m

        As part of the CSNS-II upgrade, the H- LINAC beam energy will be increased from 80 MeV to 300 MeV using superconducting cavities. To accurately measure beam position, phase, and energy, stripline-type Beam Position Monitors (BPM) are essential. The shorted-type stripline BPM was chosen for this upgrade due to its excellent S/N ratio and rigid structure. As space is limited in the LINAC's SC section, the BPMs must be embedded in the quadrupole magnet. Two prototypes, with inner diameters of 50 mm and 96 mm, were designed using numerical simulation codes and manufactured for beam testing. This paper will detail the simulation, design, and beam test results of the prototype BPMs for CSNS-II.

        Speaker: Muhammad Abdul Rehman (Institute of High Energy Physics)
      • 16:00
        Development of the beam diagnostic system of the HUST-PTF transport lines 1h 30m

        Huazhong University of Science and Technology is building a cyclotron-based Proton Therapy Facility (HUST-PTF). The facility mainly consists of a 240MeV superconducting cyclotron, a beam transport line, a fixed treatment room and two rotational treatment rooms. HUST-PTF uses three kinds of detectors, Scintillation, Faraday cup and ionization chamber, for the beam param-eter measurements. In terms of structure, the HUST PTF beam diagnostic system is built according to the standard distributed three-layer structure, which is divided into hardware device layer, data processing layer and GUI layer. Different protocols are used to communicate be-tween the three layers, which can improve reliability and expand flexibly in each layer.

        Speaker: Mr Shaokun Zhou (Huazhong University of Science and Technology)
      • 16:00
        Development status of the BPM system for the SPring-8-II storage ring 1h 30m

        We are developing a BPM system for the 6 GeV fourth-generation light source, SPring-8-II, which is a renewal of the third-generation light source, SPring-8. The new storage ring will be equipped with 340 button-type BPMs. BPM heads with molybdenum button electrodes have been designed to achieve the position sensitivity coefficients required for SPring-8-II as well as minimal beam impedance and heat dissipation. The BPM heads for the vacuum chambers of the prototype cell are currently being fabricated to validate the mechanical design. As for radiation-resistant signal cables, PEEK-insulated semi-rigid cables will be used for connection to the BPM head, and polyethylene-insulated corrugated cables relay from the girder side to the readout electronics. High-precision and stable readout electronics consist of RF front-end boards and high-speed digitizer boards based on the MTCA.4 standard. The initial batch of electronics has already been installed to replace the obsolete single-pass BPM system of the current SPring-8, and the performance evaluation is in progress. In this presentation, we will report the overview and the development status of the SPring-8-II BPM system.

        Speaker: Mr Hirokazu Maesaka (RIKEN SPring-8 Center)
      • 16:00
        Diagnostics beamline for the superconducting RF photoinjector test stand at DESY 1h 30m

        For future continuous wave (CW) and high-duty-cycle operation of the European XFEL, research and development of the DESY L-band CW photoinjector is ongoing. The implementation of a superconducting radio frequency (SRF) gun operated at 1.3 GHz with a copper photocathode is the baseline option. The electron beam quality, in particular the slice emittance, produced by this injector is key for the successful operation of the free-electron laser. In order to study the beam quality and stability of operation, a dedicated test stand and diagnostics beamline is being developed at DESY. Here, we present an overview of the foreseen diagnostic components and methods at the SRF CW photoinjector test stand.

        Speaker: Sonja Jaster-Merz (Deutsches Elektronen-Synchrotron)
      • 16:00
        Electron bunch position determination using a high frequency button beam position monitor in the AWAKE facility 1h 30m

        The AWAKE facility uses novel proton beam-driven plasma wakefields to accelerate electron bunches over 10m of Rubidium plasma. Precise monitoring of 2 diverse beam types necessitates an electron beam position monitor (BPM) working in a frequency regime of tens of GHz. A high frequency conical button-style BPM with a working regime of up to 40 GHz has been investigated as a way to discriminate the electromagnetic fields of 19 MeV, 4 ps electron bunches propagating spatially and temporally together with a 400 GeV, 170 ps proton bunch in the AWAKE common beamline. The sensitivity of the HF BPM to the electron beam position is determined under various beam conditions, with both electrons and protons, and integration with a TRIUMF front-end is discussed.

        Speaker: Bethany Spear (John Adams Institute)
      • 16:00
        Electronic test bench for the validation of myrrha BPM ac-quisition systems 1h 30m

        MYRRHA (Multi-Purpose Hybrid Research Reactor for High-Tech Applications) aims to demonstrate the feasibility of high-level nuclear waste transmutation at industrial scale. MYRRHA Facility aims to accelerate 4 mA proton beam up to 600 MeV.
        Beam Position monitors are key elements in many accelerators. for instance, once BPMs are installed along a linear accelerator or a storage ring, they remain inaccessible for any validation of updated or rejuvenated electronics. this paper addresses this issue with the realisation of an electronic test bench simulating the outputs signals of BPM electrodes for a given beam energy, phase and position. the bench is realized for MYRRHA BPMs and it offers simulated beams with a position precision down to 50μm and phase precision down to 0.5° on a wide range.

        Speaker: Dr Sidi Mohammed Ben Abdillah (Université Paris-Saclay, CNRS/IN2P3, IJCLab)
      • 16:00
        Estimation of beam transverse parameters through a multimode fiber using deep learning 1h 30m

        In response to CERN's need for alternative imaging solutions of scintillating screens due to the discontinuation of radiation-hardened VIDICON tubes, the single large-core multimode fiber (MMF) has been identified as a potential medium to transmit image signals to a CMOS camera situated away from radiation-prone areas. However, significant challenges in image distortion at the fiber's output end complicate the reconstruction of the original beam distribution.
        To address this, a novel machine learning-based approach was introduced that utilizes a deep convolutional encoder-regressor network. It first compresses the fiber image into a latent space. Subsequently, a fully connected regression network directly estimates the beam parameters, such as centroids and widths, from the encoder output without the need to reconstruct the detailed image. This contribution will showcase an end-to-end system capable of estimating transverse beam parameters from the MMF output speckle patterns. Offering a safe, camera-preserving solution for beam imaging in high-radiation environments.

        Speaker: Hao Zhang (Cockcroft Institute)
      • 16:00
        Features of non-destructive beam instrumentation at the INR RAS high-intensity hydrogen ions linac 1h 30m

        The linac of INR RAS is а high-intensity accelerator of protons and H-minus ions, which is used for a complex of neutron sources, isotope production, proton irradiation and investigations in proton flash therapy. A non-destructive beam instrumentation plays a key role in the linac tuning. The general peculiarity of this multi-component system is that all detectors are home-made devices with a wide operation range and can be used at different ion linacs with a minimum adaptation to beam parameters. Beam current transformers for standard and in-air measurements, resonance and capacitive position and phase monitors, BIF-monitor for 1D and beam cross-section monitor for 2D non-destructive profile diagnostics. Different operation features and manufacturing peculiarities are presented in this paper. Results of implementation, operation and continuous upgrade are described. Also easily scalable typical designs of some detectors are discussed.

        Speaker: Sergei Gavrilov (Russian Academy of Sciences)
      • 16:00
        First beam commissioning and beam quality optimization of the CiADS front end 1h 30m

        The China Initiative Accelerator Driven System (CiADS), a multi-purpose facility driven by a 500 MeV superconducting RF linac, is currently under construction in Huizhou, Guangdong. In order to ensure the stable operation of the superconducting linac, we conducted optimization research on the beam quality in the front-end section of CiADS. By using the point scraping method, part of the beam halo particles are removed in advance at the entrance of the LEBT, avoiding the generation of beam halo particles. On the other hand, since the beam extracted from the ECRIS contains a portion of $H^{2+}$ and $H^{3+}$particles, impurity particles may lead to a decrease in the transmission efficiency of downstream accelerators. By separating the mixed beam, it is possible to measure the proportion and phase space distribution of the mixed beam at the exit of the ion source, thereby achieving accurate measurement of the proton beam. This paper mainly outlines the first beam commissioning of CiADS Front end. Additionally, the effectiveness of the point scraping method has been verified through transverse emittance measurement, and the proportion and phase space distribution of the mixed beam was measured. Furthermore, the stability of the ion source was tested, and the centroid shift of the ion source extracted beam was measured.

        Speaker: Duanyang Jia (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        First experiences with the new Pilot-Tone-based eBPM system in Elettra Storage Ring 1h 30m

        This paper presents the first experiences acquired with the new eBPM system based on pilot tone compensation, developed for Elettra 2.0. After the successful delivery of seven complete systems, belonging to a pre-series production within the signed partnership with Instrumentation Technologies, we started their integration in the current machine, in order to gain experience and develop all the functionalities required for the future commissioning of the new accelerator, scheduled for 2026.
        To do so, an entire section of Elettra storage ring has been equipped with the new systems: eight Libera Electron units have been replaced by eight Pilot Tone Front End (PTFE) and four digital platforms (DAQ10SX).
        Tests were carried out during dedicated machine shifts, focusing on integration with the new global orbit feedback at different data rates (10 kHz, 100 kHz and turn-by-turn), with and without pilot tone compensation. Nevertheless, triggered acquisitions were made in order to test first turn capability of the system. Another unit has been attached to a pair of spare pick-ups (low-gap BPMs), in order to continue the development of new features and to provide different types of data (raw ADC data, turn-by-turn calculated positions, etc.) for machine physics studies, even during user-dedicated shifts.

        Speaker: Dr Gabriele Brajnik (Elettra-Sincrotrone Trieste S.C.p.A.)
      • 16:00
        First results of INR RAS linac timing system upgrade 1h 30m

        INR RAS linac was developed in late 1970s and build during 1980s. Its timing system is based on the fifty years old technologies and requires full upgrade due to system stability decrease, lack of spare parts, progressing hardware degradation and increase in RF jamming. Moreover, the timing system upgrade should be done without additional accelerator complex shutdowns. In this paper a project of a new timing system that fulfills all requirements is presented. Various features and production peculiarities of the new timing system hardware and software are described. Results of the implementation of new system first parts and its commissioning and plans for future upgrade are discussed.

        Speaker: Alexander Titov (Institute for Nuclear Research of the Russian Academy of Sciences, Moscow, Russia)
      • 16:00
        Heterodyne Near-Field Speckle simulations using SRW at the ALBA FE21 1h 30m

        Several experiments were done to measure the transverse beam size at the NCD ALBA beamline using the Heterodyne Near Field Speckles (HNFS) technique. Inside the FCC collaboration, it was decided to move these experiments to the ALBA Front End 21, where currently an x-ray pinhole camera is working since 2021. The goal is that the two measurement techniques can work alternatively and measure the electron beamsize of the same source point, so that a direct comparison between both techniques can be done. This paper reports the SRW simulations performed in order to investigate the feasibility of the HNFS experiments at this new location. In particular, it focuses on the effect of the dipole radiation and the design of the high energy and high bandwidth monochromator requirements.

        Speaker: Ubaldo Iriso (ALBA-CELLS Synchrotron)
      • 16:00
        High-quality feedthrough developments for beam detectors 1h 30m

        Feedthroughs have been used for different accelerator detectors, such as BPM, BAM, CBPM, ACCT, and the RF cavities etc. that are used to test the beam properties and RF cavity signals. For this purpose, large bandwidth with low transfer loss is required. The long-life and high-stability are also needed. The SMA-type and N-type feedthroughs are developed. The bandwidth of the SMA-type is up to 20 GHz, and that of the N-type up to 13 GHz with low transfer loss. Those feedthroughs have used in the strip-BPM, button-BPM, and CBPM etc..

        Speaker: Sun An (Najing Institute of Proton Source Technology)
      • 16:00
        High-sensitivity RF direct sampling processor redefines the beam diagnostic system 1h 30m

        RF direct sampling and processing of beam signals has always been the goal pursued in beam diagnostic systems. Now it’s time to make it happen. For the first time, a high-sensitivity RF direct sampling processor has been developed for C-band cavity pickups in SHINE/SXFEL. It redefines the beam diagnostic system. There is no longer a need for complex analog down-conversion modules in traditional cavity BPM/BAM systems. In addition, the processor can simultaneously meet the signal processing needs of different cavities with a center frequency below 6 GHz. Obviously, the RF direct sampling processor greatly reduces the complexity and costs of the system, shows great versatility. Meanwhile, compared to the down-conversion electronics, this processor demonstrates much higher sensitivity (twice) due to a significant reduction in analog components. The processor also has a huge advantage in other beam diagnostics because of its wide bandwidth and high sampling rate, such as bunch-by-bunch measurement and feedback system on synchrotron radiation facility. Now it's time to massively apply the RF direct sampling processor to promote the development of beam diagnostic technology.

        Speaker: Longwei Lai (Shanghai Advanced Research Institute)
      • 16:00
        Innovative transverse position measurement method based on precise signal phase detection and its experimental validation 1h 30m

        The accurate measurement of the transverse position of a beam is crucial in particle accelerators, as it plays a key role in determining the beam parameters. Existing methods for beam position measurement rely on the detection of image currents induced on electrodes or the narrow-band wake field excited by the beam passing through a cavity-type structure. These methods have some limitations. Indirectly measuring the multiple pa rameters is computationally complex and requires external calibration to determine the system parameters in advance, and the utilization of the beam signal information is incomplete. In this work, a novel method that measures the absolute electron beam transverse positionis proposed. By utilizing the geometric relationship between the center position of the measured electron beam and multiple detection electrodes, as well as analyzing the differences in the arrival times of the beam signals detected by these electrodes, the absolute transverse position of the electron beam crossing the electrode plane can be calculated. This method has features such as absolute position measurement, position sensitivity coefficient independent of the vacuum chamber aperture, and no requirement for symmetrical detector electrode layout. The feasibility of this method is validated through numerical simulation and beam experiments.

        Speaker: Xing Yang (University of Science and Technology of China)
      • 16:00
        Intermediate stage amplifier electronics for HIAF ring beam diagnostic system 1h 30m

        This article introduces the intermediate stage amplifier electronics for the HIAF Ring beam diagnostic system, it has intermediate stage amplifier, high-impedance preamplifier gain switching control, self-check, fiber communication, and enthernet communication functions. The intermediate stage amplifier has 4 channels, each channel has three gain states: 20dB, 0dB, -20dB, combining with preamplifier which has 2 gain states (30dB and 0 dB), 6 gain states can be got to make the signal magnitude input to BPM electronics falls in optimal range for ADC sampling as possible. According to simulation result, the maximum voltage of BPM induction signal could exceed 40V with 50Ω impedance, so a low reflection low-pass filter is placed before amplifier to avoid the devices damage and signal reflection, the filter bandwidth is 10MHz and it can attenuate the peak voltage by half at shortest beam signal while S11<-25dB. Electronics integrates two 8-pole LEMO connectors as control outputs to control the preamplifier gain state. The self-check signal is generated by an active crystal oscillator, and injected into 4 channels by 4 drivers. Optoelectronic converter, electro-optic converter and ethernet module are integrated to achieve remote communication. All control logic and communication is realized by an Actel FPGA chip.

        Speaker: Shangshang LU (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Maximum entropy tomography of 4D transverse phase space distributions using 2D measurement results 1h 30m

        Obtaining the complete distribution of a beam in high-dimensional phase space is crucial for predicting and controlling beam evolution. Based on the theory of maximum entropy tomography, we developed an algorithm for reconstructing the four-dimensional (4D) transverse phase space distribution. Our algorithm can take any number of 2D linear projections as constraints, and iteratively converges to the unique numerical solution which is the maximum-entropy distribution satisfying the constraints. Having verified the algorithm with simulation experiments, we plan to use it to conduct 4D phase space tomography in the MEBT and HEBT of the heavy ion linac CAFe II.

        Speaker: Liwen Liu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Neural network technique for improving accuracy, reliability and robustness of beam position monitor system 1h 30m

        The beam position monitor (BPM) is a crucial instrumentation system for the commissioning and operation of the accelerator. Its accuracy and robustness are essential for ensuring the stability of the accelerator. Currently, the beam position is calculated by fitting a polynomial to the four voltage signals obtained from the BPM electrodes in BEPCII and HEPS. To improve the system’s robustness, a formula is
        provided that expresses the relationship between the three voltage signals and the position. The average fitting error is 40 𝜇m, but the error of the three-electrode calculation is not high. Therefore, we propose using neural networks for beam position calculation to improve the system’s robustness while guaranteeing its accuracy. This will ensure that the beam position can be provided stably, even in the case of one single electrode error. In our experiments, we use BPM calibration data from HEPS. The trained neural network’s performance on the test set meets the accuracy requirements,
        with an error of less than 15 𝜇m in both four-electrode and three-electrode predictions, and an average value of fitting error is 1 𝜇m. Furthermore, we validate the neural network’s generalization ability by using data measured by BPM on HEPS.

        Speaker: Fangqi Huang (Institute of High Energy Physics)
      • 16:00
        Neutron detection system of the NDPS at RAON 1h 30m

        The Nuclear Data Production System (NDPS) was constructed at Rare Isotope Accelerator complex for ON-line experiments (RAON) to produce nuclear data for neutron-induced reactions at a few tens of MeV. For the neutron time-of-flight measurement, various neutron detectors, such as gas-filled Parallel Plate Avalanche Counter (PPAC), MICRO-MEsh-GASeous (MICROMEGAS), and EJ-301 liquid scintillation detectors, were installed in the NDPS neutron beamline.
        The NDPS recently performed its first beam commissioning with 16 MeV/nucleon 40Ar ion beams. For the measurement of the neutron beam, EJ-301 liquid scintillation detectors and activation foils (natAl, natFe, natZr, natAu, natBi, etc) were used to measure the neutrons from the graphite target. In this presentation, we report a detailed description of the NDPS neutron detection system with its current status.

        Speaker: Cheolmin Ham (Institute for Basic Science)
      • 16:00
        New interferometric aperture masking technique for full transverse beam characterization 1h 30m

        The classical double-aperture interferometry using the visible part of the synchrotron radiation has been used in accelerators for beamsize measurements since the late 90s. However, this technique provides the beam size projection only in the direction given by the two aperture centers (i.e. only the horizontal or vertical direction). To fully characterize the transverse electron beam ellipse, given by the two semi-axis of the ellipse and its tilt angle, the double-aperture system could be rotated in a process that can take few minutes. Instead, using radio-astronomy techniques, this paper shows a new interferometric method with several apertures by which a full 2d transverse beam characterization is done in real-time.

        Speaker: Ubaldo Iriso (ALBA-CELLS Synchrotron)
      • 16:00
        Offline Calibration and Error Correction of the Stripline BPM for the HALF Injector 1h 30m

        This study conducted offline calibration tests on the stripline Beam Position Monitor (BPM) designed for the Hefei Advanced Light Facility (HALF) injector. The Lambertson method was used to measure the off-set between the electrical center and the mechanical center of the BPM, with results showing horizontal and vertical offsets of 0.1154 mm and 0.1661 mm, respec-tively. Additionally, the wire-scan method was em-ployed to construct the BPM mapping, and polynomial fitting was applied to effectively reduce the BPM’s nonlinearity and system errors. The experimental re-sults provide essential data support for the optimiza-tion and practical application of the BPM in the HALF injector.

        Speaker: Dongyu Wang (University of Science and Technology of China)
      • 16:00
        On-line beam synchronous phase measurement using deep learning models 1h 30m

        The on-line calibration of beam synchronous phase (SP) is crucial for enhancing the operational efficiency of accelerators. Recently, we developed an artificial intelligence (AI)-based beam information measure model that uses transient beam loading information as input while simultaneously predicting beam current and SP. This method employs Long Short-Term Memory (LSTM) to extract multi-dimensional radio frequency (RF) time-series features and incorporates an attention mechanism to evaluate the weights of RF waveforms at different times. The method can work in complex operating conditions such as open-loop, closed-loop, and with or without cavity detuning, and has higher precision and stronger generalization capabilities compared to other online calibration method of SP (such as those based on cavity differential equations or RF beam vector). We validated the consistency of the algorithm results with BPM and BCM measurements on the Buncher of European Spallation Source. Our method achieves an mean absolute error of 0.28° for predicting SP and 0.47 mA for predicting beam current, showing very promising results.

        Speaker: Lijuan Yang (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Optimization of the kicker/BPM design with tapered striplines 1h 30m

        The injection kicker design exploiting strip-lines and linear taper connections of the strip-lines to the feedthroughs was proposed and has been successfully used in the DAFNE electron-positron collider [1]. Such a design has helped to reduce the device beam coupling impedance, to improve the uniformity of the deflecting electromagnetic fields and to provide better matching with the feedthroughs.
        In this paper we propose using nonlinear taper connections in order to decrease further the beam coupling impedance. We have performed numerical simulations and analytical studies of several nonlinear tapers demonstrating that the coupling impedance can be substantially reduced while keeping or even improving the transfer (signal) impedance of the strip-line kickers (or BPM).
        The effect of the nonlinear tapering is particularly important for short strip-line devices when the taper length is limited due to lack of available space and/or when the strip-lines are moved closer to the beam in order to increase the device shunt (signal) impedance.

        Speaker: Shalva Bilanishvili (Istituto Nazionale di Fisica Nucleare)
      • 16:00
        Preliminary Research and Development of BPM Electronics Upgrade for the RCS Ring in CSNS II 1h 30m

        The first phase of the China Spallation Neutron Source (CSNS) project aims to accelerate negative hydrogen ions to 80 MeV using a linear accelerator. Subsequently, these negative hydrogen ions are converted into protons after stripping, and then injected into a rapid cycling proton synchrotron. The proton beam is further accelerated to an energy of 1.6 GeV and guided through a beam transport line to a tungsten target, where spallation reactions gen-erate neutrons. With the initiation of the Phase II project of the China Spallation Neutron Source (CSNS II), the target power is anticipated to increase significantly to 500 kW in the future. Upgrading the existing 32 sets of BPM electronics on the Rapid Cycling Synchrotron (RCS) ring is essential to accommodate the enhanced beam power and fulfill the new requirements of the beam measurement. This paper focuses on the novel design and validation of the BPM electronics, as well as the execu-tion of tests during beam operation.

        Speaker: Ruiyang Qiu (Institute of High Energy Physics)
      • 16:00
        Progress of low-β BPM calibration based on helical slow-wave structure 1h 30m

        Beam Position Monitors (BPMs) are essential in parti-cle accelerators for the precise measurement of beam trajectories. Considering the inherent inaccuracies in manufacturing and assembly, rigorous offline calibration processes are essential to guarantee the precision of beam position measurements. The predominant calibration technique, specifically the wire test method, is tailored for relativistic beams and is inappropriate for low-β beams. This manuscript introduces an innovative ap-proach employing a helical slow-wave structure to emu-late the electromagnetic fields of low-energy beams, thus facilitating the calibration of BPMs for low-β scenarios. Employing a helix-based calibration platform, we con-ducted the calibration of the nonlinear response of BPMs at the Xi'an Proton Application Facility for a 7 MeV pro-ton beam, with results aligning with the simulation. This advancement expands the precision and range of beam position measurements, substantially enhancing the op-eration and optimization of particle accelerators.

        Speaker: Minwen Wang (Northwest Institute of Nuclear Technology)
      • 16:00
        Prototype of BPM electronics for FEL-HMF 1h 30m

        This paper presents a prototype of BPM electronics for experimental installation of free electron laser and high magnetic field (FEL-HMF). FEL-HMF integrates mid-long Infrared free electron laser, high magnetic field and cryogenic, which is a critical apparatus for new advanced materials especially for low-power electronic materials. The BPM electronics consists of two ADC chips and one FPGA SoC. The ADC has two channels, and sampling rate is 240Msps. The FPGA SoC implements high speed digital signal and data process. The logic part of FPGA SoC is running signal process. The processor part of FPGA SoC runs Linux operating system and EPICS-based user application program. This BPM electrons has been tested and analyzed in lab. Its X and Y position is ~1.4um (RMS).

        Speaker: Wei Peng (Anhui University)
      • 16:00
        Research on X-ray beam position front-end electronics based on diamond detectors 1h 30m

        This project aims to collect high-frequency high-precision data from the weak current signals generated by the quadrant-type diamond detector used for high-precision beam position monitoring. The main approach is to design a current conversion amplification circuit based on the theory of high-resistance I-V weak current to achieve fast conversion and collection of the four-channel weak current with large dynamic range and multiple ranges at high frequency, with the highest precision reaching the pA level. The circuit uses the ADA4530-1 amplifier with extremely low input bias current budget to complete the front-end circuit setup. The circuit's bandwidth is simulated and analyzed, with the bandwidth limited to 159 Hz. The design uses a protection ring design, a three-axis BNC connection, and a custom shielded box to enhance the shielding performance of the measurement system. The output signal is converted to a 24-bit high-precision analog-to-digital signal by the AD7172-2, and further connected to the core control board for signal closed-loop control to achieve overall isolation of the analog and digital circuits. The final experimental test shows that the detection sensitivity of the circuit for pA-level weak currents is 9.7936 mV/pA, and the error of the circuit is 1.3% when the weak current is greater than 10 pA, which can meet the demand for beam position measurement in the stable beam system.

        Speaker: Kai Wang (Institute of High Energy Physics, Chinese Academy of Sciences)
      • 16:00
        SOLEIL II BPM: design, simulations and button prototyping. 1h 30m

        SOLEIL II is the low emittance upgrade project for Synchrotron SOLEIL, targeting an emittance of ~80 pm.rad. The new lattice includes 180 Beam Position Monitors (BPM). Due to the different constraints on the magnet yokes, beam stay clear and synchrotron radiation, 3 different types of BPM will be installed on the storage ring with inner diameter distributed between 16 and 24 mm. Electromagnetic and thermal simulations have been conducted to validate the designs.
        Manufacturing the feedthroughs is a challenge due to the conical shape of the button and the small (200 µm) thickness of the gap with the BPM body. Prototypes of the button have been made by two different manufacturers, and possibilities for improvement identified. These prototypes will test in the current machine to validate the simulation results.
        This paper presents the designs, summarizes the results of the simulations, and describes the metrology process and results of the two batches of feedthroughs.

        Speaker: Moussa El Ajjouri (Synchrotron Soleil)
      • 16:00
        Stripline design for tune measurement in the ILSF Storage Ring 1h 30m

        The Iranian Light Source Facility Storage Ring is under design with a 528 m circumference and will store the electron bunches with 3 GeV energy to produce high-flux radiation that ranges from infrared to hard X-rays. Two Striplines are planned to be installed in the ILSF storage ring for beam tune measurement. The first one will be used for exciting the beam and the other for horizontal and vertical beam position measurements. In this paper, the design of the striplines for the ILSF storage ring is investigated. Each stripline is matched with 50Ω and has 4 strips (electrodes) that are placed at 45 degrees to the beam axis, the best geometry is achieved and optimized by CST Microwave Studio simulation.

        Speaker: Samira Mohammadi Alamouti (Iranian Light Source Facility)
      • 16:00
        Study and FPGA implementation of BPM algorithm for synchronized light source 1h 30m

        Beam Position Monitor (BPM) system is an important part of the beam measurement system, which plays a vital role in the stable operation of the accelerator. In this paper, based on the requirement of high resolution of the BPM system, the DBPM algorithm is implemented on Matlab and FPGA, firstly, the overall design of the DBPM algorithm is introduced; secondly, the implementation method of each module is elaborated in detail; and again, the existing simulation data and the beam current data are simulated in the Matlab and Modelsim environments respectively, using the quadrature demodulation and Moving Average Filter; finally,do offline testing based on this DBPM algorithm Experimental. Results show that the quadrature demodulation algorithm incorporating a sliding average filter has higher positional resolution.

        Speaker: Zhenan Liu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Study of X-ray Fresnel Diffractometry for Small Beam Sizes at Diamond Light Source 1h 30m

        The feasibility of X-ray Fresnel diffractometry to measure small beam sizes beyond the resolution of X-ray pinhole cameras is studied for the case of Diamond Light Source. After the Diamond-II upgrade, beam sizes as small as 4 µm are anticipated and are not resolvable by the X-ray pinhole cameras, which are the workhorse for beam size, emittance, and energy spread measurements. X-ray Fresnel diffractometry employs a single slit with an optimised width, producing a double lobe diffraction pattern. The visibility of this double lobe intensity distribution relates to the beam size and promises micron-scale beam size measurement. Numerical studies and simulations have been conducted to assess the feasibility of diffractometry for Diamond Light Source. The parameters for the experimental setup have been determined and preliminary experimental results are presented. Challenges and improvements for achieving this measurement for Diamond-II are discussed.

        Speaker: Niki Vitoratou (Diamond Light Source Ltd)
      • 16:00
        Test of BPM cables vs temperature and humidity 1h 30m

        Measuring the absolute position of the beam in the intensifier and storage ring of a high energy photon source (HEPS) requires measuring the offset between the electrical and mechanical centers of the beam position monitor (BPM). In the HEPS project, a four-electrode BPM is used, and the signals from each of the four electrodes of the BPM probe are led out by a cable. During the operation of the intensifier and storage ring, the influence of ambient temperature and humidity on the BPM cable and the difference between the four channels will directly lead to changes in the BPM measurement results. In this paper, vector network analyzer (VNA) is used to test the data of signal amplitude change of two BPM cables within ten hours when temperature and humidity change. The conclusion is that the influence of temperature on the signal is about 0.01 dB/℃, the influence of humidity on the signal is about 0.05 dB/10%, and the relative change between channels is about 5%.

        Speaker: Chongyang Liang (Chinese Academy of Sciences)
      • 16:00
        The beam diagnostics of 300MeV proton and heavy ion synchrotron for SESRI project 1h 30m

        The SESRI (Space Environment Simulation and Research Infrastructure) is a large-scale space science and technology experimental research accelerator clusters, the 300MeV proton and heavy ion accelerator is the key part. It consists of an ECRIS (Electron Cyclotron Resonance Ion Source), a linac cascade injector, a compact synchrotron, and three irradiation terminals. The proton and HI with 2MeV and 5.6MeV/U can be injected, and slowy extracted from the ring with the RF-KO and Ese. The operation cycle is about 3-10s. The Scintillation Screens are used to monitor the beam profile. They are driven by motors for the different orbits. The wire scanners are used to measure the beam profile during the acceleration process, in order to obtain the beam emittance; In order to meet the requirements of large current range, the BPM system adopts a Libra adjustable gain amplifier, and uses Libra Hadron to achieve BBB and 1kHz closed orbit measurement. RF-KO provides a transverse extraction electric field.Amplitude and frrequency modulation are used for the extraction signals. At the same time, a feedback system based on excitation and fast quadrupole is adopted. Through the above methods, the uniformity of beam extraction is greatly improved.

        Speaker: Tiecheng Zhao (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        The design and accurate calibration of HIAF-Ring BPM 1h 30m

        Beam Position Monitors (BPM) are the non-destructive monitors used most frequently at nearly all linacs, cyclotrons, and synchrotrons. The most basic function of BPM is to provide the accurate position of the centre of mass of the beam for closed orbit feedback and other demands. However, due to the error of actual processing, the k value and the actual electric center will be different with the ideal k value and electric center of BPM, which requires us to accurately measure the k value and offset value of each set of BPM offline.
        There are 72 sets of BPMs in HIAF BRing & SRing, with 10 specifications and plate radius ranging from 180mm to 330mm, but the shape and size of the front and back pipes connected to bpms are variety during actual installation. Based on theoretical analysis, the k value and offset value of the BPM which electrode plates are too close to the flange are greatly affected by the pipes connected to bpm at both ends, and the measurement error can even reach 9mm. Therefore, this paper takes HIAF BRing and SRing BPM calibration as examples to explain how to accurately calibrate BPM.

        Speaker: Peilin He (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        The design of beam instrumentation system of SILF 1h 30m

        Shenzhen Innovation Light-source Facility (SILF) is designed to be the so-called forth generation synchrotron radiation light source operating at 3.0 GeV, 300 mA, and with the emittance less than 100 pm∙rad. With the increase in luminosity of the light, higher stability of the electron beam is required, which may also result in increased measurement diversity and accuracy. Here, an overview of the SILF beam instrumentation system is provided, along with detailed descriptions of its key technology, including the Beam Position Monitor (BPM) and electronics, transverse feedback kicker and electronics, and beam transverse size measurement. Additionally, the future development of the beam instrumentation system is discussed.

        Speaker: Tao Yu (Institute of Advanced Science Facilities)
      • 16:00
        The development of new BPM signal processor at SSRF 1h 30m

        A BPM signal processor has been developed for SSRF since 2009. It composed of Virtex5 FPGA, ARM board, and 4 125MSPS sampling rate ADCs. Since then, electronic technology has made significant progress. Such as Zynq UltraScale+ MPSoC FPGA contains both hard-core ARM and high-performance FPGA, and ADCs with a sampling rate of 1GSPS have been applied in mass production. A new BPM processor with Zynq UltraScale+ MPSoC FPGA and 1GSPS ADCs is under development at SSRF. Due to the application of new technologies, the processor performance will be significantly improved. The new processor can also meet the needs of ultra-low emittance measurement for the new generation of light sources. This paper will introduce the design of the processor and the relative tests.

        Speaker: Mingjie Zhang (Shanghai Institute of Applied Physics)
      • 16:00
        Wire scanner based beam diagnostics during energy-recovery operation at the S-DALINAC 1h 30m

        The electron accelerator S-DALINAC can be operated in conventional acceleration (CA) and energy recovery (ER) modes. In an ER mode, electrons pass the main linear accelerator (LINAC) twice as often compared to the corresponding CA mode: following the acceleration, the electrons are decelerated to return kinetic energy to the electromagnetic fields inside the cavities of the main LINAC. The recovered energy is recycled during the acceleration of subsequent electrons. However, as a result of the deceleration, the electromagnetic fields are impacted. Thus, the fields and consequently the beam properties after acceleration in ER mode differ from those in CA mode. To compare the beam properties after acceleration present in both modes, a non-destructive diagnostic system is necessary since otherwise the ER mode would be interrupted. For this reason, wire scanners were build and used to measure beam properties in the two-turn CA and the two-turn ER mode. Details on the wire scanners and the measurements are presented.

        Speaker: Felix Schliessmann (Technische Universitaet Darmstadt)
    • 09:00 10:00
      WEA: Data Acquisition and Processing Platforms: WEAI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Yongbin Leng (University of Science and Technology of China)
      • 09:00
        FWK - an open-source FPGA framework by DESY for large scientific projects 30m

        In recent years, DESY has dedicated significant effort to the development of an open-source FPGA framework named FWK. This initiative is geared towards expediting FPGA development within the scientific community, with a particular focus on experimental physics applications. The framework functions as an abstraction layer, streamlining the utilization of diverse FPGA vendor tools, facilitating IP integration, simplifying register and documentation creation, and offering a host of additional advantages. In conjunction with FWK, DESY is committed to providing numerous IPs as open-source resources that seamlessly integrate with the framework. This presentation is intended to provide a comprehensive overview of the framework, accompanied by concrete examples drawn from real-world applications.

        Speaker: Michael Büchler (Deutsches Elektronen-Synchrotron)
      • 09:30
        Remote sensing of fast beam signals using electro-optical modulators 30m

        Electrical measurements of fast signals, as generated in particle accelerators, encounter severe limitations due to the high-frequency losses in RF transmission lines. This study describes measurements conducted with electro-optical modulators employing various radio-over-fibre techniques. Experimental data consist of different beam-generated signals, which underline the versatility of such a system. Signals from electromagnetic devices such as wall current monitors, as well as those captured from coherent transition radiation screens and coherent Cherenkov diffraction radiators, are presented. The potential deployment of such a remote sensing acquisition system in large-scale facilities is discussed.

        Speaker: Andreas Schloegelhofer (European Organization for Nuclear Research)
    • 10:00 10:20
      WEA: Data Acquisition and Processing Platforms: WEAC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Yongbin Leng (University of Science and Technology of China)
      • 10:00
        Newly developed digital signal acquisition and processing platform for beam instruments at IMP 20m

        A new digital signal acquisition and processing platform for beam instruments at IMP is designed and realized based on Zynq MPSoC FPGA. Two FMC mezzanine slots are featured for analogue front-end electronics and analogue-to-digital converting, as well as for the WR timing. The real-time data communication between different platforms is realized through multi-gigabit links. To facilitate the real-time data transmission from PL to PS, an universal technology for high-speed, multi-channel data transmission is developed, where two channels can achieve a transmission rate of up to 2 GB/s in a 64-bit data stream with a maximum clock of 250 MHz per channel, and the other two can achieve a data-throughput of 1.28 GB/s in a 512-bit width with a maximum clock of 20 MHz individually. This technology has been verified by the synchrotron BPMs for simultaneous transmission of the raw data with a sampling rate of 250 Msps from each electrode, the turn-by-turn trajectory data, as well as the orbit data without any conflict. Additionally the trajectory data are processed on an Arm Cortex-R5F real-time processor integrated on the MPSoC to get a real-time tune measurement. Till now the platform is implemented and operated at IMP machines for all beam instruments such as beam current, BPMs, beam loss measurement and so on. From on-line operation, the platform have an excellent performance and good long-term stability. Also the platform is utilized for the HIAF machine protection system.

        Speaker: ZhiXue Li (Institute of Modern Physics, Chinese Academy of Sciences)
    • 10:20 10:50
      Morning Coffee Break 30m
    • 10:50 11:50
      WEB: Transverse Profile and Emittance Monitors: WEBI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Fernando Cardoso (Brazilian Synchrotron Light Laboratory)
      • 10:50
        Achieve a record dynamic range of halo diagnostics with a novel fluorescence wire scanner 30m

        Achieving sustainable beam operation in high-power accelerators requires careful control and minimization of halo-particle-induced beam loss. To accomplish this, it is important to have a clear understanding of the halo-particle distribution. While state-of-the-art instruments can achieve a dynamic range of ~10^6 with counting readout schemes, a novel fluorescence wire scanner combined with a conventional metal wire has recently been proposed and demonstrated at CSNS. This new approach has achieved a sensitivity at the single-particle level and a dynamic range of over 10^8. A 100x1x0.15 mm^3 Chromox fluorescence wire has been prepared at CSNS, which has demonstrated excellent light yield and radiation hardness. By capturing fluorescence images with a CMOS camera in a dark environment, a new record dynamic range of about 6x10^8 has been achieved. Continue efforts on optimizing the fluorescence wire, observation system, and sensor hold promise for further improvements in dynamic range and sensitivity.

        Speaker: Renjun Yang (Institute of High Energy Physics)
      • 11:20
        Development of high-resolution single-shot emittance diagnostics 30m

        A pepper-pot diagnostic device was developed to accurately and robustly retrieve particle distribution in horizontal and vertical phase spaces by single-shot emittance measurements. Two masks that differ in both composition and manufacturing method were fabricated: one made of phosphor bronze by an optical lithography process and another made of stainless steel (SUS) by laser cutting. Scanning electron microscope (SEM) measurements of the two masks revealed that the former is superior in terms of regularity and shape
        of the mask holes and is therefore more suitable to use. A new image-processing algorithm, cluster noise removal method, was developed which improves the resolution of the phase-space distribution measurements over traditional methods. The results show that the diagnostics can robustly and reliably retrieve the four-dimensional (4-D) phase-space distribution of ion beams with a single-shot measurement.

        Speaker: Ji-Gwang Hwang (Gangneung-Wonju National University)
    • 11:50 12:30
      WEB: Transverse Profile and Emittance Monitors: WEBC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Fernando Cardoso (Brazilian Synchrotron Light Laboratory)
      • 11:50
        First proof-of-concept transverse beam profile measurements with gas jet in-vivo dose profiler for medical accelerators 20m

        To ensure patient safety, treatment efficacy, and facility efficiency, a full online characterisation of the charged particle beam is required for every ion beam therapy facility. Current dosimetry methods offer limited information or are invasive to the beam, asking for the development of in-vivo dosimetry solutions.
        The QUASAR Group, based at Cockcroft Institute in the UK, has been developing non-invasive beam monitor for medical accelerators since 2015. Detailed transverse beam profile monitoring is the first step towards in-vivo dosimetry. The current monitor applies a supersonic beam gas curtain, interacting with a charged particle beam to then exploit the resulting impact ionization to record the transverse beam profile. A prototype monitor was tested at Dalton Cumbrian Facility’s pelletron accelerator for proof-of-concept beam measurements in summer 2023. The measurements were carried out for different beam energies, sizes and intensities and with both, proton and carbon ion beams. This contribution presents the monitor design and functioning principle, results from the experimental campaign, and planned upgrades to achieve real-time, non-invasive dosimetry.

        Speaker: Dr Narender Kumar (Cockcroft Institute)
      • 12:10
        Evaluating the use of common statistical divergences to quantify the differences between beam distributions in high-dimensional phase space 20m

        Quantifying the difference between two beam distributions in high-dimensional phase space is crucial for interpreting experimental or simulation results. This study aims to analyze and compare several common statistical divergences that quantify the differences in high-dimensional distributions, and to determine which of them are suitable for beam physics applications. We tested these divergences with common kinds of initial distributions by computing how the difference values vary when the mismatch factor and emittance change, between the same and different kinds of distributions. These results, along with similar comparisons after extended beam transport, provided guidance on the use and choice of statistical divergences for beam phase space distributions.

        Speaker: Yu Du (Institute of Modern Physics, Chinese Academy of Sciences)
    • 12:30 13:30
      Lunch Break 1h
    • 13:30 14:00
      WEC: Feedback Systems and Beam Stability: WECI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Lorraine Bobb (Diamond Light Source Ltd)
      • 13:30
        Bunch by bunch feedback systems review 30m

        Bunch-by-bunch feedback systems have become essential components of high-energy particle accelerators, particularly for ultra-low emittance rings. These systems have been widely used in accelerator facilities to ensure beam quality and to apply them to extensions such as beam diagnostics or manipulation. Bunch-by-bunch feedback systems include various hardware components and related technologies, ranging from fast digital signal processing to high power radiofrequency devices.
        This talk would be an overview of the bunch by bunch feedback systems and present the outcome and conclusions of the iFAST Workshop hosted by KIT in March 2024.

        Speaker: Takeshi Nakamura (High Energy Accelerator Research Organization)
    • 14:00 14:20
      WEC: Feedback Systems and Beam Stability: WECC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Lorraine Bobb (Diamond Light Source Ltd)
      • 14:00
        Modeling of the SIRIUS fast orbit feedback control loop 20m

        The SIRIUS Fast Orbit Feedback system was put into routine operation for users in 2022. New system identification experiments were conducted to develop an accurate black box MIMO model of the feedback loop. The high frequency response discrepancies among several fast corrector magnets are captured in this model and allow prediction of closed loop behavior, which is especially important for designing high gain controllers. This paper describes the obtained model, its validity and enabled improvements on the feedback loop performance and robustness.

        Speaker: Lucas Antonio Pelike (Brazilian Synchrotron Light Laboratory)
    • 14:20 14:50
      Afternoon Coffee Break 30m
    • 14:20 15:50
      WEP: Wednesday Poster Session: WEP China Hall 3

      China Hall 3

      • 14:20
        A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL 1h 30m

        The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler.
        For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important.
        New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.
        We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

        Speaker: Yoshinori Hashimoto (High Energy Accelerator Research Organization)
      • 14:20
        A generic and efficient aggregation method within neutron spectrometer data process framework based on the synchronous trigger and tagging system 1h 30m

        In the recent project of China Spallation Neutron Source (CSNS), a new designed distributed stream-processing framework is applied as the fundamental schema of data process system on user cooperative instruments. It is constructed with the open-source Apache Kafka software, which aims to aggregate the big data for manipulation sharing, and also with a synchronous trigger and tagging system, which provide synchronous ID for data correlation among different target hitting cycles. Correlated data could be identified among different measurements for aggregative analysis in a high efficient way, which greatly improve the performance of data processing.In concert with the real-time capability on stream-processing platform, WYSIWYG characteristics is achieved either. Performance and adaptability of this technique has been validated during the operation of constructed user cooperative instruments in CSNS. An increasing number of data-processing functions and experiment methods have got benefit from it.

      • 14:20
        Accurate Beam Spot Fitting Algorithm Using Generalized and Skewed Gaussian Type Distributions 1h 30m

        To address non-standard Gaussian beam spot pro-files in injectors, this paper proposes a fitting algo-rithm based on Gaussian, the newly introduced Gener-alized Gaussian Type and Skewed Gaussian Type dis-tributions. These distributions are specifically de-signed to better fit non-Gaussian and asymmetric beam spots by automatically selecting the most suitable model. Validation using beam spot images from the YAG screen after the electron gun in the Hefei Light Source II (HLS-II) injector demonstrates that the Gen-eralized Gaussian Type is effective for fitting sharp or broad profiles, while the Skewed Gaussian Type is well-suited for handling asymmetry. Compared to tra-ditional methods, the proposed algorithm improves fitting accuracy and adaptability, providing a practical solution for complex beam measurement challenges.

        Speaker: Dongyu Wang (University of Science and Technology of China)
      • 14:20
        An online 2D spatial-resolved proton spectrometer based on a scintillation-fiber-cube 1h 30m

        The applications of proton beams require precise diagnosis of their properties including spectrum and spatial distribution. Distinct from the case of traditional accelerators, limited online detectors are available for laser-driven proton beams with high transient fluence, somewhat impeding the progress in this field.

        This paper presents an online proton spectrometer, named Scintillation Fiber Cube Proton Spectrometer (SFCPS), which can diagnose proton beams with sub-millimeter (~500 um) spatial resolution and wide fluence range. The SFCPS offers an energy range of approximately 6~93 MeV with an energy resolution of 0.5% at 80 MeV, as calibrated. We demonstrated the SFCPS's ability to reconstruct the 2D energy spectrum of parallel proton beams with uneven spatial distributions. Further discussion and analysis reveal that the SFCPS's lower detection threshold for proton beams is approximately 1×10^5 p/cm2.

        Speaker: Tan Song (Peking University)
      • 14:20
        An X-ray pinhole camera for SESAME Storage Ring 1h 30m

        An X-Ray pinhole camera beamline has been installed recently at SESAME storage ring as a very beneficial non-destructive tool, used to characterize the electron beam size and behaviour. The design of the beamline is kept as simple as possible with a modification on the copper absorber to provide a sufficient flux of X-ray proper for imaging. The beamline is under operation now and used for the measurement of beam size, emittance, coupling in the ring, and detection of beam instabilities. This paper describes the design details, simulations and measurement results obtained during the beamline com-missioning.

        Speaker: Hussein Al-Mohammad (Synchrotron-light for Experimental Science and Applications in the Middle East)
      • 14:20
        Application of open source hardware in the beam loss monitor system 1h 30m

        The Beam Loss Monitoring system (BLM) for the HEPS booster ring consists of 27 plastic scintillators and 4 optical fibers. An open source hardware is used in the data acquisition of the Scintillator BLM system, to monitor the beam loss during the injection and energy ramping process. Design details and application is described in this paper and the commissioning results of is also present.

        Speaker: Ying Zhao (Institute of High Energy Physics)
      • 14:20
        Application of reinforcement learning for efficient beam tuning in CiADS room temperature front-end prototype accelerator 1h 30m

        In proton accelerators, nonlinear effects, such as space charge effects and fringe field effects, significantly contribute to the nonlinear characteristics of beam dynamics and control strategies. These nonlinear characteristics increase the degree of coupling between accelerator control elements, complicating the beam commissioning process and extending beam tuning time.
        Reinforcement Learning (RL) is adept at swiftly formulating decisions contingent upon the prevailing system state and control demands, thereby offering an efficacious control strategy for accelerator systems. We have conducted a study on beam tuning based on reinforcement learning for application in the beam tuning process of the current CiADS room temperature front-end prototype accelerator. The goal of this research is to enhance the efficiency of the tuning process. To achieve this, we trained RL agents in a simulated environment. Subsequently, the successfully trained agents will be tested in the real accelerator environment to validate their effectiveness.

        Speaker: Yu Du (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Beam diagnostic beamlines at HEPS storage ring 1h 30m

        High Energy Photon Source (HEPS) is a 6 GeV dif-fraction limited storage ring light source. An ultralow emittance of ~34 pm·rad is designed with a multiple-bend achromat lattice at storage ring. The transverse beam sizes at the dipoles will be less than 10 µm. In order to measure such small beam sizes in both directions, an X-ray beam diagnostic beamline is designed with bend-ing magnet as source point. X-ray pinhole imaging and KB mirror imaging are used compatibly and comparably to capture beam image. A visible light beam diagnostic beamline is designed to measure bunch length with streak camera. During the first phase storage ring commissioning time, both diagnostic beamlines captured the first light.

        Speaker: Dr Dechong Zhu (Institute of High Energy Physics)
      • 14:20
        Beam diagnostics control system upgrade of IPM LINAC 1h 30m

        A series of upgrades has now begun to industrialize the applications of the experimental IPM electron LINAC. This includes upgrading the control system of the diagnostics tools and adding new tools and equipment to the system as well.
        The aim is to build an integrated control system to collect and manage all diagnostics signals. This will allow us to continuously monitor and archive all of the beam parameters for LINAC performance analysis and improvement. It is hence decided to migrate from LabVIEW to an EPICS-based control system which has many advantages in this regard. In the meantime, it is also required to employ more modern equipment with better control interfaces and add some extra diagnostics tools to the system as well. So during this upgrade, most of the job would be developing new control interfaces and high-level applications accordingly.
        In this paper, after a brief summary of the current diagnostics tools and our motivation for this upgrade, the scheme of the new control system and how different parts are integrated to the EPICS framework will be described.

        Speaker: Samira Mohammadi Alamouti (Iranian Light Source Facility)
      • 14:20
        Beam profile monitoring using incoherent Cherenkov Diffraction Radiation and scintillating screens at ILSF 1h 30m

        The Iranian Light Source Facility (ILSF) plays a crucial role in advancing accelerator science and applications. In this study, we explore innovative techniques for precise beam profile monitoring, focusing on two complementary methods: Incoherent Cherenkov Diffraction Radiation (ChDR) and scintillating screens. Incoherent ChDR occurs when a charged particle passes through a dielectric medium with a velocity exceeding the phase velocity of light in that medium. This phenomenon leads to the emission of electromagnetic radiation in the form of a cone. Our investigation focuses on incoherent ChDR as a powerful tool for beam position diagnostics. By analyzing the angular distribution of ChDR photons, we extract valuable information about the transverse position of the electron bunch. Our simulations demonstrate the feasibility of ChDR-based diagnostics at ILSF. We discuss optimal radiator materials, geometries, and detection strategies.
        in addition, We also present our findings on scintillating screen calibration, spatial resolution, and dynamic range.
        We believe that our research significantly contributes to the development of robust and efficient beam diagnostics at the storage ring of ILSF. By investigating Cherenkov Diffraction Radiation (ChDR) and utilizing radiation from scintillating screens, we enhance accelerator performance and facilitate future experiments.

        Speaker: Samira Mohammadi Alamouti (Iranian Light Source Facility)
      • 14:20
        Bunch resolved transverse beam diagnostics at BESSY II 1h 30m

        For diagnostics of the different bunch types at the BESSY II electron-storage ring, a streak camera and a fast-gated ICCD camera have been installed at two neighbouring beamlines, both of which are powered by visible light from the same dipole magnet. This contribution is focused on the ICCD camera and its first applications. After an improvement regarding the ICCD repetition rate, the maximum illumination rate exceeds now the BESSY II revolution frequency of 1.25 MHz. Furthermore, we have improved the optical light-transfer system and characterized the optical magnification, the spatial resolution and time resolution of the system.
        Initial measurements have been restricted to direct bunch-resolved imaging of the 2-dimensional transverse shapes of different types of bunches. Specifically, the Pulse Picking by Resonant Excitation (PPRE*
        ) bunch is investigated in more detail. This bunch is horizontally broadened by a quasi-resonant incoherent perturbation *** and leads to pseudo single-bunch radiation within the complex multi-bunch fill-pattern at the BESSY II storage ring.

        Speaker: Irma Shmidt (Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH)
      • 14:20
        Bunch-by-bunch profile measurement during beam available time 1h 30m

        This paper presents a bunch-by-bunch profile measurement system, which includes an optical imaging frontend, a multi-channel photomultiplier tube (MAPMT) for photoelectric conversion, and a high-sampling-rate oscilloscope for data recording. The system is capable of measuring the transverse positions and sizes of each bunch in the storage ring during the beam availability period of the Hefei Light Source II (HLS-II). By finely processing the collected data, the system can effectively recognize the dynamic characteristics of the beams and monitor the performance of the light source. Here, the paper elaborates on the system’s design principles, optical layout and system configuration. It also introduces the program workflow of data processing, along with an analysis of the corresponding measurement errors.

        Speaker: Ruizhe Wu (University of Science and Technology of China)
      • 14:20
        Compact semiconductor sensor for monitoring of energy distribution in heavy ion beams 1h 30m

        During experiments in particle accelerators online monitoring of energy distribution in particle beam is useful for correction of the accelerator setting and parameters. Time of flight (ToF) technique for energy monitoring is well known and approved method, which is used widely. Nevertheless ToF technique requires long flight bases especially for high energy particles and can’t be used to estimate spatial heterogeneity of the particle beam. Semiconductor energy sensors are compact and can be successfully used for these applications. Diodes with p-i-n structure are used for energy monitoring of particles with rages less than thinness of sensitive volume. High energy particles have long ranges in semiconductor materials. For online monitoring of high energy beams in this work we propose and experimentally verified a technique based on determination of linear energy transfer (LET) values of particles using diode structures with p-n junctions. Experimentally obtained LET value enables us to calculate energy if the particle type and diode semiconductor material are known. Proposed technique was successfully experimentally verified.

        Speaker: Alexander Bakerenkov (Branch of JSC URSC - ISDE)
      • 14:20
        Data Acquisition And Processing Platform Design For SHINE Wire Scanner 1h 30m

        The Shanghai High repetition rate XFEL and Extreme light facility (SHINE) accelerates electrons to 8GeV with a high repetition rate of up to 1MHz. For the transverse beam profile measurement in the high energy sections wire scanner is used as an essential part of the accelerator diagnostic system, providing the tool to measure small beam size in an almost non-destructive manner. The prototype of the data acquisition and processing platform of wire scanner is designed and installed at the Shanghai soft X-ray Free Electron Laser (SXFEL) for verification. The experimental results show that the platform can be used for the SHINE.

        Speaker: Mr Jian Dong (Shanghai Synchrotron Radiation Facility)
      • 14:20
        Deep learning framework for fault detection in accelerators 1h 30m

        The main goal of NSRC SOLARIS is to provide the scientific community with high-quality synchrotron light. To achieve this, it is necessary to constantly monitor many subsystems responsible for beam stability and to analyze data about the beam itself from various diagnostic beamlines. This work presents an in-depth analysis of multi-modal, deep learning-based frameworks for fault detection within big research infrastructures, with a specific focus on accelerator facilities. The study explores diverse approaches and architectures for identifying anomalies indicating potential faults in operation. At the present stage, a binary classification is performed: stable beam operation or unstable beam operation / no beam with the accuracy of 90%. The models and the results obtained so far are discussed, along with plans for future development.

        Speaker: Michal Piekarski (National Synchrotron Radiation Centre)
      • 14:20
        Design and development of embedded EPICS system for beam measurement electronics 1h 30m

        The embedded EPICS control system for beam measurement is implemented based on the Zynq 7z020 SoC, which enables efficient and reliable real-time data acquisition, transmission, processing, and PV publishing of embedded IOCs. The data acquisition module uses a 24-bit ADC with a sampling frequency of 10Msps, which enables continuous sampling and data processing of detector signals, and interlocking signals can be output within 10μs. Data transmission and communication from the PL to the PS is achieved through the AXI bus, and the real-time data of different BRAMs and registers is accessed by manipulating memory base addresses and offsets. The ADC raw data with a continuous data rate of 200K/s can be stored without losing points. Through long-term online testing, the beam measurement electronics system can accurately monitor beam signals, output interlocking signals in a timely manner, and the software and hardware systems work stably and reliably for a long time. It can be widely used for signal measurement of beam loss, CT, Faraday cup, integral coil, power ripple, ionization chamber, wire scanner, etc.

        Speaker: Jianjun Su (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Design and implementation of mass spectrometer database 1h 30m

        Mass spectrometer, as a type of beam instrument, is capable of measuring and analyzing the mass and charge of different molecules and ions in a sample, thus identifying the type of particles. Mass spectrometer database software is an important part of mass spectrometer, which can realize the function of storing, managing, sharing and analyzing mass spectrometer data. Therefore, the establishment and improvement of specialized mass spectrometry databases and library retrieval techniques can facilitate the rapid identification and confirmation of compounds, providing a more efficient and accurate solution for substance detection. In this paper, a comprehensive mass spectrometry database management system is designed and implemented to simplify the user operation process from the collection, storage and management of mass spectrometry data to the querying, matching and analyzing of the data, providing a fast and accurate solution to meet the needs of scientific research on mass spectrometry data. The software uses Python for the implementation of core algorithms, builds a database based on MySQL and collects mass spectrometry data to fill in the database, and finally uses PyQt to design and implement a friendly and beautiful graphical user interface. With this software, unknown compounds in the samples can be identified and their possible structures and properties can be recognized, which provides a strong support for their application fields.

        Speaker: Lifan Liu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Design and inplementation of a high-precision time to digital converter based on ZYNQ 7000 1h 30m

        Time measurement technology is widely used in modern nuclear physics and partical physics experiments,aerospace and laser ranging etc.As its core technology,time to digital converter(TDC) is increasingly important.This paper presents a high-resolution TDC implemented in Xilinx ZYNQ 7000 device with a new encoder.This design introduces a novel pipeline-multiplexer encoder that realises 'bubble_proof' by using a coarse-fine counter method based on the FPGA carry chain.In comparision to the conventional Wallace tree encoder,the proposed design exhibits reduce hardware and area requirments,as well as a shorter critical path.Additionally,the propagation delay time per delay cell(bin width) is dependent on the temperature and power supply voltage of the hardware circuit,automatic calibration of the ARM is necessary to ensure optical performance.The resolution of differential nonlinearity(DNL) and integral nonlinearity(INL) is approximately 11ps.Gaussian fitting indicates that the precision of this system is within 50ps,which is in accordance with the desired design specification.

        Speaker: Jiaxu Hou (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Design and performance test of 8 channel 125 MS/s digitizer with 16-bit resolution for BPM and LLRF application 1h 30m

        In an accelerator, the Beam Position Monitor (BPM), which typically consists of beam position probe and electronics, plays a role of providing information on the position of the beam in the vacuum chamber at the monitor location. The low-level RF (LLRF) control system is mainly used to control the high-frequency field and resonant frequency of the accelerating cavity to ensure the stable operation of the accelerator and output high-quality particle beams. In order for particle gas pedals to deliver higher quality particle beam streams, high performance electronics are needed to match them. This paper introduces the development and testing of an 8-channel 16bit 12MSPS FMC card for BPM/LLRF applications. Test results show that this design is characterized by low noise and meets the requirements of BPM/LLRF applications.

        Speaker: Mr Qiutong Pan (Tsinghua University)
      • 14:20
        Design and test of an ionization profile monitor at the 80 MeV linac in CSNS 1h 30m

        The beam transverse profile is very essential in the beam diagnostics of a high intensity proton accelerator. A Residual Gas Ionization Profile Monitor (IPM) has been developed and implemented as a non-destructive diagnostic tool at the LRBT of CSNS. The design specifics of the IPM and presents initial measurements conducted in ion collecting mode are discussed in this paper. Big challenges arose during the initial experimental period, especially the honey comb. A series of planned experiments are outlined to address these challenges in future IPM developments.

        Speaker: Mengyu Liu (Chinese Academy of Sciences)
      • 14:20
        Design of AMC board accroding to MicroTCA.4 for BPM and LLRF application 1h 30m

        Beam position monitors are critical to ensuring that particle beams pass correctly through the various components of an accelerator, especially in high-precision experimental facilities such as colliders and synchrotron radiation sources. In recent years, in order to improve the performance and reliability of BPM systems, electronic systems based on MicroTCA have been widely developed and applied. MicroTCA is an advanced modular electronic platform that supports multiple AMC boards to operate on the same backplane and achieves a high degree of data integration and processing capabilities through high-speed backplane interconnection. In addition, the advanced management functions provided by the MicroTCA platform, such as power management, cooling control and module monitoring, further enhance system reliability and stability. The AMC board core chip developed in this study is based on Xilinx KU060 FPGA and has powerful data processing capabilities; the AMC connector supports Ethernet and 4-lane PCIe Gen3 links; it adopts the Zone3 adapter+dual FMC architecture, which can receive RTM transmission through Zone3 In addition to the signals. It can also directly use the FMC card to receive signals through the AMC front panel, supporting up to 16 channels of 125MHz ADC. In addition to core functions, this AMC board also has a data pre-processing function, which can perform preliminary processing and compression of data before sending it to the MCH.

        Speaker: Haoyan Yang (Tsinghua University)
      • 14:20
        Design of an S-band parallel-coupled transverse deflecting cavity with variable polarization for multi-dimensional phase space diagnostics in photoinjectors 1h 30m

        Beam quality from photoinjectors is crucial for lasing in Free Electron Laser (FEL) facilities. While phase space measurement are usually limited to 2D with conventional methods, the recently-developed transverse deflecting cavities (TDCs) with variable polarization provide the capability to measure multi-dimensional phase space information. Such information could guide the improvement of beamline setup for optimal lasing performance. We therefore propose an S-band parallel-coupled TDC, in which two chains that deflect beam horizontally and vertically are independently fed by waveguides and variable polarization can be obtained by adjusting their relative amplitude and phase. This design offers several advantages, including tunability, single-frequency operation, compactness, and high shunt impedance. In this manuscript, physical and mechanical design of this TDC as well as the planned proof-of-principle experiment will be presented in detail.

        Speaker: Jiahang Shao (Institute of Advanced Science Facilities)
      • 14:20
        Design of beam collimator control system for HEPS 1h 30m

        The primary function of the HEPS (High Energy Photon Source) collimator is to intercept lost particles induced by the Touschek effect, thus localizing beam loss and reducing it outside the collimator region. It also acts as a dump in emergency situations to meet equipment protection requirements. The collimator control system utilizes EtherCAT bus technology for precise motion control of the scraper. It interfaces with the EPICS system through modbusTCP, enabling remote operation from the HEPS control room. Due to its location in a high-radiation zone, the control system's drive components were selected for their special radiation resistance. On-site testing confirmed stable, precise movement of scraper meeting design requirements, and smooth operation of the remote control system.

        Speaker: Shutao Zhao (Institute of High Energy Physics)
      • 14:20
        Design of beam energy adjustment system for heavy ions testing of space electronics 1h 30m

        Electronic components in spacecrafts and satellites are subjected to impact of high energy particles and heavy ions. Radiation damage of semiconductor electronic devices depends on linear energy transfer (LET) of the particle in semiconductor material which the device is fabricated of. During radiation testing of electronic components for space applications in particle accelerators we have limited set of ions with fixed energies and LET values due to complexity of adjustment of accelerator systems. According to standard test methods it is necessary to perform tests for several LET values in range from 1 to 100 (MeVcm^2)/mg. It is possible to e nhance available LET range using special screens with different thickness (degraders) to decrease initial energy of particles and adjust LET value without reset of the accelerator for another ion type or energy. It can significantly reduce complexity and duration of test processing. In this work by numerical calculations we have designed a set of degraders, which enable us to obtain almost any LET value from 1 to 100 (MeVcm^2)/mg in silicon devices using only four ion types with fixed energies that is acceptable for all test procedures.

        Speaker: Alexander Bakerenkov (Branch of JSC URSC - ISDE)
      • 14:20
        Design of data transmission scheme based on RDMA 1h 30m

        With the development of precise radiotherapy, high-throughput data transmission has become a critical component of beam diagnostics, i.e. for closed orbit feedback in the synchrotron, beam profile images captured with view screens, and medical images generated at the therapy terminal. As the volume of generated measurement data rapidly increase, the data transmission mode that utilizes traditional Ethernet protocol can not meet the transmission performance requirements. To break the bottleneck, this paper designs a prototype data transmission system based on RDMA technology. By directly transferring memory data between hosts, the system bypasses the operating system kernel and CPU intervention, thereby minimizing transmission latency and enhancing data throughput. The system utilizes the RoCE v2 network protocol and is implemented through the libibverbs dynamic link library to establish stable RDMA sessions and develop corresponding network programs. It uses TCP sockets to exchange control information, ensuring that both parties reach a consistent state before data transmission. Performance evaluations indicate that the network transmission scheme proposed in this paper offers lower latency, higher throughput, and reduced CPU usage compared to schemes using the TCP protocol. Additionally, the optimization of resource management strategies such as the use of Multithreaded Development and Shared Receive Queue ensures the efficient and dynamic management of system resources.

        Speaker: Yuqiao Zhang (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Detailed bench investigations and comparison of four low-light cameras 1h 30m

        Sensitive cameras are frequently operated to record low-light processes such as Beam Induced Fluorescence or optical transition radiation for transverse profile determination. We compared four cameras based on different principles: Firstly, we investigated an Image Intensifier equipped with a double MCP (producer ProxiVision); secondly, an electron-multiplied CCD (emCCD Teledyne Princeton Instruments ProEm+:512B); and, thirdly, sCMOS cameras (producer PCO.edge4.2bi and Teledyne Kinetix 22). LEDs generate light pulses within a wavelength range of 385 to 500 nm and a duration of 0.03 to 8 ms to vary the photon flux. Moreover, the spatial resolution is compared. The image intensifier is the most sensitive camera type and provides very low noise; however, the method provides only a limited spatial resolution. The investigated emCCD camera has a comparable sensitivity but provides a better spatial resolution. The sCMOS cameras provide a factor of about 5 to 10 lower sensitivity depending on wavelength. A quantitative comparison of signal-to-noise ratios and statical fluctuations for several wavelengths will be presented.

        Speaker: Peter Forck (GSI Helmholtzzentrum für Schwerionenforschung GmbH)
      • 14:20
        Diagnostics visible beamline at SESAME Storage Ring 1h 30m

        Visible light range of Synchrotron radiation is a versa-tile diagnostics tool for accelerator studies and measurements. SESAME’s storage ring has a dedicated diagnostics visible light beamline from 6.5-degree beam port of bending magnet source point. The beamline will host in future a time-correlated single photon counting unit to measure the bunch filling pattern, fast gated camera and a streak camera for longitudinal diagnostics. Recently, the beamline has been extended to be operational from out-side the tunnel (dedicated hutch) to allow more flexible studies with direct source imaging and a double-slit interferometry for beam size measurement and study trans-verse instabilities. In this paper we give an overview of the design of the beamline, modifications and present first results.

        Speaker: Hussein Al-Mohammad (Synchrotron-light for Experimental Science and Applications in the Middle East)
      • 14:20
        Directly driving GHz-range power amplifiers with RF systems-on-chip for the SLS 2.0 longitudinal multibunch feedback 1h 30m

        In the past, the longitudinal multibunch feedback (MBFB) at the Swiss Light Source (SLS) storage ring had used an analog upconverter to translate the output signal of a 500 MSample/s DAC to the 1.25-1.5 GHz operation frequency range of the longitudinal MBFB kicker magnet and its power amplifier. For SLS 2.0, we have investigated the possibility to drive the power amplifier of a newly designed kicker (operating at 1.75-2 GHz) directly with the multi-GHz / multi-GSample/s DACs of an RF System-on-Chip (RFSoC). First lab test results with the new SLS 2.0 kicker magnet and its power amplifier are presented. Related methods for RFSoC-based bunch-to-bunch crosstalk compensation in the presence of transient beam loading and 200ps range arrival time variations along the bunch train are also presented. Moreover, the latest status and plans for our MBFB firmware/software implementation on an RFSoC will be given.

        Speaker: Pedro Baeta Neves Diniz Santos (Paul Scherrer Institut)
      • 14:20
        Experience with PSI’s Main Ring Cyclotron Long Radial Probe 1h 30m

        A Long Radial Probe is a device used to measure the transverse beam profile in a cyclotron along its radius. The current iteration of the probe was installed in the PSI Main Ring Cyclotron in 2022. After a successful start, the probe encountered issues due to strong coupling with RF fields leaking from the cavities, which resulted in the breakage of the carbon fibers. A series of corrective measures were attempted, but the initial results were inconclusive. This paper discusses the challenges faced and presents the experiments and thermal calculations that provided insights into the RF heating issue.

        Speaker: Dr Mariusz Sapinski (Paul Scherrer Institut)
      • 14:20
        Halo monitor for high-intensity hadron beams based on supersonic gas curtain 1h 30m

        Although there is no clear definition of beam halo in particle accelerators, it is generally regarded as particles outside of the beam core with an intensity level of less than 10-5 or 10-6 of the peaks. In high-intensity, high-power hadron accelerators, the presence of halo particles may cause emittance growth and beam loss, difficulties in beam control and collimation, increase the noise of detectors, and cause activation or even damage to accelerator components.
        To understand the halo dynamics, experimental studies are essential, but the required detection techniques are often too limited and do not meet the required high dynamic range.
        In this contribution, a supersonic gas curtain-based profile monitor is considered for beam halo measurement in high-intensity, high-power hadron accelerators. This monitor is based on the beam gas curtain (BGC) monitor, successfully used in the Large Hadron Collider. Instead of a broad curtain with uniform density, a new concept with two shorter curtain segments which can be adapted to the shape of the beam core and aim at the halo particles only is applied. The monitor design and operating principle will be presented, and the anticipated integration time, signal intensity and dynamic range will be discussed, as well as opportunities for increasing the sensitivity by incorporating micro-channel plates or the Timepix detector.

        Speaker: Hao Zhang (Cockcroft Institute)
      • 14:20
        High performance generic beam diagnostic signal processor for SHINE 1h 30m

        A generic signal processor has been developed for beam diagnostic system in SHINE. The stand-alone processor is used for the signal processing of stripline BPM, cavity BPM, cold button BPM, beam arrival measurement, bunch length measurement and other diagnostic systems. The main core is a SoC FPGA, which contains both quad-core ARM and FPGA on a chip. The ARM runs LINUX OS and EPICS IOC, and FPGA performs peripheral interfaces and high-speed real-time signal processing. An FMC carrier ADC board is mounted, which can sample 4 channels input signal with a maximum sampling rate of 1GSPS. The processor is equipped with a White Rabbit timing card, which can realize 1MHz high repetition rate synchronous measurement. Lab test results and on-line beam tests prove that the processor has high performance. This paper will introduce the processor development and applications on SHINE.

        Speaker: Yuxin Han (Shanghai Institute of Applied Physics)
      • 14:20
        High-resolution quad-channel picoammeter: characterization and commissioning 1h 30m

        To address the high demand for precise low current measurements at the Sirius accelerator and its beamlines, a quad-channel high-resolution Ethernet picoammeter has been designed*. The instrument can measure currents ranging from picoampere to milliampere across eight selectable ranges, featuring integrated ADCs enabling sample rates of up to 2 ksps and synchronization capabilities. This work aims to describe the design, characterization, and calibration results of the instrument. Special attention will be given to evaluating trigger latency, synchronization outcomes, as well as the device’s installation and commissioning at beamlines, particularly for critical applications like on-the-fly scanning experiments. Furthermore, we will explore the interplay between trigger period, digital filter bandwidth, and front-end analog bandwidth to optimize signal-to-noise ratio in specific applications.

        Speaker: Fernando Cardoso (Brazilian Synchrotron Light Laboratory)
      • 14:20
        High-speed ADC and high-speed DAC MicroTCA.4 AMC-RTM pair for a multiple of diagnostics and feedback implementations 1h 30m

        We present the MicroTCA.4 electronics, an AMC-RTM pair, for direct sampling of wideband signals with high-speed ADCs, versatile digital signal processing with a SoC FPGA and driving of wideband signals with high-speed DACs. Its core component is the Zynq UltraScale+ RFSoC Gen 3. The RFSoC IC was mainly designed for the telecommunication and RADAR systems, however, it is also planned for man-ifold scientific experiments, which are shortly introduced in this paper. Not only a multiple of diagnostics can be implemented, but also wideband feedbacks due to driving capabilities of DACs.
        A hardware architecture is presented, which provides in-formation how the modules can be set up and configured for a particular application. The performance and functionali-ties are discussed with special focus on system noise, which is a great importance for high-precision scientific research.

        Speaker: Szymon Jablonski (Deutsches Elektronen-Synchrotron)
      • 14:20
        Integrating InfluxDB and Grafana in a Dockerized CA EPICS Monitoring System 1h 30m

        A data monitoring system based on CA and EPICS designed for particle accelerators is proposed, which leverages Docker containers for deployment and integrates InfluxDB for data storage and Grafana for data visualization. The Data Collection Engine built with Python gathers data through EPICS Channel Access, caches it temporarily, and stores it permanently in InfluxDB. A two-level cache design is used to optimize data access. The monitoring system also offers a web application for configuration management and a web application for online data access and visualization in real-time, which provides a powerful and user-friendly solution for data collection, storage, visualization, and management in particle accelerator experiments.

        Speaker: Mr Ziyang Qi (Harbin Institute of Technology)
      • 14:20
        Long-term performance of the extended pulsed optical timing system 1h 30m

        The optical timing system of the FERMI facility underwent a significant upgrade to accommodate requests for additional pulsed links for remote lasers or diagnostic stations. Following the successful completion of compliance tests, the long-term performance of the extended system has been recently evaluated through out-of-loop measurements. In the setup each of the two pulsed subsystems, synchronized to the common optical master oscillator, feeds a stabilized fiber optic link. The relative stability between the outputs has been monitored at a remote location. The results achieved and the challenges encountered during the measurements will be discussed.

        Speaker: Fabio Rossi (Elettra-Sincrotrone Trieste S.C.p.A.)
      • 14:20
        New fast orbit feedback system using MicroTCA-based BPM electronics for the PF-ring 1h 30m

        The upgrade of the fast orbit feedback (FOFB) system is currently underway at the PF-ring. The new FOFB system consists of MicroTCA-based BPM electronics and a feedback control (FBC) unit. The BPM electronics are prepared with the same number as BPMs and synchronously transmit 10-kHz rate beam position data to the FBC unit via an optical data link. The FBC unit immediately calculates the closed orbit distortion from the received position data and performs an inverse matrix operation to correct it. The results are converted to analog signals by fast D/A converters and set to power supplies of the fast steering magnets. The primary goal of the new FOFB system is to archive a closed-loop bandwidth of 100 Hz, which is about 100 times the current system performance. Details on the new BPM electronics and the new FOFB system using them will be presented as well as some initial results obtained during beam tests.

        Speaker: Ryota Takai (High Energy Accelerator Research Organization)
      • 14:20
        New graphical application for high-level synchrotron control with particular emphasis on the correction module 1h 30m

        SOLARIS, as a big-science facility, is obliged to provide the best possible conditions for conducting research. Due to the complex nature of synchrotron subsystems, we have met our needs and created the most convenient control system possible. The result of our work is a new graphical application for operators offering high level control over the most crucial subsystems of the synchrotron during beam injection and ramping. Moreover operator has now possibility to manage newly implemented mechanism for beam correction at one place. Application was developed in Python based on Tango Controls framework and PyQt library.

        Speaker: Maciej Mleczko (National Synchrotron Radiation Centre)
      • 14:20
        New wire scanner at SXFEL 1h 30m

        In the past year, the wire scanner at SXFEL is upgraded to a new firmware. Unlike the previous version, where a target frame is equipped with tungsten wires in three directions, the new system uses horizontal and vertical independent scanning methods. The beam loss detector adopts plastic scintillator fiber, and the PMT module is also designed with a Raspberry PI for dynamic signal conditioning. The detailed design is described in this paper.

        Speaker: Fangzhou Chen (Shanghai Synchrotron Radiation Facility)
      • 14:20
        Non-destructive beam profile measurements with an Ionisation Profile Monitor (IPM) based on Timepix3&4 Hybrid Pixel Detectors (HPDs) 1h 30m

        Beam Gas Ionization monitors have been in operational use in the CERN PS for two years now, and they were installed in the SPS this year. An overview of the operating principal of the instruments is presented, followed by an update on their development. The mechanical design has been simplified and the Timepix3 devices are now mounted individually for easier assembly and maintenance. Reliability and availability have been improved with a new radiation-hard readout, using the GBTx and bPOL12 devices. Performance has been improved with a SoC Back-End making good use of both the FPGA and the Processing System. We have worked to improve the calibration of the instruments, equalization can now be performed in-situ and we have a procedure to calibrate the response between the four detectors. This paper also presents some example results from the instruments and describes our plans for future developments.

        Speaker: Mark McLean (European Organization for Nuclear Research)
      • 14:20
        Optimized design of an consecutive double-slit emittancemeter for the c-band photocathode rf gun 1h 30m

        To enhance the performance of the next generation of X-ray free electron lasers (XFEL), it is essential to produce a high quality electron beam with a low emittance, for instance, below 0.2 mm-mrad for a 100 pC bunch charge. In order to demonstrate the fundamental techniques required for future FEL facilities, a C-band photoinjector test facility has been constructed aligning with the Southern Advanced Photon Source (SAPS) pre-research project. An emittancemeter based on the consecutive double-slit-scan concept has been proposed and designed for determining such small emittance. This paper presents the further optimization of the primary parameters of this emittancemeter employing numerical simulations in the presence of the measured motion accuracy and the expected observation resolution.

        Speaker: Weiwen Chen (Institute of High Energy Physics)
      • 14:20
        Orbit feedback system in SOLARIS synchrotron final step implementation and first measurements 1h 30m

        SOLARIS, a third-generation synchrotron radiation source in Kraków, Poland, is dedicated to providing high-brilliance X-ray beams for various scientific disciplines. The successful operation of a synchrotron radiation facility heavily relies on precise control of the electron beam orbit within the storage ring. Orbit deviations, even on a small scale, can adversely affect beam quality, leading to decreased performance and efficiency of experimental setups. To mitigate these effects, an Orbit Feedback System is essential, providing correction of orbit deviations. In this study, we present the implementation of an enhanced Orbit Feedback System consisting of fast and slow orbit correction systems as well as RF drift compensation. System consists of feedback algorithms calculating corrective actions of the actuators (fast and slow correction magnets) based on beam position measurements. We also present first measurements and tests for the system showing its capabilities.

        Speaker: Roman Panas (National Synchrotron Radiation Centre)
      • 14:20
        Overview of SLS 2.0 beam based feedbacks and BPM system 1h 30m

        For the ongoing upgrade of the Swiss Light Source (SLS) storage ring, the previous ageing beam-based feedbacks and beam position monitor (BPM) systems are replaced by newly developed versions, where beam commissioning is planned to start in January 2025. Feedbacks include the fast orbit feedback (FOFB), transverse and longitudinal multibunch feedback (MBFB), and filling pattern feedback (FPFB). In this contribution, we give an overview of the architectures and development/production status of these feedbacks and of the BPM system, including latest pre-beam test results.

        Speaker: Boris Keil (Paul Scherrer Institut)
      • 14:20
        Physical design of an online beam monitor for heavy-ion single event effects 1h 30m

        Accurate measurement of flux rate is essential in heavy-ion single event effects tests, but it presents significant challenges for monitoring low energy (5~10 MeV/u) and low intensity (less than 1E6 /s) heavy-ion beams. In this paper, we propose a novel detector that enables real-time monitoring of flux rate by simultaneously measuring the beam intensity and profile using secondary electrons on both the front and back surfaces of thin foils. The confinement of sec-ondary electrons through electric and magnetic fields is achieved, with CST simulation has been utilized to validate the method. This approach offers several ad-vantages over conventional methods, including high space and time resolution, reduced mass thickness, and multi-parameter measurement capability.

        Speaker: Di Wang (Northwest Institute of Nuclear Technology)
      • 14:20
        Preliminary design consideration for CEPC fast luminosity feedback system 1h 30m

        Future large high-luminosity electron-positron collid- ers such as Circular Electron Position Collider (CEPC), and Future Circular Collider (FCC-ee) require nanometre-sized beams at the interaction point (IP). The luminosity is very sensitive to the beam orbit drifts at the IP. It is essential to have a fast luminosity feedback system at the IP to maintain optimum beam collision conditions and prevent a luminosity degradation due to orbit drifts in the presence of mechanical vibrations and dynamical imperfections.We considered two possible methods for this purpose for CEPC: one based on measurements of the luminosity and the other based on measurements of the beam orbits around the IP. In this paper, we present the preliminary design consideration for a fast luminosity feedback system at the IP of CEPC.

        Speaker: Meng Li (Chinese Academy of Sciences)
      • 14:20
        Research on neutron instrument streaming data processing at CSNS 1h 30m

        The China Spallation Neutron Source (CSNS) is the fourth established pulsed spallation neutron source in the world. With the construction and operation of multiple new neutron instruments, a new generation of streaming data transmission solutions based on message middleware has been formally implemented. This paper presents a streaming data readout and processing software designed to meet the data processing needs of neutron instrument experiments, with a focus on high throughput, high customization, and flexible experimental data analysis. The software has been tested and validated on several neutron instruments at CSNS and is gradually being applied in instrument experiments.

        Speaker: Peixun Shen (Institute of High Energy Physics)
      • 14:20
        Research on visualization and indexing of data based on the ELK stack 1h 30m

        This paper presents a comprehensive solution for the real-time collection and analysis of BPM telemetry data using Kafka and the ELK stack. It includes the transmission of PV variables from BPM electronic devices to the Kafka message queue, thus realizing a powerful and scalable data streaming process. By retrieving JSON formatted data from Kafka using the ELK stack, efficient data indexing and visualization in Kibana are achieved. The paper details the architectural design, implementation details, and the advantages of using Kafka as a BPM data dissemination center. This integration not only enhances the performance and reliability of the data processing pipeline but also provides physicists and engineers with powerful tools for the real-time visualization and monitoring of BPM data. Our approach has shown significant improvements in data accessibility, searchability, and real-time analytics, offering profound implications for future research and development in the instrumentation and diagnostics of particle accelerators.

        Speaker: Dr Yukun Li (Institute of High Energy Physics)
      • 14:20
        Slow control system of CEE-TPC 1h 30m

        The Time Project Chamber (TPC) serves as the core detector of the CEE spectrometer, which accurately measures dE/dx, momentum information, and charged particle tracks in the final state of large angularly separated reaction products of nuclear reactions at the Cooling Storage Ring External-target Experiment (CEE) at the Heavy Ion Research Facility in Lanzhou (HIRFL). It is used to investigate scientific questions related to the phase structure of low-temperature, high-density nuclear matter and the asymmetric equation of state of high-density, low temperature nuclear matter. A slow control system (SCS) was designed and implemented using the Experimental Physics and Industrial Control System (EPICS) software toolkit to monitor and control the TPC's operation, front-end electronics and environmental conditions in real time in order to achieve precise position and time measurements with this detector. Approximately 6000 control and monitoring information exchanges have been implemented through the process variables (PVs) in this architecture. In this paper, we describe the design of the SCS, its hardware and software components, commissioning and operation, as well as its performance.

        Speaker: Min Li (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Superconducting solenoid optimization and fields measurement at ELBE 1h 30m

        In order to reduce the projected transverse beam emittance, a solenoid is usually used at normal conducting as well as superconducting radio frequency (SRF) photoinjectors. At the ELBE SRF Gun-II, a superconducting solenoid is located inside the gun´s cryomodule about 0.1 m far from the end of the gun cavity. The solenoid has a longitudinal magnetic field on the axis with a Gaussian-like shape and an effective length of 0.042 m. To determine the beam aberration due to the anomalous, weak quadrupole fields of the solenoid, we measured and analyzed the multipole fields of the solenoid. In this paper, two different multipole magnetic field analysis methods are presented. We also calculated the effect of these fields on the beam emittance. Based on these studies, a group of quadrupole correctors has been installed downstream in the beamline. A comparison of the experimental findings for quadrupole field correction and simulation will be given. For beams with relatively large diameters, the spherical aberrations of the solenoid can increase the emittance significantly. For that reason, an improved solenoid design meets the mechanical and cryogenic demands.

        Speaker: Shuai Ma (China Academy of Engineering Physics, Institute of Applied electronics)
      • 14:20
        Synchronization of Peking University THz FEL 1h 30m

        Peking University plans to conduct experimental research on a THz FEL (Terahertz Free Electron Laser) amplifier using a DC-SRF (Superconducting Radio Frequency) electron gun. The DC-SRF electron gun, which is capable of generating high-quality electron beams with high repetition rates and low emittance, is suitable for use in large scientific facilities such as FELs and ERLs. The experimental setup of the THz FEL amplifier mainly includes a 1.3GHz DC-SRF electron gun, a 2.856GHz RF (Radio Frequency) deflection cavity, a 2.4 GHz cavity-based Beam Arrival Monitor (BAM), a 1.3 GHz 2×9 Cell superconducting accelerator module, as well as photocathode drive laser systems and THz seed light systems. The two laser systems have repetition rates of 81.25 MHz and 100 MHz, respectively. Since the operating frequencies of the components on the THz FEL amplifier device are not identical and some frequencies do not have a multiple relationship, clock generation schemes based on PLL (Phase-Locked Loop) or mixers cannot fully meet the experimental requirements. Therefore, we have employed DDS (Direct Digital Synthesis) to generate the key frequencies. Additionally, to ensure the normal operation of the BAM, signal detection and processing of the BAM signals have been implemented based on the KC705 and FMC150 platforms.

        Speaker: Xiang Zhang (Peking University)
      • 14:20
        The design and ideas of non-destructive ionization profile monitors for HIAF synchrotrons and future applications 1h 30m

        More than 4 Ionization Profile Monitors (IPM) have been mounted in HIRFL, which play an important role in the beam optics optimization, electron cooling research, and ion-electron recombination study so on since 2016.
        To meet the profile needs of HIAF project with multiple beam species and high dynamic challenges, mainly two kinds of IPM structure have been chosen. At first, 5 IPMs equipped with the Micro Channel Plates (MCPs) 、Phosphor screen (P46) and camera acquisition have been deployed in Booster Ring (Num. 3) and Spectrometer Ring (Num. 2), which use discrete electrodes for precisely high voltage supplying and can achieve a good spatial resolution around 50 µm. There is also another IPM designed without a P46 and camera for the electron-photon conversion and capture, but a ceramic anode and the fast multi-channel electronics instead. The purpose is to measure a fast turn by turn profile with a least 64 MHz sampling rate for machine studies.
        Some new features and experiments have also been performed at IMP, like using an IPM for transverse emittance measurements. A compact IPM with one cage measuring horizontal and vertical profiles has also been built and tested, which shows good results under a constraint magnet filed. And a new prototype based on the ionization products captured by a microstrip line or coaxial 50 Ω anode is proposed to measure bunch shapes. It’s for sure that the ionization mechanism or yields can be explored more values in the beam instrumentation.

      • 14:20
        The design of SILF fast orbit feedback system 1h 30m

        The Shenzhen Innovation Light Source Facility (SILF), as a 4th light source, is an accelerator-based multidiscipline user facility planned to be constructed in Shenzhen, Guangdong, China. The accelerator complex is composed of a 200 MeV linac, a booster with ramping energy from 0.2 GeV to 3.0 GeV, and a 3.0 GeV storage ring, and two e-beam transport lines for injection and extraction among accelerators. The circumference of the storage ring is 696 m, which includes 28 hybrid seven-bend achromat (H7BA) lattice periodic units to achieve the emittance below 100 pm·rad. SILF needs to control the beam orbit change within 10% of the cluster size within a certain frequency. In order to meet the beam orbit stability requirements, it is necessary to establish a fast orbit feedback (FOFB) system with field programmable gate arrays (FPGA) to reduce feedback latency and increase bandwidth. The FOFB system adopt 28 sub-stations with the same hardware and software function to obtain bias-data from the beam position monitors (BPMs) data using 2.38Gbps in the SFPs and send correct-data to the fast corrector power supplies using a serial point-to-point link around the storage ring, and each substation share BPMs data with daisy-chained using of 10Gbps in the SFPs. This paper introduces the FOFB system design outline and progress. Some technical plans and schedules are also discussed.

        Speaker: Mingtao Kang (Institute of Advanced Science Facilities (IASF) PRC - Shenzhen, Guangdong 518100)
      • 14:20
        The development of bunch-by-bunch transverse feedback system at SSRF based on RF direct sampling 1h 30m

        The commonly used bunch-by-bunch transverse feedback system is based on the scheme of analog down-conversion, which down converts the 3fRF beam signal to the baseband with a phase adjusted local oscillator. The system contains a large number of analog devices, which make the system complex and vulnerable to environment changes. Today, sampling the high frequency signal directly with high performance ADC is available. A new bunch-by- bunch feedback system based on RF direct sampling is under development at SSRF. The new system structure is much simpler compared to the traditional one and much powerful. The direct sampling processor has 4 input channels, which can simultaneously process horizontal, vertical, large bunch vertical feedback, and bunch charge measurement. The RF processor has 4 ADC channels (maximum sampling rate is 2.6GHz, bandwidth is 9GHz), 4 DAC channels (maximum frequency is 500MHz). The processor uses Xilinx system-on-chip UltraScale+ MPSoC FPGA. Paper will introduce the system structure, the processor design and performance, FIR filter designing and preliminary tests.

        Speaker: Jialan Pan (1Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China 2University of Chinese Academy of Sciences, Beijing, China)
      • 14:20
        The Large Hadron Collider's beam wire scanner consolidation 1h 30m

        To serve the needs of the High Luminosity (HL) LHC, a consolidation of the beam wire scanner has been initiated. The instrument is a crucial tool for measuring the transverse beam profile by moving a thin carbon wire across the beam. It can only withstand a fraction of the LHC's nominal beam intensity but provides a reference to calibrate other instruments that operate non-invasively at higher beam intensities. Since the start of the LHC, the scanners have provided hundreds of thousands of measurements, but the design has technical limitations that need to be addressed to provide the required reliability and performance for the HL runs. The initial consolidation phase involved testing the injector's acquisition and control electronics in the LHC to assess its suitability for the specific beam conditions. As part of this process, we updated the mechatronic and motion controller. Beam test campaign has revealed higher performance w.r.t the existing system and a higher adaptability to varying beam conditions. Simultaneously, we are developing a novel actuator that uses a permanent magnets-based coupling replacing the standard bellows and long arm that limits the performance and induces vibrations. Before testing this new concept with beam, we have developed a calibration bench to evaluate the mechanism’s precision and accuracy of the wire position determination. This contribution presents the 2023 beam and laboratory tests as well as the electromechanical developments.

        Speaker: Jonathan Emery (European Organization for Nuclear Research)
      • 14:20
        The project of Kirkpatrick – Baez focusing system for beam diagnostics on the SKIF 1h 30m

        The Siberian Ring Radiation Source (SKIF) is an upcoming 4th-generation SR source under construction in Novosibirsk, Russia. The designed beam emittance for SKIF is 75 pm-rad, which corresponds to a beam size of 6 micrometers at the observation point within the dipole magnet. The transverse beam dimensions are essential parameters for tuning and reliable operation of the facility. The SKIF diagnostic suite includes a double-slit interferometer operating in the ultraviolet region of the spectrum. This device's spatial resolution should be sufficient to measure the radial size of the beam to an accuracy of 10 percent. These diagnostics will be used during the commissioning of SKIF and afterwards. Although an additional source of information on beam dimensions and dynamics would be desirable for assurance, taking into account the record designed value of beam emittance. The application of X-ray optics and the Kirkpatrick-Baez focusing system seem to be the most suitable options. The article discusses the project of this system, which will acquire X-rays from a SKIF dipole magnet. Simulations of the heat load on the mirrors, means of compensation of thermo-induced surface distortion (thermo-bump) and the spatial resolution of the KB system are described. The choice of scintillator screens, expected temporal resolution, and sensitivity of the diagnostics are discussed as well.

        Speaker: Oleg Meshkov (Budker Institute of Nuclear Physics)
      • 14:20
        The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance 1h 30m

        The SKIF, a fourth-generation synchrotron radiation source is being constructed in Russia. This installation has an ultra-low emittance, allowing for high beam intensity in various scientific and technological fields. A crucial aspect of SKIF is its availability of diagnostic instruments that measure the beam transverse dimensions. This will allow for minimizing the emittance during operation and comparing it with a calculated value. This comparison is critical for determining whether the physical setup meets the design specifications. In addition to measuring the transverse dimensions of the beam, it is also important to observe the behavior of the longitudinal profile and measure its parameters with good accuracy.
        Since the calculated emittance of 75 mrad corresponds to the beam sizes of less than 8 microns at the radiation output sites, a diagnostic complex was developed as part of the working project, including a beam size monitor based on a double-slit interferometer. Observation and measurement of the longitudinal distribution of the beam will be carried out using mutually complementary devices, such as a streak camera and electron-optical dissector.

        Speaker: Victor Dorokhov (Russian Academy of Sciences)
      • 14:20
        The study of beam dynamics at the VEPP-2000 collider using a gated camera 1h 30m

        The Nanogate-38 gated camera with a temporal resolution of 60 nanoseconds was used to measure the transverse beam dimensions in the BEP booster and the VEPP-2000 electron-positron collider. The camera was used in combination with a double-slit interferometer to measure the vertical beam size and with projection optics to construct a transverse beam profile in single-turn mode. Some beam characteristics were measured, such as decoherence time, radiation damping time and fast attenuation time. The purpose of these experiments was to investigate the possibility of using this camera to measure the transverse dimensions of the beam and its emittance, as well as to conduct experiments on accelerator physics at the SKIF synchrotron radiation source.

        Speaker: Maksim Timoshenko (Budker Institute of Nuclear Physics)
      • 14:20
        The upgrade of the target multiwire profile monitor for the CSNS-II project 1h 30m

        The beam power is lifted up to 500 kW for the phase II of the China Spallation Neutron Source (CSNS-II) project, which is five times the power of CSNS-I. At the CSNS, the neutron beams are generated by the spallation reaction of 1.6-GeV protons striking on a tungsten target. The multiwire profile monitor (MWPM) in front of the proton beam window is the only instrument for long-term monitoring of proton beam distribution when the protons are delivered to the spallation target. The wire interval of the target MWPM of CSNS-I is 7 mm, which is slightly sparse for beam profile measurements during the beam operation in recent years. To ensure the precisely monitoring and provide accurate signal for the Machine Protection System (MPS) when the beam is abnormal, an upgraded design was proposed and implemented. The design mainly employs the Printed Circuit Board (PCB) technique to route the signal originated from the tungsten wires. Four bias planes comprised of tungsten wires are added to mitigate the crosstalk effect brought about by stray electrons and enhance the secondary emission effect. The minimal wire interval of present design is 2 mm and the whole equipment is more compact compared with the previous one due to the PCB scheme. This paper will detail the design and manufacturing of the CSNS target MWPM.

        Speaker: Tao Yang (Institute of Plasma Physics)
      • 14:20
        THz resonator based electron beam manipulation 1h 30m

        In recent years, with the development of powerful THz source technologies, THz structures are widely utilized for electron beam manipulation, such as acceleration, deflection, compaction and diagnostics. Taking the bunch length measurement as an example, combining with high field strength and high resonant frequency, the THz structure based deflector could reach femtosecond or even sub-femtosecond resolution. In this paper, a 0.1THz Fabry-Perot resonator based structure will be introduced, which could provide time-dependent deflection for short electron beam to resolve the bunch length with high resolution. By adjusting the relative orientation of the beam direction and the E-field direction of the incident THz source, this structure is also potential for beam acceleration.

        Speaker: Xiaoyu Liu (Institute of High Energy Physics)
      • 14:20
        Transverse emittance measurement using a wire scanner in injector of RAON 1h 30m

        The Rare Isotope Accelerator Complex for ON-line Experiments (RAON) is a facility designed to produce rare isotope beams using the ISOL and IF methods. RAON has a variety of diagnostic devices to measure beam characteristics. Among them, emittance is an important parameter in determining beam characteristics. RAON was applied the Multi-wire scan and Quadrupole scan methods to measure emittance using a wire scanner. These methods of measurement was confirmed through beam generation and transmission simulation at Python. Afterwards, in the beam commissioning, the beam size were measured by 3 wire scanners installed in the MEBT section and the emittance were calculated from the Multi-wire scan and Quadrupole scan methods. In this poster, we presents simulation results and Argon beam emittance measurement results.

        Speaker: Eunhoon Lim (Institute for Basic Science)
      • 14:20
        Transverse feedback system commissioning for hybird operation mode in SSRF 1h 30m

        In SSRF phase II upgrade project, , a specified hybrid bunch was designed to be injected up to 20mA in Hybrid Filling Pattern. Although it is currently unclear to what extent the transverse instability would affect the accumulation of the hybrid bunch current , the beam-line station still hopes to obtain higher luminous flux. For this purpose, an independent feedback loop has been added to the transverse feedback system to suppress the transverse oscillation caused by the hybrid bunch. This paper would describe the system commissioning and related experiment.

        Speaker: Ning Zhang (Shanghai Advanced Research Institute)
      • 14:20
        Transverse feedback to damp collective beam instabilities, past, present and future 1h 30m

        tarting with my first experience of the transverse feedback damper in the KEK 12 GeV PS in 2005 - 2006, where we tested with analog system and in addition digital control-ler from SPring-8 team. Since then, digital systems have come to cover almost all the machines. In J-PARC MR bunch-by-bunch transverse feedback system had been introduced with a collaboration at the proton beam power around 150 kW in 2010. The weaknesses of this system quickly became apparent. It can damp only the center-of-mass motion of each bunch. It could not suppress intra-bunch betatron motion with different betatron phase in a different longitudinal bunch position. This happens in the case of a non-zero chromaticity. Then the intra-bunch feedback system was introduced in 2014 with a proton beam power of approximately 250 kW and has been operating successfully to date. But already this system cannot suppress collective beam instabilities in certain chromaticities over proton beam intensity of 2 - 3E+14 protons per pulse. The higher the sampling rate, the higher the damp-ing efficiency. This system is currently under development.

        Speaker: Takeshi Toyama (High Energy Accelerator Research Organization)
      • 14:20
        Transverse profile measurement of beam for 230MeV proton therapy beamline using scanning wires 1h 30m

        A superconducting cyclotron-based proton therapy system has been developed at the China Institute of Atomic Energy (CIAE). For the 230MeV proton thera-py cyclotron (CYCIAE-230), the beam profile is cru-cial for the adaptation of the proton therapy planning system and an important basis for the commissioning of the beam line. CIAE designed the scanning wires device for the proton therapy facility, which is for high-resolution profile measurements. A readout elec-tronics unit with fA resolution has been included to adapt to the small signal of scanning wires. The data process unit uses ZYNQ-7035 together with 24-bit ADCs and transmits measurement results via MOD-BUS TCP protocol. The diagnostic electronics are placed close to the beam profile monitors (BPM) to reduce the analogue signal transmission distance. To adapt to the mode of the pulse beam during the beam-line commissioning, using the RF system signal trigger sampling, to prevent the signal aliasing. Besides that, a Butterworth filter and a mean filter were used to filter measurement noise. The design of this scanning wire diagnostic system will be reviewed in this paper, to-gether with several measurement results.

        Speaker: Tianyi Jiang (China Institute of Atomic Energy)
      • 14:20
        Troubleshooting the Ionization Profile Monitor (IPM) for CSNS 1.6 GeV RCS 1h 30m

        Non-invasive and turn-by-turn beam transverse profile monitoring is essential for the tunning and operating CSNS 1.6 GeV Rapid Cyclic Synchrotron. A residual gas Ionization Profile Monitor (IPM) was designed and installed in RCS for horizontal beam profile measurement. However, several challenges related to electromagnetic interference (EMI), vacuum, and MCP operation in the IPM were identified. The EMI is induced by the beam itself and further accelerator components. An improved Faraday cage was implemented to counteract the EMI issues. In order to achieve the desired MCP gain, a suitable pull-down resistor was incorporated into the MCP power supply circuit. After these improvements, the IPM was commissioned successfully. This paper will describe the challenges of IPM and early beam commissioning results.

        Speaker: Muhammad Abdul Rehman (Institute of High Energy Physics)
      • 14:20
        Two-dimensional Reconstruction by the Multi-strip Ionization Chamber at PREF 1h 30m

        The 60 MeV Proton Radiation Effects Facility (PREF) spent nearly 1 month at the commissioning phase, during which the multi-strip ionization chamber (MIC) at the experimental terminal offered the core parameters, beam spot, scanning area, scanning uniformity, beam flux. However, the projection distribution provided by the MIC loses some information, such as the flux and the uniformity in a selected area less than the scanning area. This paper used a method of two-dimensional reconstruction to provide a 2D uniformity of selected area. Revealing the trace of the pencil beam at a sampling rate of 10 kHz.

        Speaker: Tong Liu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Upgrade of the phase space multiscreen of FERMI Linac 1h 30m

        The measurement of the longitudinal phase space at the end of FERMI linac is one of the most important characterization of the electron beam properties prior to delivery to the FEL lines. It is performed using an RF-deflecting cavity in conjunction with a dipole to spread the beam in time and energy. The beam transverse distribution is then measure with a multiscreen. The original multiscreen installed in 2009 had a large FOV with a 45deg YAG orientation and 1.5MPx camera. An upgrade has been devised to improve resolution, frame rate and robustness to COTR contamination. The upgrade design is based on a COTR suppressing geometry, a dispersion minimizing incidence angle, a double mirror vacuum optical layout and a Scheimpflug camera geometry. The optical distortion has been characterized by using a precision checkerboard target and automatic Matlab nodes detection. This leads to a transformation matrix that is applied at the image server level to the raw image to remove the trapezoidal distortion. The detector is 8 Mpx 10 Gbit/s CMOS camera fiber coupled to the image sever and capable of full frame 50Hz acquisition.

        Speaker: Marco Veronese (Elettra-Sincrotrone Trieste S.C.p.A.)
    • 09:00 09:50
      THA: Longitudinal Diagnostics and Synchronization: THAT (Tutorial) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Hirokazu Maesaka (RIKEN SPring-8 Center)
      • 09:00
        Latest achievements in femtosecond synchronization of large-scale facilities 50m

        This tutorial addresses the realm of electrical, hybrid and specifically optical schemes for achieving a facility-wide synchronisation on the femtosecond level at free-electron lasers (FELs).
        After a brief introduction to the fundamental principles behind FEL operation and the significance of synchronisation for fully utilising their capabilities. Subsequently, it discusses various methods employed to achieve femtosecond-precision synchronisation, including low-noise timing references, different active stabilisation techniques, and advanced feedback algorithms.
        In addition, the tutorial provides an overview of the numerous challenges encountered in femtosecond optical synchronisation and solutions developed to overcome them. It discusses technological developments, such as ultra-stable optical lasers or timing diagnostics both for optical pulses and electron beams.
        Moreover, practical considerations for implementing such systems in FEL facilities are addressed, including stability requirements, scalability, and integration with experimental setups. Results from recent studies highlighting successful synchronisation implementations at prominent FEL facilities are presented.

        Speaker: Dr Sebastian Schulz (Deutsches Elektronen-Synchrotron)
    • 09:50 10:20
      THA: Longitudinal Diagnostics and Synchronization: THAI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Hirokazu Maesaka (RIKEN SPring-8 Center)
      • 09:50
        Cost-effective time-stretch Terahertz electro-optic recorders, by using 1550 nm laser probes 30m

        Photonic time-stretch is a powerful method for recording electro-optic signals with terahertz bandwidth and high repetition rates. The method consist of modulating a chirped laser probe with the signal of interest. Then, the laser pulse is stretched it in time up to several nanoseconds, so that it can be read using an oscilloscope or ADC board. This technique has been shown to be efficient for monitoring the dynamics of Coherent Synchrotron Radiation (CSR) at SOLEIL, and to study electron bunch shape dynamics at KARA. However, the use of this technique has been strongly limited by the need of high bandwidth and costly oscilloscopes required for the readout. We present here a new design that allows a considerable reduction of the required oscilloscope bandwidth. A key point consists of using the 1550 nm wavelength for the probe. We will also present results obtained at SOLEIL, where THz pulses have been recorded, in single-shot and at MHz repetition rates, using an oscilloscope and ADC board with 1 to 3 GHz bandwidth.

        Speaker: Christelle Hanoun (Université des Sciences et Technologies de Lille)
    • 10:20 10:50
      Morning Coffee Break 30m
    • 10:50 11:50
      THB: Machine Parameter Measurements: THBI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Peter Forck (GSI Helmholtzzentrum für Schwerionenforschung GmbH)
      • 10:50
        High-dimensional and ultra-sensitive diagnostics for electron beams 30m

        Detailed knowledge of particle beam properties is of great importance to understand and push the performance of existing and next generation accelerators. This includes full knowledge of the particle distribution but also the characterization of femtocoulomb (fC) charge beams. We recently proposed a new phase space tomography method to reconstruct the full 5-dimensional (5D) phase space, i.e., the charge density distribution in all three spatial directions and the two transverse momenta. In this contribution, we first present the experimental demonstration of the method at the FLASHForward facility at DESY. This includes the reconstruction of the full 5D phase space distribution of an electron bunch, the use of this measured phase space to create a particle distribution for highly-realistic simulations, and the extraction of the 4D slice emittance. In a second part, we address the characterization of fC charge beams and present a diagnostic device based on silicon strip sensors that is able to measure the profile, time structure, and charge of beams with low charge density. The device demonstrates the applicability of silicon sensors as versatile beam instrumentation devices and can extend the capabilities of existing diagnostic devices to a new charge range.

        Speaker: Sonja Jaster-Merz (Deutsches Elektronen-Synchrotron)
      • 11:20
        Non-destructive beam energy measurement using RF cavity beam arrival time monitor 30m

        Beam energy is a key parameter for free electron laser facilities (FELs). A commonly used nondestructive sys-tem uses a beam position monitor (BPM) to measure the bunch position in a magnetic bunch compressor. At the Shanghai Soft X-ray FEL facility (SXFEL), the chicane stripline beam position method is utilized for this pur-pose. However, this method relies on the initial bunch position before entering the chicane and has a limited linear region. A different non-destructive beam energy system, which measures the bunch flight time using two cavity-based bunch arrival time monitors, has been pro-posed and tested. This paper introduces the development of this system, including design details, build-up, and measurement results. Moreover, it also covers the compar-ison between the two different bunch energy measure-ment methods from several aspects: bunch position-based and bunch flight time-based.

        Speaker: Shanshan Cao (Shanghai Advanced Research Institute)
    • 11:50 12:30
      THB: Machine Parameter Measurements: THBC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Peter Forck (GSI Helmholtzzentrum für Schwerionenforschung GmbH)
      • 11:50
        Laser modulator for SSMB used as a diagnostic tool 20m

        At the Metrology Light Source in Berlin, the concept of Steady-state microbunching (SSMB) is evaluated in a proof-of-principle (PoP) experiment. SSMB has been proposed to deliver kilowatt level average power EUV radiation from an electron storage ring. In the PoP experiment, an energy modulation is impressed onto the electron beam using an infrared laser pulse co-propagating inside an undulator. We show that the beam energy can be measured absolutely by detuning the undulator gap from optimum resonance and observing the intensity of the resulting coherent synchrotron radiation.

        Speaker: Arnold Kruschinski (Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH)
      • 12:10
        Observation and study of space charge effect frequency shifts in high-intensity accelerators 20m

        The China Spallation Neutron Source Rapid Cycling Synchrotron (CSNS-RCS) is the first high-intensity pulsed proton accelerator in China and the fourth in the world. The space charge effect is a key factor limiting power enhancement. Measuring the frequency shift induced by the space charge effect is an important method for studying this phenomenon. In our experiments, we varied the beam current by adjusting the injection pulse length and chopping rate. Using a combination of narrow-band filtering and Fast Fourier Transform (FFT) techniques, we successfully observed a tune shift of approximately 0.02 induced by a beam power of 140 kW. These experimental results were compared with simulation outcomes, showing good agreement.

        Speaker: Yuwen An (Institute of High Energy Physics)
    • 12:30 13:30
      Lunch Break 1h
    • 13:30 14:00
      THC: Longitudinal Diagnostics and Synchronization: THCI (Invited Oral) China Hall 2 (Auditoriium)

      China Hall 2

      Auditoriium

      Convener: Marco Veronese (Elettra-Sincrotrone Trieste S.C.p.A.)
      • 13:30
        Approaching an optimum time resolution for synchroscan streak-camera measurements with visible synchrotron light 30m

        The optical beam diagnostics at the BESSY II light source in Berlin have been improved significantly over the last few years. In particular, the streak-camera system has been extended in precision and sensitivity to allow two-dimensional imaging in time and space for equilibrated and non-equilibrated bunch patterns. In this paper, we prove experimentally and theoretically that we have reached a sub-ps RMS total time resolution using filtered synchrotron light. Detailed simulations, including the different physical time-dispersion mechanisms, show the influence of various band-pass and edge wavelength filters on the resolution. The limits for unfiltered near-visible synchrotron radiation (white-light) and the band-pass filter to achieve optimal time resolution are derived as well, providing a basis for more advanced beam-dynamics studies in the near future.
        (NIMA, 1062, May 2024, 169196)

        Speaker: Marco Marongiu (Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH)
    • 14:00 14:40
      THC: Longitudinal Diagnostics and Synchronization: THCC (Contributed Oral) China Hall 2 (Auditoriium)

      China Hall 2

      Auditoriium

      Convener: Marco Veronese (Elettra-Sincrotrone Trieste S.C.p.A.)
      • 14:00
        Direct measurement of the longitudinal emittance for a proton beam at exit of a radio frequency quadrupole 20m

        Clarifying the longitudinal phase space distribution at the exit of a radio frequency quadrupole (RFQ) is crucial for precise beam tuning to minimize beam loss in a high-power superconducting linac. In this contribution, we introduce a method for direct measurement of the longitudinal emittance of a proton beam at the RFQ exit, which delivers an output energy of 1.51 MeV. Initially, we developed a bunch shape monitor (BSM) inspired by Feschenko’s design, achieving a resolution of 20 picoseconds. To conduct the direct measurement of longitudinal emittance, we integrate this BSM with a waist-to-waist beam transfer matrix, an energy-spread dipole, and a horizontal slit with a 0.2 mm width. The horizontal slit is positioned at the first waist at the dipole’s input, while the BSM wire is situated at the second waist, at the dipole’s output. This arrangement, enhanced by the waist-to-waist transfer matrix, improves the energy spread resolution to 0.01%. Using the BSM wire, we measure the energy spread and horizontal profile. Through adjusting the buncher voltage and synchronous phase, we use dipole and BSM to measure different longitudinal emittances and ascertain the effects of bunching and debunching conditions on the longitudinal phase space. Consequently, this comprehensive direct measurement setup for longitudinal emittance serves to elucidate the impact of RFQ and buncher on the longitudinal phase space distribution within a medium-energy beam transport (MEBT) system.

        Speaker: Yong Zhang (Institute of Modern Physics, Chinese Academy of Sciences)
      • 14:20
        Absolute Characterization of sub-fs Electron Bunch-Length in SwissFEL using a Bunch-Compressor Monitor 20m

        The shot-to-shot and non-invasive monitoring of the electron bunch length in a linac driven Free Electron Laser (FEL) relies on Bunch Compressor Monitors (BCMs). A BCM is designed to detect – and fully integrate in a given wavelength band - the radiation energy spectrum emitted at the threshold of the temporal coherence by the electron beam while crossing the last dipole of a magnetic chicane or a diffraction radiation screen placed just downstream of it. The BCM signal response is hence a direct - albeit non-absolute - function of the electron bunch length and of the beam charge as well. Due to its full non-invasiveness, a BCM is the ideal diagnostics to be integrated into the machine feedback to stabilize the bunch compression. Recently, we presented (*) a formal method for the absolute determination of the electron bunch length from the analysis of the signal readout of a BCM which is equipped with two independent detectors integrating the radiation energy pulse in two different wavelength bands. Theoretical highlights of the method as well as experimental results on the characterization in SwissFEL of electron beams with sub-fs bunch length will be presented in this contribution.

        Speaker: Gian Luca Orlandi (Paul Scherrer Institut)
    • 14:40 15:10
      Afternoon Coffee Break 30m
    • 15:10 15:40
      THD: Longitudinal Diagnostics and Synchronization: THDI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Gero Kube (Deutsches Elektronen-Synchrotron)
      • 15:10
        On-line beam synchronous phase calibration using beam-induced RF signals 30m

        Accurate calibration of beam synchronous phase is essential for the optimal operation of accelerators. Traditional methods, such as the "phase scan method," not only consume significant machine runtime but are also susceptible to environmental disturbances. DESY has introduced a novel method based on "transient beam loading effects" for calibrating synchronous phase. However, this method requires the RF system to operate in an open-loop mode, limiting its applicability in proton linear accelerators. In this paper, leveraging the classical cavity differential equations, we propose a new method based on the steady-state "vector diagram of beam-induced voltage "for calibrating beam phase. This method enables on line calibration of beam phase and beam current under closed-loop operation of the radio-frequency cavities. We validated our approach on the CAFe (the Chinese ADS Front-end proton facility) at the Institute of Modern Physics, China, and the European Spallation Source. The measurement errors for beam current and phase using our method and the beam diagnostic system were 2% and within ±1 degree, respectively. Experimental results confirm the effectiveness of our method as a new solution for on line calibration of beam synchronous phase.

        Speaker: Feng Qiu (Institute of Modern Physics, Chinese Academy of Sciences)
    • 15:40 16:00
      THD: Longitudinal Diagnostics and Synchronization: THDC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Gero Kube (Deutsches Elektronen-Synchrotron)
      • 15:40
        Capacitive pick-up type bunch shape monitors for low-energy ion beams at RAON 20m

        For Time Of Flight (TOF) experiments in the Rare isotope Accelerator complex for ON-line experiments (RAON), specifically at the Korea Broad Acceptance Recoil spectrometer and Apparatus (KoBRA) and the Nuclear Data Production System (NDPS), the beam repetition rate must not be excessively high, and the bunch length needs to be suppressed. The pre-bunching and re-bunching systems will be operational to achieve these objectives. To measure the bunch shapes near the production targets of KoBRA and NDPS without disrupting the beam, we optimized and manufactured capacitive pick-up monitors for installation upstream of the production targets. Furthermore, an algorithm was developed to reconstruct the shape of non-relativistic ion beams using experimental results measured by capacitive pick-up type monitors. An experiment using bunched hydrogen ion beams was conducted to verify the pick-up monitors' capability to measure bunch shapes. This presentation discusses the design methodology, simulation results, and bench tests of the capacitive pick-up monitors for ion beams with non-relativistic speed and nanosecond-order bunch lengths. Additionally, experimental results using hydrogen ion beams are also presented.

        Speaker: Donghyun Kwak (Institute for Basic Science)
    • 16:00 17:30
      THP: Thursday Poster Session: THP China Hall 3

      China Hall 3

      • 16:00
        10-fs-level synchronization of femtosecond laser with RF master oscillator 1h 30m

        Laser-to-RF synchronization plays a crucial role in various scientific and technological domains. It is instrumental in generating high-quality electron beams, producing high-performance FEL pulses, ex-ploring ultrafast dynamical processes, and achieving precise measurements and transmission. Passively mode-locked femtosecond lasers are known for their exceptionally low noise characteristics, particularly in the high-offset frequency range, where jitter remains less than 5 fs from 1 kHz to 1 MHz. Meanwhile, RF master oscillators provide outstanding long-term sta-bility in the offset frequency range. This paper demon-strates that integrating the low-noise performance of passively mode-locked femtosecond laser with the superior stability of RF master oscillator enables the achievement of 10-fs-level synchronization. By im-plementing an RF-based phase-locked loop (PLL) scheme, we achieved an absolute timing jitter of 17.4 fs integrated from 10 Hz to 1 MHz.

        Speaker: Jinguo Wang (Shanghai Advanced Research Institute)
      • 16:00
        A longitudinal phase space measurement using the dechirper composed of corrugated metallic at PAL-XFEL 1h 30m

        We present the experimental results of the longitudinal phase space measurement using the well-known wakefield deflector driven by the dechirper. When the electron bunch travels through the dechirper, electrons at the head of bunch generate the strong transverse wakefield which forces the trailing electrons to be transversely streaked. In such a way, the temporal structure of bunch can be reconstructed by analyzing the distribution of transverse profile at the downstream of dechirper. In the soft X-ray line of the PAL-XFEL (Pohang Accelerator Laboratory, X-ray Free Electron Laser), the dechirper composed of 1.4-meter-long corrugated metallic walls streaks the bunch horizontally via the wakefield. By combining with the bending magnet having the vertical dispersion, the longitudinal phase space of electron beam can be interpreted as the spatial distribution at the screen monitor. We show the results of the longitudinal phase space measurement using the wakefield deflector.

        Speaker: Chang-Kyu Sung (Pohang Accelerator Laboratory)
      • 16:00
        A preliminary design of a Compton polarimeter at BEPCⅡ 1h 30m

        BEPCⅡ is a double ring e+ e- collider running in the tau-charm energy region. We proposal reusing the beamline of a dismantled wiggler magnet to implement a Compton polarimeter detecting scattered γ photons, to measure the self-polarization of the electron beam at BEPCⅡ. As a testbed for future colliders like the CEPC, this would enable resonant depolarization,and thus provide precision beam energy calibration for BEPCⅡ. In this paper, the preliminary design of this Compton polarimeter is presented, as well as the tentative plan for implementation and commissioning in the coming years are shown.

        Speaker: Mengyu Su (University of Chinese Academy of Sciences)
      • 16:00
        A test bench for 324 MHz RF deflectors used in bunch shape monitors for CSNS-II linac upgrade 1h 30m

        Bunch shape monitors based on the transverse modulation of low energy secondary emission elec-trons, will be used in the measurement of longitudinal beam density distribution in the upgrade of CSNS-II linac. A test bench for commissioning the 324MHz RF deflectors used in BSM has been built in the laborato-ry, which consists of a Kimball E-gun, a vacuum chamber for electron optics, an RF stimulator, a 324MHz RF power source, HV power supplies, a bending magnet and a set of MCP+Screen+camera+DAQ. This paper gives the design consideration, some results of the test bench and the continuing CST design of a λ/2 RF deflector.

        Speakers: Quanru Liu (University of Chinese Academy of Sciences), Weiling Huang (Institute of High Energy Physics)
      • 16:00
        Absolute beam current measurement for slow extracted beams at CERN's North Area facility 1h 30m

        The North Area facility (NA), built in the 1970s at CERN, hosts several secondary beam lines for a large variety of physics experiments: Neutrino Platform, Dark matter, high energy physics, R&D, detector validation etc. 400 GeV/c primary proton beams, extracted from the SPS ring, are split along the transfer lines to fire on 4 targets and serve the users with secondary particles such as e-, e+, muons, pions, hadrons, kaons... Within a typical slow extraction scheme of 4.8 s, one gets a spill intensity of about 4E13 protons heading to the splitters. Available beam intensity monitors are ageing fast and are accurate up to 10% only, which is not compatible for future high intensity physics programs and new demanding specifications for the beam instrumentation. In the wake of the NA consolidation project, it is proposed to measure the beam intensity with a Cryogenic Current Comparator (CCC). Such devices installed at FAIR (GSI) and in the Antimatter Factory (CERN) have proven to be operational and having a resolution of a few nA. This paper describes the roadmap and challenges to come for the development of the new CCC.

        Speaker: Jocelyn Tan (European Organization for Nuclear Research)
      • 16:00
        Advancements in beam arrival time measurement for SHINE* 1h 30m

        The jitter of the beam arrival time can significantly impact the synchronization between the seed laser and the electron beam, which will constrain the brightness and stability of the FEL. It is one of the important parameters for beam diagnostics. To align with the SHINE's (Shanghai HIgh repetition rate XFEL aNd Extreme light facility) requirements of a 1MHz repetition rate and a dynamic range from 10pC to 300pC, we developed a beam arrival time measurement system utilizing a cavity probe. This system is capable of achieving a specification of 20fs at a charge of 100pC. Our approach included designing measurement schemes based on intermediate and radio frequencies and establishing a comparative test platform at the SXFEL (Shanghai Soft X-ray Free-Electron Laser Facility). This article will detail the construction of two systems and compare their test results across various charges. It has also been confirmed that the system can accurately measure beam arrival times for charges less than 1pC. A major challenge identified was temperature drift, which significantly affects measurement accuracy and limits the system's application in beam feedback. To counter this, we implemented and evaluated constant temperature controls for the RF cables, demonstrating their effectiveness in enhancing measurement reliability.

        Speaker: Yimei Zhou (Shanghai Advanced Research Institute)
      • 16:00
        Application of Fiber Beam Loss Monitoring System (FBLM) and Scintillator Beam Loss Monitoring System (SBLM) on HEPS 1h 30m

        The High Energy Photon Source (HEPS) is a fourth-generation light source with a beam energy of 6 GeV currently under development by the Institute of High Energy Physics. The Beam Loss Monitor (BLM) system is designed for monitoring beam losses during machine commissioning. Two types of beam loss monitors have been installed in both the booster and storage ring. This paper introduces the principles and composition of these two BLMs, as well as their application in beam commissioning.

        Speaker: Lingda Yu (Institute of High Energy Physics)
      • 16:00
        Autocorrelator device for measuring the duration of the NovoFEL laser pulse 1h 30m

        The Novosibirsk Free Electron Laser (NovoFEL) is a powerful source of narrow-band terahertz and infrared radiation, operating at the Institute of Nuclear Physics of the Siberian Branch of the Russian Academy of Sciences (INP SB RAS). It is based on an accelerator-recuperator system and is one of the main user facilities of the Siberian Synchrotron and Terahertz Radiation Center. In recent years, there has been active work to develop new diagnostics for measuring the parameters of the electron beam in the third stage of the NovoFEL. The laser generates pulses of radiation with picosecond durations in the mid-infrared range of 8-12 micrometers that is the challenge for the diagnostics. This paper describes the development of diagnostic systems for the spectral and temporal characteristics of laser radiation from the third stage of the NovoFEL facility. To record the radiation spectra, a diffraction monochromator was used in conjunction with a bolometric array as a detector. A nonlinear autocorrelator based on ZnGeP2 crystal was developed to measure the temporal profile of the radiation. The correct operation of the autocorrelator was demonstrated in experiments with YAG laser radiation acquired using a nonlinear β-BaB2O4 crystal. The paper presents results from measurements of the spectrum and autocorrelation function for laser radiation from the third stage of the NovoFEL. Self-consistency between the spectrum and autocorrelation functions is demonstrated.

        Speaker: Stanislav Reva (Budker Institute of Nuclear Physics SB RAS & Novosibirsk State University)
      • 16:00
        Beam based alignment by using double correctors 1h 30m

        Beam based alignment is a well-known technique for obtaining a small emittance beam which is critical in an injector of an accelerator or a matching section between two accelerators. The simplest beam based alignment can be performed with a corrector, a quadrupole, and a beam position monitor. This work presents a beam based alignment technique with double correctors located before the quadrupole magnet. The merit function was used to find the corrector settings of each beam based alignment. The measurement results showed that minimum corrector strengths could be achieved to have the ideal beam based alignment by using the fitting results of the merit function.

        Speaker: Changbum Kim (Pohang Accelerator Laboratory)
      • 16:00
        Beam dynamics design of the superconductiong section of a 100 mA superconducting linac 1h 30m

        Beam loss is a critical challenge in the physics design of high power superconducting proton linacs. The challenge is even more acute in linacs that feature high peak intensity and low energy, which has strong space charge effect and RF nonlinear force. In this paper, we study how to achieve a high transmission rate for beam halo particles, commonly a major source of beam loss, via beam halo matching and acceptance optimization. We employ this method of beam loss reduction to improve the physics design of a high power 100 mA superconducting linac which has potential applications in high brightness neutron production.

        Speaker: Man Yi (Advanced Energy Science and Technology Guangdong Laboratory)
      • 16:00
        Beam loss measurement at AichiSR storage ring 1h 30m

        We are developing a system of beam loss monitor at the Aichi Synchrotron Radiation Center, AichiSR in Japan, for accelerator operation stable. AichiSR is a light source mainly for industrial applications with a 1.2 GeV electron storage ring, the circumference of 72 m. It is operated with a beam current of 300 mA at all times by top-up injection. The beam loss measurement uses PIN photodiode BLMs from Bergoz. The BLMs are fixed to beam ducts of the storage ring and the detector outputs are measured with an oscilloscope just after 1 Hz beam injection with using four pulse kickers. Several continuous and strange signal waveforms were observed during a few microseconds of the kickers operation. Since the signals were synchronized with the beam circumference time of 240 ns, we have considered that the signals contain coordinate information of the beam loss in a circumference of the storage ring and derived the stepwise loss distribution of one injected beam. In this presentation, the simple method and results of time-resolved beam loss measurement using a photodiode BLM is discussed and development status of the monitor system at AichiSR is reported.

        Speaker: Masaki Fujimoto (Nagoya University)
      • 16:00
        Beam parameters studies of the CAEP THz FEL as injector for ERL 1h 30m

        The Energy Recovery Linac (ERL) serves as a primary means to simultaneously achieve high energy utilization efficiency, high average beam current, and high-brightness electron beams. The Chinese Academy of Engineering Physics’ Infrared Terahertz Free-Electron Laser (CAEP IR-THz FEL) aims to produce FEL light within the 0.1-125 THz spectrum with updated beam energy and undulators. Another goal of the project is to build Chinese first ERL experimental research platform. The original CAEP THz FEL accelerator will be the injector of the ERL. This paper focuses on the generation and measurement of high repetition rate, low emittance electron beams of the injector, combining numerical simulation optimization with experimental measurements. The beam dynamics of the injector is optimized with ASTRA. The fully beam parameters, including beam transverse emittance, bunch charge, beam energy and energy spread and bunch length are measured and analyzed in detail, which will be used for further ERL beam dynamics design.

        Speaker: Xin Yang (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Betatron stopbands and coupling resonance driving terms characterization at VEPP-2000 collider 1h 30m

        The final-focus solenoids of the round-beam e+e- collider VEPP-2000 can cause stopbands in the betatron tune plane. This specific stopband domain limits the available tune space in the most important region above the integer tunes. We present a study of the combined effect of coupling resonances caused by the decompensated solenoids and the integer-tune parametric resonances. The results are compared with numerical investigations of this combined effect. Presented experimental data includes scanning of the available betatron tune plane domain and evaluation of coupling RDTs using beam oscillation histories from BPMs.

        Speaker: Danil Chistyakov (Budker Institute of Nuclear Physics SB RAS & Novosibirsk State University)
      • 16:00
        Bunch-by-bunch feedback system used as a diagnostic tool for multi-bunch beams in the DAΦNE collider 1h 30m

        DAFNE is an electron-positron collider in operation at INFN-LNF since 2001. Bunch-by-bunch feedback systems installed in each of the two rings allow to store high-intensity and stable beams, by counteracting coupled-bunch instabilities. The feedback systems can be also used as a diagnostic tool able to measure beam parameters which are significant for the evaluation of the instabilities. In this paper, we first describe the acquisition system used to collect the beam data provided by the feedback systems. Then we report recent transverse tune shift and grow-damp measurements with positron beams, performed using the feedback as a diagnostic tool. These measurements helped to characterize the electron-cloud beam instability, which is one of the main factors currently limiting the DAFNE performance. Finally, we describe the first measurements and feedback system setup designed to automatically record turn-by-turn bunch position displacements when a sudden loss in beam current occurs due to any faults in the collider. This tool can be very useful in identifying the causes of these events and performing beam dynamics studies and code validation.

        Speaker: Danilo Quartullo (Istituto Nazionale di Fisica Nucleare)
      • 16:00
        Calibration of beam current monitors at J-PARC accelerator facility 1h 30m

        Accelerators at J-PARC, a high-intensity proton accelerator facility, consists of a 400 MeV linac, 3 GeV RCS, and 30 GeV MR. The RCS is aiming for steady operation with output beam power of 1 MW, while the MR has achieved its initial target of 750 kW by shortening its operating cycle, and further beam tunings and developments are underway to achieve the next target of 1.3 MW. At J-PARC, it is necessary to suppress beam losses to an extremely low level to suppress the activation of the accelerator devices, and thus it is essential to improve the measurement accuracy of beam loss and current monitors. Particularly in MR, with the significant improvement in beam power, there is a need to improve the measurement accuracy of the beam current monitors from 1% at the present. Accordingly, the current monitors have been calibrated regularly, but have not been carried out in a unified manner throughout the accelerators. In this presentation, we will report on the calibration methods and its accuracy.

        Speaker: Kenichirou Satou (High Energy Accelerator Research Organization)
      • 16:00
        Characterization of the PREF slow extraction parameters 1h 30m

        Providing 10 to 60 MeV proton beams, the PREF (Proton Radiation Effects Facility) is dedicated to the displacement damage effect experiments. The slow extracted beams from the synchrotron are delivered to two experimental terminals, which required the flux as constant as possible. To characterize the slow extraction parameters, scintillators and ionization chambers are equipped in the transport line and the terminals. The frequency response reveals the major influencing factor, power supply ripples. The duty factor reached over 90% shows the high slow extraction quality of the new accelerator.

        Speaker: Tong Liu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        DCCT noise and beam lifetime measurement 1h 30m

        Beam lifetime measurements are an important tool to characterize the key storage ring and machine performance parameters. They are usually derived from the dc current transformer (DCCT) data, and their accuracy depends on DCCT noise and data duration period. However, accurate dc current and fast lifetime determination are in contradiction and have to be balanced carefully. In this contribution, a model is presented which relates the relative accuracy in lifetime determination and the DCCT noise with the acquisition time. For the PETRA IV project at DESY (Hamburg, Germany) which aims to upgrade the present PETRA III synchrotron into an ultra low-emittance source, according to this model a lifetime determination to the level of 1% should be possible within 5-6 s acquisition time.

        Speaker: Gero Kube (Deutsches Elektronen-Synchrotron)
      • 16:00
        Design and experiment of an optimized eight-stripline beam energy and energy spread monitor 1h 30m

        In order to achieve nondestructive measurement and feedback of beam energy and energy spread for high repetition frequency Linac, an eight-stripline beam energy and energy spread monitor have been designed to replace destructive monitor sunch as fluorescent screen. Different from the conventional evenly arranged stripline structure, an unevenly arranged stripline layout is proposed to improve the sensitivity. At the same time, impedance transition structures are added to the Feedthroughs and striplines connection parts to further enhance the system sensitivity and resolution. The electronics adopts the method of separating the analog front-end and digital acquisition part from each other, and has the function of bunch-by-bunch measurement and data storage with a high repetition frequency of 1 MHz. The processing of the monitor has now been completed. Experiments show that the position sensitivity with an inner diameter of 63 mm reaches 0.0538 $mm^{-1}$, which is close to the theoretical result of numerical calculation. Compared with monitors of traditional structure, the performance has been greatly optimized.

        Speaker: Qian Wang (University of Science and Technology of China)
      • 16:00
        Design and first results of a cryogenic beam loss monitor installed at the LHC 1h 30m

        The Large Hadron Collider (LHC) is equipped with NiTb superconducting magnets operating at the cryogenic temperature of 2.9 K. A tiny fraction of proton beam at 7 TeV impacting the magnet coils has the potential to generate enough heat, leading to the loss of superconductivity in the magnets. Consequently, it is imperative for machine performance to detect such beam losses before the quench event occurs. To enhance the sensitivity of magnet quench detection through the measurement of beam losses, ongoing efforts focus on the development of cryogenic beam loss monitors. This contribution outlines the design improvements made to a semiconductor-based beam loss detector installed inside the magnet cryostat, positioned just outside the vacuum vessel of the superconductive LHC dispersion suppressor magnets.

        Speaker: Ewald Effinger (European Organization for Nuclear Research)
      • 16:00
        Design and implementation of electron current measurement module for superconducting accelerator 1h 30m

        The electron current measurement module is a key component of the superconducting cryomodule testing platform. Serving as a vital monitoring signal device within the coupler interlock system, this module monitors the electron cloud of high-energy power couplers and waveguide systems to ensure their effective protections. This article details the design and performance testing of the electron current measurement module, highlighting key technologies including anti-interference, weak cur-rent detection, multi-channel signal acquisition and processing, and weak current calibration. This module boasts a large dynamic range, high precision, and multi-channel weak current detection, featuring 32 detection channels with a detection range of nA~10μA. Its detection accuracy surpasses 1nA, and its response time is under 5ms. Additionally, the module's design took into account the impact of ionizing and electromagnetic radiation on its performance to ensure its reliability and stability.

        Speaker: zhiyu wang (SPIC Nuelectronic Company Limited)
      • 16:00
        Design Choices for the Cryogenic Current Comparator for FAIR 1h 30m

        The Cryogenic Current Comparator (CCC) is a superconducting SQUID-based device, which measures extremely low electrical currents via their azimuthal magnetic field. Triggered by the need for nA current measurement of slow extracted beams and weak beams of exotic ions in the storage rings at FAIR and CERN, the idea of the CCC as a diagnostics instrument has been revitalized during the last ten years. The work of a collaboration of institutes specialized on the various subtopics resulted in a large variety of CCC types with respect to field-pickup, magnetic shielding, SQUID types and SQUID coupling. Many of them have been tested under laboratory and under beamline conditions, which formed a detailed picture of the application possibilities for CCCs in accelerators.
        In parallel to CCC detector development the cryogenic support system has steadily been optimized, to fulfil the requirement of a standalone liquid helium cryostat, which is nonmagnetic, fit for UHV application, vibration damped, compact and accessible for maintenance and repair.
        We present the major development steps of the CCC for FAIR. The latest beamtime results are shown as well as recent tests with the cryogenic system. The most promising CCC type for FAIR is the so called Dual-Core CCC (DCCC), which runs two pickups in parallel with independent electronics for noise reduction. The magnetic shielding has an axial meander geometry, which provides superior attenuation of external magnetic noise.

        Speaker: Thomas Sieber (GSI Helmholtzzentrum für Schwerionenforschung GmbH)
      • 16:00
        Design of beam loss measurement electronic at superconducting section in CSNS-II 1h 30m

        The CSNS-II linear accelerator upgrade will adopt superconducting accelerator structures, with the beamline enclosed in low-temperature modules. Detection of beam loss can only be done on the outer surface of the low-temperature modules. The CSNS-II accelerator plans to use a parallel plate multi-electrode ionization chamber as the beam loss monitor (BLM) probe for the superconducting section. The electronic system of the beam loss measurement (BLM) is primarily used for signal conditioning, digitization (ADC), transmission storage as EPICS PV quantities, and providing interlock signals for machine protection based on the output signals from the BLM probes. The main tasks of the development of the beam loss measurement (BLM) electronic system include: signal conditioning of weak current output from the BLM probes in the analog circuit section; and analog-to-digital conversion, digital signal processing, storage, PV quantity publication in the digital circuit section for the front-end analog output signals.

        Speaker: Lei Zeng (Institute of High Energy Physics)
      • 16:00
        Development of a metamaterial-based cavity beam current monitor at HUST 1h 30m

        Non-intrusive cavity beam diagnostic devices offer advantages such as high induced signal and sensitivity. The size of the resonant cavity is inversely related to its operating frequency, resulting in an increase in size at lower operating frequencies, thus limiting its applicability.
        Therefore, exploring how to modify the cavity structure to regulate its internal electromagnetic field distribution and achieve a decrease in operating frequency has become a research topic of significant importance. In current cyclotron-based proton therapy devices, challenges arise from low beam repetition rates and weak intensities. These characteristics make traditional cavity beam diagnostics ineffective, resulting in monitoring blind spots during treatment. To tackle this challenge, this paper introduces a metamaterial-loaded cavity beam current monitor (BCM). Electromagnetic simulations reveal that this approach significantly reduces the size of the cavity under low-frequency operational settings. Moreover, this technique addresses the problem of high energy loss observed in conventional dielectric-loaded cavity BCM, effectively improving sensitivity. The all-metal metamaterial structure also circumvents difficulties associated with processing. This innovative design presents a fresh avenue for exploring the development of compact cavity beam diagnostics suitable for low-frequency operational environments.

        Speaker: Yuexin Lu (Huazhong University of Science and Technology)
      • 16:00
        Development of a method for visualizing the magnetic axis of multipole magnets 1h 30m

        Accelerator technology development requires an increase in the precision of both the manufacturing of magnetic elements and their positioning during accelerator installation. In order to monitor the quality of the magnetic elements created, various methods are used. Most of the methods involve the use of precision stands, so magnetic elements are typically measured immediately after production and the data obtained is used for positioning. However, subsequent possible parameter changes are not taken into account. This work is dedicated to the study of an alternative optical magnetic measurement method*. The method is based on the magneto-optical phenomenon of light polarization plane rotation in optically active media, which allows visualizing the magnetic field projection in a given transverse direction. The use of a geodesic laser tracker as a light source could allow us to apply this method directly during accelerator component positioning, solving the aforementioned problem. Our main goal was to verify the feasibility of the method for determining magnetic axes in multipole magnets. A method for creating an optically active medium was developed, the sensitivity of the technique to magnetic fields was studied, and experiments to verify its accuracy on magnetic components produced for the SKIF photon source were conducted. The results of this study provide insight into the potential of this method and indicate directions for its future development.

        Speaker: Stanislav Reva (Budker Institute of Nuclear Physics SB RAS & Novosibirsk State University)
      • 16:00
        Development of Analog circuit in BLM System at RAON 1h 30m

        The Rare Isotope Accelerator complex for ON-line experiments (RAON) is a heavy ion accelerator with a maximum beam power of 400 kW. The Beam Loss Monitor (BLM) system has been developed to investigate the amount of beam loss in the accelerator. BLM system utilizes current read-out system, analog pre-amp circuit and BLM devices. These devices comprise three types: Proportional Counter, Plastic Detector and Beam Loss Collector (BLC). Bench test was conducted to develop the analog circuit to measure current with a DAQ board. BLM devices have been installed and they are undergoing commissioning. This poster presents the bench test results and the preliminary results during the beam commissioning with Argon beam current of 50 uA.

        Speaker: Sungjune Lee (Korea University)
      • 16:00
        Development of beam loss measurement electronics based on ZYNQ in RCS of CSNS-II 1h 30m

        The beam loss measurement system is an important beam measurement device in the CSNS accelerator, used to measure the beam loss signals along the entire accelerator to monitor the beam status. In CSNS, the beam loss measurement system uses NI PXIe-6358 acquisition card combined with self-developed front-end analog electronics. In the RCS of CSNS-II, a new beam loss electronics based on zynq development is planned to replace the existing electronics for beam loss signal acquisition. The CSNS-II ring beam loss measurement electronics based on zynq consists of independently developed high-voltage output modules, front-end analog boards, digital boards, as well as related driver programs, epics ioc software,etc,realizing functions such as signal acquisition, range control, data processing, epics publishing.

        Speaker: Renjun Yang (Institute of High Energy Physics)
      • 16:00
        Development of bunch-by-bunch beam charge monitor for High Energy Photon Source 1h 30m

        A bunch-by-bunch beam monitor electronics for High Energy Photon Source (HEPS) was designed. The hardware of electronics consists of analog signal acquisition board and digital signal processing board. The software consists of underlying firmware and application software. The sampling frequencyis 500 MHz, and the bandwidth is 1 GHz. The electronics digitizes four analog signals from BPM probe, and ZYNQ chip was used to process the beam data and calculate the charge of each bunch. This system has been used in HEPS booster and will be used in HEPS storage ring.

        Speaker: Zhi Liu (Institute of High Energy Physics)
      • 16:00
        Development status of the fiber length stabilizers for the laser arrival-time measurement 1h 30m

        The Shanghai soft X-ray Free-Electron Laser facility (SXFEL) is a fourth-generation linac-based light source, capable of producing X-ray pulses with duration of tens of femtosecond. The photocathode laser and the seed laser for external seeding FEL therefore have tight requirements for relative arrival time to the machine and electron bunch. To reach required energy and wavelength to drive photocathode, as well as for external seeding FEL, further optical amplification and frequency conversion is needed. the femtosecond-stable pulsed optical reference, which are delivered via fiber length stabilizers. In this paper, we present the development status of the fiber length stabilizers for the laser-arrival time measurement.

        Speaker: Bowei Wu (Shanghai Advanced Research Institute)
      • 16:00
        Diagnostics of beam losses at the Novosibirsk Free Electron Laser 1h 30m

        The article describes the BLM system of the Novosibirsk Free Electron (NovoFEL) microtron. Cherenkov radiation detectors are used to monitor beam losses. When beam of electrons hit the wall of the vacuum chamber, they create a shower of secondary electrons that fly out of the chamber and pass through the detector material, creating Cherenkov radiation in the process. The facility uses two types of Cherenkov detectors: optic fibers and quartz rods. Optic fibers are applied for the localization of the source of beam losses due to short duration of Cherenkov flashes. Quartz rods, on the other hand, measure the average beam loss at their location. In both cases, photomultiplier tubes (PMTs) are used to detect the Cherenkov radiation, and the voltage from the PMTs is digitized using an analog-to-digital converter (ADC) and displayed on a computer screen. This allows operators to monitor beam losses and tune the system accordingly. The article provides an overview of the basic principles of the BLS system of NFEL and describes in detail its operation. It also discusses the choice of detectors and the experience gained from applying diagnostics to tune the NovoFEL.

        Speaker: Lev Fomin (Russian Academy of Sciences)
      • 16:00
        Energy spectrum of an ICP-RF ion source using a spherical electrostatic energy analyzer 1h 30m

        The energy characterization of an RF ion beam, generated by an inductively coupled plasma (ICP) RF ion source, has been conducted using a spherical electrostatic energy analyzer. The RF ion source, operating at an applied frequency of 13.56 MHz and a power level of 300 W, was assessed in both pulse and continuous modes. The ion energy spectrum of the hydrogen beam was meticulously measured under various conditions, with the extraction voltage ranging from 1 to 10 keV. The analysis revealed variations in the energy profiles under different operational conditions, providing insights into the ion source's performance and optimization. These findings contribute to a deeper understanding of RF ion beams for enhancing the design and efficiency of ion sources used in particle accelerators and related technologies. The importance of precise energy spectrum measurements in enhancing the efficiency and functionality of ion sources in advanced beam instrumentation is underscored by this research.

        Speaker: Anna Eydan (Amirkabir University of Technology)
      • 16:00
        Feasibility study of electron beam probe-based longitudinal bunch shape monitor for high-intensity proton beam 1h 30m

        The knowledge of the longitudinal bunch shape is of high interest to accelerator performance optimization and advanced beam application. Attracted by the ability to continuously monitor the beam in real time, there is always a demand for bunch-by-bunch and non-invasive diagnosis. However, such diagnosis is difficult to achieve for proton beam with high intensity and high repetition. Using the principle of electron beam deflection, electron beam probe has the potential of multi-function beam diagnosis. Here, we proposed the concept of real-time longitudinal bunch shape monitor with photocathode DC electron gun. Considering the realistic bunch distribution, we investigated the feasibility of this monitor using particle tracking simulation. The results and analysis of feasibility are reported in this paper.

        Speaker: Heng Wang (Tsinghua University in Beijing)
      • 16:00
        First results with a Base Band Tune (BBQ) measurement system at Solaris 1h 30m

        All CERN circular accelerators are equipped with Base Band Tune (BBQ) measurement systems, based on the direct diode detection technique, allowing to measure the tunes of hadron beams by employing their residual betatron oscillations or very small external excitation. In the framework of the Future Circular Collider (FCC) project, a study was launched to optimise such a system for operation with short electron bunches. A prototype system has been recently installed in Solaris light source. The system has immediately allowed an unprecedented detection of residual betatron oscillations, whose amplitudes, estimated to be in the 100 nm range, are more than two orders of magnitude lower than the smallest beam oscillations used for tune measurements with the Beam Position Monitoring (BPM) system. The residual oscillations allowed reliable continuous tune measurements, which have also revealed spectral content never observed before. This paper provides an overview of the installed BBQ system and describes beam measurement results obtained so far. The aim of the paper is to disseminate new results in the light source community and provide information that may help in building and installing similar systems. It is hoped that wider usage of BBQ systems will help in better understanding the observed spectra of electron beam residual oscillations.

        Speakers: Adriana Wawrzyniak (National Synchrotron Radiation Centre), Marek Gasior (European Organization for Nuclear Research)
      • 16:00
        FPGA algorithm of beam diagnostic devices for fast protection system 1h 30m

        RAON is a multi-purpose accelerator facility that can accelerate various heavy ion beams and exotic rare isotope beam, with a maximum energy of 200 MeV/u for uranium beams. Abnormal behavior or excessive instability of the device may result in damage to the device when an ion beam is irradiated onto the device. A fast protection system has been built, which quickly blocks the beam and prevents damage to devices. Signals generated from LLRF, SSPA, and beam diagnostic devices cause the MPS to block the beam within 50 µs. In beam diagnostic devices, AC current transformer (ACCT), mTCA-based data acquisition (DAQ), and beam position monitor (BPM) electronics are used to inform the MPS of beam transmission status in real time. Post-mortem data is stored on each device, allowing the cause of errors to be identified in the short term before fast protection is activated. This poster shows the measurement details and signal generation algorithm for fast protection in three beam diagnostic electronic circuits produced by the RAON heavy ion accelerator.

        Speaker: Jangwon Kwon (Institute for Basic Science)
      • 16:00
        Laser polarimeter at VEPP-4M collider 1h 30m

        VEPP-4M collider and KEDR detector are going to measure precisely $\Upsilon$(1S) mass and leptonic width.
        In this experiment the electron beam energy is precisely measured using resonant depolarisation tecnhique at "Laser Polarimeter" facility.
        The electron beam polarisation degree is measured using Compton backscattering with accuracy of 5\% in 100 seconds.
        The beam energy is measured during KEDR data acquisition runs every 30~minutes with accuracy of 20~keV.
        In this report the facility design and current status are discussed.

        Speaker: Viacheslav Kaminskiy (Russian Academy of Sciences)
      • 16:00
        Longitudinal bunch diagnostics in the Terahertz domain at TELBE using fast room temperature operable zero-bias Schottky diodes 1h 30m

        Modern accelerator-based light sources rely on short bunches to generate intense photon pulses. To achieve this, the electron bunches from the accelerator need to be compressed longitudinally in a magnetic chicane. A valuable tool for the measurement of the signal in the bunch compressor is the use of broadband EM-detectors covering a spectral range from few 100 GHz up to THz frequencies. With this setup, bunch length variations caused by instabilities in the acceleration process can be measured that in turn also affects the secondary photon beam. In this paper, we demonstrate the pre-commissioning of broadband, room temperature Schottky THz detectors for the diagnosis of compressed short electron bunches at the TELBE facilities at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. Qualitative bunch compression measurements have been carried out to diagnose the beam to optimize the machine setup and provide feedback to the beam-line scientists for optimum machine operation. These detectors are scheduled to be commissioned at free-electron facilities in near-future.

        Speaker: Mr Rahul Yadav (Terahertz Devices and Systems, TU Darmstadt, Germany)
      • 16:00
        longitudinal phase space reconstruction in an electron storage ring 1h 30m

        This paper proposes a longitudinal phase space measurement and reconstruction technology of particle beam in a storage ring. The technology collects and analyzes the beam injection signals by a high-speed oscilloscope, so as to extract the phase and beam length information of the injected beam. The length of a single data collection covers several thousand circles, the measurement accuracy of the phase reaches 0.2ps, and the measurement accuracy of the beam length reaches 1ps. At the same time, we develop a single beam tracking software based on the mbtrack2 software package. The simulation software can record the phase space evolution of the beam after injection under different initial conditions. By matching with the simulation results, we can get various initial parameters of the experimental beam, including the initial phase, the initial beam length, the initial energy deviation, the initial energy dispersion, and the initial injection angle of the beam in the phase space. This technology enables us to understand the kinetic behavior of the particle beam deeply and to monitor and adjust the injection system in real-time. By obtaining the phase space distribution information of the particle beam in real-time, we can find and correct the deviation and instability in the injection system in time, so as to improve the injection efficiency and the quality of the particle beam.

        Speaker: Hongshuang Wang (Shanghai Institute of Applied Physics)
      • 16:00
        Machine Learning Used in BPM Displacement Prediction at HLS II 1h 30m

        Beam orbit stability is a crucial indicator that can be used to evaluate the performance of a synchrotron radiation source. It can be improved through precise orbit measurement with beam position monitors (BPMs) and appropriate orbit feedback. The move-ment of BPMs directly affects the measurement of the beam orbit and indirectly affects the beam orbit through orbit feedback (OFB) system. Two sets of BPM displacement measurement system were estab-lished at Hefei Light Source II (HLS II) storage ring and some machine learning work was carried out on the system.

        Speaker: Chuhan Wang (University of Science and Technology of China)
      • 16:00
        Machine protection system for HIAF 1h 30m

        The High Intensity Heavy-ion Accelerator Facility (HIAF), currently under construction, is a complex machine that couples a Continuous Wave (CW) superconducting ion Linear accelerator (iLinac) with a high-energy synchrotron to produce various stable and radioactive intense beams with high energies. The machine has a versatile operation mode which requires a high flexibility and reliability to the Machine Protection System (MPS). A customized and robust MPS is designed and developed to give the readiness of the machine for operation, to mitigate and analyze faults related to the relative damage potential. To get a high speed and have a high level of reliability, all interlock signal processing is processed on radiation-tolerant Field-Programmable Gate Arrays (FPGA) with triple or dual redundancy, as well as with a fail-safe design. By implementing a multiprocessing platform system-on-chip FPGA, the HIAF MPS can be tightly integrated with other systems to maximize availability pinpoint failures for operations, and give the postmortem analysis. This paper will describe the architecture of the interlocks linking the protection systems, the strategies to manage the complexity, the detailed components, and the interlock logic of the customized HIAF MPS, as well as the test and verification of the prototype.

        Speaker: Yuan Wei (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Measurement and optimization of the beam coupling impedance of a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber 1h 30m

        Dipole magnet vacuum chambers are among the critical and costly components of rapid-cycling accelerator facilities. Alternative approaches to traditional ceramic chambers have been explored for the implementation of fast-ramping dipole-magnet vacuum chambers, including thin-wall metallic beam pipe chambers strengthened with transverse ribs. Here, we report a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber, which is designed for HIAF project to reduce manufacturing difficulty and cost, shorten the production cycle, and improve the quality. Because the beam impedance aspects are highly important for beam stability, comprehensive studies were undertaken to characterize the impedance of the 3D-printed titanium alloy cage inside thin-wall vacuum chamber. The beam-coupling impedance of the new thin-wall vacuum chamber were studied numerically. Strategies for further reducing the beam-coupling impedance were explored. In addition, impedance bench measurements using the “half wavelength” resonant method were conducted to identify the longitudinal and transverse impedance of this thin-wall vacuum chamber prototype experimentally. The simulated and measured results for the impedance were consistent. Furthermore, a campaign for resonance-check measurements on this thin-wall vacuum chamber prototype was launched. This novel thin-wall vacuum chamber structure has been ready for installation in the Booster Ring (BRing).

        Speaker: Guangyu Zhu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Measurement of beam energy characteristics at the LHe-free Nb3Sn demo SRF e-linac 1h 30m

        The demonstration of a 100 mA, 4.6 MeV superconducting radio frequency linear electron accelerator, based on conduction cooling and developed by the Institute of Modern Physics (IMP), aims to validate the feasibility of stable beam commissioning in a liquid helium-free 5-cell-$\beta$opt=0.82 Nb3Sn elliptical cavity, and to offer guidance for subsequent industrial applications. The beam energy characteristics, considered one of the critical parameters, need to be precisely measured.
        Given the high beam energy and the need for a compact, straightforward accelerator layout, we achieved high-precision measurements using only a ordinary dipole, a slit, and a Faraday Cup (FC). This paper presents the online measurement results of beam energy at different cavity voltage and provides a thorough analysis and optimization of the various errors encountered during measurement.

        Speaker: Yimeng Chu (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Measurement of beam phase and energy using BPMs and FCTs at the MEBT section of CSNS H- LINAC 1h 30m

        Accurately measuring the beam phase is critical when determining the ideal RF cavity parameters for beam acceleration. In the past, only Fast Current Transformers (FCTs) were used to measure the beam phase. However, with the upcoming upgrade of the MEBT section for the CSNS-II project, shorted stripline-type BPMs will now be utilized to measure beam position, phase, and energy. LIBERA singlepass electronics are employed to measure the beam position and phase from the BPMs. Pairs of BPMs were used to measure beam phase shift, which can also be used to calculate beam energy. This paper compares beam phase measurement systematically by BPMs and FCT.

        Speaker: Fang Li (Institute of High Energy Physics)
      • 16:00
        Measurement of the H- content in mixed beam from ion source 1h 30m

        H- ion source produces mixed beam of H- and electrons. Usually, a bending magnet is needed to measure the contents of mixed beam. However, bending magnet is generally lacked in H- machine, because bending magnet increases the transport line length, leading to more serve decline of H-. How to measure the H- content in mixed beam without the help of bending magnet is worthy to be studied. In this paper we describe a method to measure the H- content utilizing common devices in low energy beam transport line. This method is mainly based on a solenoid. the H- and electron contents can be obtained by analyzing the change of the beam transmission when sweeping the solenoid current. The experiments were performed.

        Speaker: Baichuan Wang (State Key Laboratory of Intense Pulsed Radiation Simulation and Effect)
      • 16:00
        Measurement of the longitudinal beam size at the Novosibirsk FEL 1h 30m

        The Novosibirsk Free Electron Laser (NovoFEL) facility consists of three free electron lasers (FELs) installed on different tracks of the Energy Recovery Linac (ERL). These FELs share a common acceleration system, which allows for the generation of high average electron currents, typically around 10 mА. This high current facilitates the production of significant average FEL powers, often exceeding 100 watts in the spectral range between THz and mid-infrared wavelengths. Precise measurement of electron beam parameters is crucial for monitoring the performance of the accelerator and fine-tuning its operating modes. The length of the electron bunch is particularly important, as it directly influences the efficiency of laser radiation generation. This study focuses on the dependence of the electron bunch length on the parameters of the radio frequency (RF) and bunching systems for the first and second FELs at NovoFEL. Measurements were conducted using a Cherenkov aerogel radiator in conjunction with a streak camera to accurately determine the electron beam properties. The measurement results, along with a plan for future experiments, are discussed in detail in this publication.

        Speaker: Vladislav Borin (Budker Institute of Nuclear Physics)
      • 16:00
        Methodology for identifying the centre of a solenoid magnet based on the beam dynamics 1h 30m

        The method of varying the strength of the corrector magnet installed upstream and minimising the position variation in diagnostics located downstream is widely used for identifying the centre of the magnetic field produced by a quadrupole magnet. However, in the case of a solenoid magnet, unlike a quadrupole magnet, it is not suitable to apply the variable separation method in the x-y direction since both field components are correlated, and the focusing of the magnetic field occurs in the azimuthal direction. In this presentation, we propose an analytical method for finding the centre of a solenoid magnet and present results validated by simulations.

        Speaker: Dong Hyuck Kim (Gangneung-Wonju National University)
      • 16:00
        New beam loss monitor ionisation chambers engineering 1h 30m

        More than 4000 Beam Loss Monitors (BLM) systems are operating at CERN. About 93% of them are installed in the LHC machine. The Ionisation Chambers (IC) are the part of the system where the lost beam particles ionise nitrogen gas in a chamber with electrodes at high voltage. The resulting current indicates the quantity of the beam loss. In the last 20 years, all BLM ICs were produced in collaboration with external institutes.
        Control of all details of the materials and processes are required to ensure instrument sensitivity and precision across the large series.
        CERN took back this production process in 2022 and much of the specific knowledge of design details and production technology was required to be re-engineered.
        This work presents production specification, design of tooling and test facilities for the first prototypes of a new series to be produced including their test in CERN facilities with beam. The further ramp-up to an industrial process to allow for a production of 1000 units in the years to come is discussed.

        Speaker: Gerhard Schneider (European Organization for Nuclear Research)
      • 16:00
        Online beam phase and energy gain measurement through beam-cavity interaction 1h 30m

        Online beam monitoring is crucial for enhancing the efficiency and availability of high-power accelerator operations. While real-time monitoring of transverse beam parameters is commonly employed in modern accelerators, there is a scarcity of online measurement techniques for longitudinal beam characteristics. We are currently developing an online tool for measuring fundamental longitudinal beam parameters: synchronous phase and energy gain. This endeavor is founded upon a comprehensive understanding of beam-RF cavity interactions, facilitated by advanced hardware platforms, flexible software applications, and computationally intensive algorithms.
        Validation of our measurement methods has been conducted using beam and RF data acquired during the latest beam commissioning at the European Spallation Source (ESS). This validation encompassed both single-cell and multi-cell cavities, affirming the reliability and feasibility of our techniques. Furthermore, comprehensive comparative analyses were performed, aligning results from various measurement methodologies with theoretical calculations, enhancing our understanding of measurement accuracy.
        Our ongoing research aims to provide accelerators with robust and real-time monitoring tools for longitudinal dynamics aspects based on beam and RF cavity interaction, thereby ensuring optimal efficiency and performance in high power accelerator operation.

        Speaker: Lingyun Gong (Institute of Modern Physics, Chinese Academy of Sciences)
      • 16:00
        Phase-temperature stability measurement of various RF coaxial cables 1h 30m

        Phase stable coaxial cables are widely used for the transmission of reference signals, monitoring signals and control signals in accelerator Low-level RF, beam measurement and control systems, especially for high requirements of time/phase stability. The change in ambient temperature will change the electrical length of the coaxial cables leading to the transmission time and signal phase drift, this effect is termed as temperature coefficient of delay (TCD). The TCD curves at room temperature (15~40°C) of various types of coaxial cables commonly used in particle accelerators and other industries are measured. Some cables are tested for the first time. The cables with lowest coefficients are CommScope LDF2-50A, Zhongtian HCAAYZ-50-12 and Trigiant HCTAYZ-50-22, for different cable diameters. According to attenuation, mechanical and TCD parameters, these three cables are chosen in the HEPS phase reference line system and Linac LLRF system respectively.

        Speaker: Dr Xinpeng Ma (IHEP)
      • 16:00
        Recent progress and experimental results of electro-optic bunch arrival time monitor for SHINE 1h 30m

        The timing jitter of electron bunch will affect the temporal and power stability of FEL, as well as the resolution of pump-probe experiment at FELs. In order to improve the time stability of electron bunch by beam feedback, Shanghai high-repetition-rate XFEL and Extreme light facility (SHINE) will employ the Electro-optic Bunch Arrival Time Monitor (EOBAM) to accurately measure the electron bunch arrival time. This paper will introduce design of EOBAM, including the beam pick-up, the electro-optic front-end, the signal detection electronics and the high-level software. Then the latest research progress of the EOBAM for SHINE and the beam experiment for EOBAM prototype based on SXFEL will also be introduced. The experiment results show that the resolution of EOBAM based on the 18 GHz beam pick-up are 5.4 fs@200pC and 8.1fs@100pC.

        Speaker: Xiaoqing Liu (Shanghai Advanced Research Institute)
      • 16:00
        Research and development beamline for the BESSY II booster beamline 1h 30m

        With the refurbishment completed, the optical beamline delivers all the required diagnostics. This paper reports on their status focusing in particular on the R&D beamline branch. The additional branch is equipped with programable mirror and lens position controllers allowing elaborate optical optimisation. This system is used for educational purposes and for improving the source point imaging system through the study of polarisation characteristics. Test systems for an ultra-fast diode and a THz detector are equipped with CMOS cameras and polarisation filters.
        Furthermore the R&D branch complements the existing diagnostics to measure bunch lengths and investigate non-linear beam dynamics.

        Speaker: Pauline Ahmels (Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH)
      • 16:00
        Research and diagnosis of beam parameters in the SKIF linear accelerator 1h 30m

        The fourth-generation synchrotron light source Siberian Ring Photon Source (SKIF), located in Novosibirsk, Russia, underwent the tuning of its linear accelerator segment successfully. By deploying a designed beam diagnostic system, crucial parameters of the beam including beam transverse and longitudinal dimensions, energy spread, emittance, and current, were accurately measured. To achieve these measurements, the system was equipped with several fluorescent screens, Cherenkov radiation detectors, a dipole energy spectrometer, and a Faraday cup. This paper elaborates on the design, mode of operation, and practical applications of these diagnostic devices during the accelerator's tuning process. Further, potential areas of optimization for these diagnostic methods are explored to provide feasible directions for enhancing the performance of the linear accelerator. These precise diagnostic tools have been pivotal in the successful tuning of the SKIF linear accelerator. The results thus gathered will form a significant reference point for the development and refinement of similar accelerators in the future.

        Speaker: Dr Xiaochao Ma (Budker Institute of Nuclear Physics)
      • 16:00
        SIRIUS fast beam orbit interlock system 1h 30m

        Insertion devices (IDs) are currently being installed at the SIRIUS storage ring to provide photon beams for upcoming high-brilliance beamlines. A fast orbit distortion detection system is imperative to safeguard critical vacuum chambers located near the straight sections of the IDs. In November 2023, an in-house Delta undulator was successfully installed, and a fast orbit interlock protection system has been in place, utilizing BPMs and the timing system's infrastructure. A dedicated position and angle calculation is implemented in FPGA and operates at a 6 kHz rate in the BPM processing electronics. A timing receiver board at the BPM uTCA crate acts as a bridge between orbit distortion detection and the timing system’s event generator (EVG), which sends an interlock signal to the LLRF controller. The main purposes of this work are to provide details about a new full-duplex timing network implementation, to discuss the main requirements of the orbit interlock, and to present measured performance results. Additionally, in pursuit of enhancing system reliability, post-mortem analysis and ongoing implementation proposals will also be presented.

        Speaker: Fernando Henrique Cardoso (Brazilian Synchrotron Light Laboratory)
      • 16:00
        Specialized Optical Pulse Picker for Beam Diagnostics in Storage Ring 1h 30m

        The non-uniformity, longitudinal oscillations, and space charge effects in a multi-bunch filled electron stor-age ring can lead to significant deviations in the meas-urement of longitudinal beam parameters. Selecting a single bunch for measurement can effectively improve the measurement accuracy of longitudinal beam parame-ter, under normal multi-bunch operation mode. This pa-per introduces an optical pulse selection system based on an RTP crystal Pockels cell, which is controlled by fast electronics and high-voltage electronics, to study the complex longitudinal beam dynamics. By adjusting the driving voltage frequency and trigger delay of the high-voltage driver, precise selection of single pulses in a multi-bunch filling mode can be achieved. Offline cali-bration experiments have verified the potential feasibility of selecting specific bunches or bunch trains within the multi-bunch operation, which is of great significance for diagnosing longitudinal characteristics and instabilities of the beam in electron storage rings.

        Speaker: MingDong Ma (University of Science and Technology of China)
      • 16:00
        Status and performance of LumiBelle2 in the 2024 beam operation of SuperKEKB 1h 30m

        LumiBelle2 is a fast luminosity monitoring system designed to do fast luminosity feedback and machine tuning and beam parameters studies for SuperKEKB. It uses sCVD diamond detectors placed in both the electron and positron rings to measure the Bhabha scattering process at vanishing photon scattering angle. Two types of online luminosity signals are provided, Train-Integrated-Luminosity signals at 1 kHz as input to the dithering feedback system used to maintain optimum overlap between the colliding beams in horizontal plane, and Bunch-Integrated-Luminosity signals at about 1 Hz to check for variations along the bunch trains. Vertical beam sizes and offsets can also be determined from collision scanning. This paper will describe the design of LumiBelle2 and report on its performance in the 2024 beam operation of SuperKEKB.

        Speaker: Meng Li (Chinese Academy of Sciences)
      • 16:00
        Study of gas bremsstrahlung for 3 GeV electron storage ring using FLUKA Monte Carlo code 1h 30m

        The Iranian Light Source Facility, ILSF, is under design as a 3 GeV synchrotron light source. The storage ring of ILSF with a 528 m circumference and NEG-coated vacuum chamber is used to achieve the desired vacuum level. In this paper, the monitoring system for gas bremsstrahlung radiation from the storage ring is studied. Gas bremsstrahlung is produced when the stored electron beam interacts with residual gas molecules in a storage ring vacuum chamber. The simplified geometry of the gas bremsstrahlung detector consists of a scintillator, an aluminum holder, and a lead sheet. This geometry is used in the FLUKA simulation package to study gas bremsstrahlung production in SR and its interaction with the detector.

        Speaker: Samira Mohammadi Alamouti (Iranian Light Source Facility)
      • 16:00
        Study of high transmittance ionisation chambers 1h 30m

        With the development of radiotherapy,the need for high doses became strong.However, existing ion chambers are either more absorbent of X-rays in terms of material or are non-sealed, that subject to environmental influences and have a short lifecycle. Now we designed a new ion chamber,which have high dose pass-rate,sealed and long lifecycle under radiation environments.The dose pass-rate improves a lot than the latest one ,keeps ultra high vacuum as very low leakage rate and 10 years lifecycle. Another important point is this kind of ion chamber have very simple assembly process and low cost.After our beam test, it performed very well with various test environments as Reproducibility of the dose response, Proportionality of the dose response, Stability of the dose response and so on.

        Speaker: Mr Zhiquan Zhang (Elekta Beijing Medical Systems Co.Ltd.)
      • 16:00
        Terahertz diagnoses bunch-to-bunch spacing for ultrafast electron bunch trains 1h 30m

        Ultrafast micro-bunched electron beams have broad applications, including wakefield-based acceleration and coherent Terahertz sources, where precise diagnosis of individual bunch-to-bunch spacings is critical. However, high-precision direct measurements of these spacings remain challenging. This paper introduces a novel method capable of measuring these spacings with femtosecond temporal resolution using a THz-driven resonator. Simulations on a 3 MeV electron bunch train demonstrate a temporal resolution better than 10 fs for the bunch-to-bunch spacings. This method facilitates in-depth investigation of the longitudinal characteristics of the bunch train, promising significant advancement in narrow-band Terahertz sources and compact accelerators.

        Speaker: Yang Xu (Huazhong University of Science and Technology)
      • 16:00
        The analysis of electron and ion movement inside the Faraday cup and error generation for finding the best biasing configuration 1h 30m

        In this work, we analyze the movement of the electrons and ions inside a Faraday cup with different biasing of the collector cup, drift tube and suppressor ring. The possible error due to wrong biasing is also investigated. The particle pass is tracked in different biasing configurations. Also, the effect of stray electrons and ions, which are generated due to gas ionization along the beam pass, is studied. Through the analysis, we found the best biasing for the proposed configurations of the Faraday cup.

        Speaker: Amin Masoumzadeh (Amirkabir University of Technology)
      • 16:00
        The beam orbit reconstruction in the linac of CSNS 1h 30m

        In the high current hadron machine, it is essential to reduce the beam loss along the machine for machine maintenance and safety reasons. The linac of Chinese Spallation Neutron Source (CSNS) delivery negative hydrogen bunches with power of 5kW to the RCS which increase the power to 100 kW. In the following several years, the power of the linac beam will be increased to from 5 kW to 100 kW, therefor it is important to deal the beam loss more carefully. In this paper, we present the reconstruction of the beam orbit along the linac using beam tracking software with the input data measured with BPMs. This kind of reconstruction is expected to provide suggestions for the future machine tuning. The requirements for the BPMs are also presented in this paper.

        Speaker: Yanliang Han (Institute of High Energy Physics)
      • 16:00
        The bunch length monitor based on CSR in SXFEL 1h 30m

        Monitoring the beam length and maintaining stability during operation is crucial for Free Electron Laser (FEL) user facilities. A monitor based on Coherent Synchrotron Radiation (CSR) is an ideal candidate, and it has been successfully developed at the Shanghai X-ray Free Electron Laser (SXFEL). This article presents the basic principles, system configuration, and experimental results. The results show that the monitor is capable of measuring the bunch length within a range of 0.6 ps to 1.4 ps, achieving a precision better than 10%.

        Speaker: Lianfa Hua (Shanghai Synchrotron Radiation Facility)
      • 16:00
        The status of beam loss diagnostics system for the SKIF synchrotron light source 1h 30m

        The Siberian Ring Photon Source (SKIF) is a fourth-generation synchrotron light source that operates at a beam energy of 3 GeV. In order to ensure the reliable operation of the accelerator, a beam loss diagnostics system will be implemented. For the linear accelerator, linac-to-booster and booster-to-storage ring transfer lines, fiber-based Cherenkov beam loss sensors will be used. Multi-mode quartz fibers and photo multiplier tubes (PMTs) will provide spatial resolution for this diagnostic system at a level of about 1 meter. The storage ring will be equipped with 128 scintillation-based detectors with acquisition electronics that are placed around the circumference of the ring. These detectors will be able to measure beam losses both during beam injection and during regular SKIF operations for SR users. Since SKIF will operate in different working modes, the BLMs system will require high sensitivity, a large dynamic range, and sophisticated electronics. The paper describes the design of both types of beam loss monitors (BLMs) and the choice of their positioning around the storage ring. It also discusses the final design of the acquisition electronics, the tests of the BLMs and the current status of diagnostics.

        Speaker: Oleg Meshkov (Budker Institute of Nuclear Physics)
      • 16:00
        The synchronization and timing system updating at CTFEL facility 1h 30m

        Chinese Academy of Engineering Physics terahertz free electron laser facility (CTFEL) is a superconducting linac-based user facility. It provides laser pulses with frequencies from 0.1 THz to 4.2 THz. CTFEL works in pulsed mode with a repetition of 10 Hz where up to about 54000 bunches at a bunch spacing of 18.5 ns are accelerated in one macro-pulse. To satisfy the high-precision synchronization requirement from user experiments, the synchronization system based on coaxial lines is updated to a continuous laser carrier and Michelson interferometer-based system. The timing system is updated to the event system.

        Speaker: Shuai Ma (China Academy of Engineering Physics, Institute of Applied electronics)
      • 16:00
        Transverse and longitudinal optical beam diagnostics for the BESSY II booster 1h 30m

        This paper describes the optical beam diagnostics available at the BESSY II booster synchrotron.
        For the first time, diagnostics are established to investigate the distribution of the electron beam in all three dimension.
        A permanent installation of a source-point imaging system aided by a telescope optic depicts the transverse properties of the electron beam.
        Additionally, the bunch length is measured using a streak camera with a resolution in the picosecond range.
        Both systems can work in parallel and are able to observe the non-equilibrium beam dynamics over the entire booster ramp.

        Speaker: Marco Marongiu (Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH)
      • 16:00
        Using transimpedance amplifiers for current measurements of long beam pulses 1h 30m

        CERN H- Linac 4 (L4) and ion Linac 3 (L3) operate with millisecond beam pulses, which pose a challenge for beam current measurements based on Fast Beam Current Transformers (FBCTs). In the past the low cut-off frequencies of the FBCTs were actively lowered using a combination of transimpedance (TI) amplifiers and integrating amplifiers. Unfortunately, in many locations such amplifiers were sensitive to interference from neighbouring power systems. The situation was particularly difficult in L3, where in addition to long beam pulses, the challenge was also small beam currents. The interference problems had been addressed for years with limited success and finally it was decided that the whole FBCT front-end electronics should be renovated, with the main objective being to improve the immunity to interference. This paper describes the evolution of the FBCT front-end electronics and installations, which has finally allowed reliable beam current measurements, whose examples are provided. The key improvement was the use of small TI amplifiers directly connected to the FBCTs, which in addition simplified installations in both linacs. The TI amplifiers provide an active low impedance load to the FBCTs, extending their time constants by some two orders of magnitude, as compared to operation with a 50 Ohm load. Challenges of the TI amplifier implementation are described, along with particularities of their beam commissioning.

        Speaker: Marek Gasior (European Organization for Nuclear Research)
      • 16:00
        Wide range and high precision grid-cathode modulation of beam current for High Energy Photon Source electron gun 1h 30m

        High Energy Photon Source (HEPS) is the fourth-generation light source under construction in China. The electron gun system is the origin of beam acceleration. This article introduces the wide range and high precision grid-cathode modulation of beam current for the HEPS electron gun system. Its grid-bias voltage adjustment is as fine as 0.01V. Cathode filament current and voltage ripple<0.1%. Its grid-bias voltage adjustment accuracy reaches 0.01V. The cathode filament current and voltage ripple <0.1%. The beam test results show that the beam current amplitude stabilization of 2.37% (small current),0.13% (high current), beam current time jitter 12.459ps. Meets physical requirements for a wide range of injector from 2.8nC to 7nC.

        Speaker: Jingdong Liu (Chinese Academy of Sciences)
    • 17:30 21:00
      Conference Banquet 3h 30m
    • 09:00 09:50
      FRA: Transverse Profile and Emittance Monitors: FRAT (Tutorial) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Kenichirou Satou (High Energy Accelerator Research Organization)
      • 09:00
        Secondary, thermionic and delta electron emission from thin targets 50m

        Thin objects in the form of wires, foils or strips are often used as targets in various instruments that measure beam parameters or for other purposes. They usually cause only small beam perturbations and suffer from relatively low temperature increases. The beam induces the emission of secondary electrons, which are usually the source of the measured signal. In high brightness beams, the targets can reach high temperatures, which lead to thermionic current emission. Also, a small amount of delta electrons is emitted, which has a negligible effect on the emitted current but affects the beam heating. These three types of electrons have different properties and influence the measured signal as well as the temperature evolution of the target. This paper discusses how the signal is generated by the escaping electrons, how bunch field affects this signal and how the target temperature depends on the electron emission.

        Speaker: Mariusz Sapinski (Paul Scherrer Institut)
    • 09:50 10:10
      FRA: Transverse Profile and Emittance Monitors: FRAC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Kenichirou Satou (High Energy Accelerator Research Organization)
      • 09:50
        BGC monitor: first year of operation at the LHC 20m

        The Beam Gas Curtain (BGC) monitor was installed in the beam one of the Large Hadron Collider (LHC) during Long Shutdown 2 (LS2) and the Year-End Technical Stop (YETS) 2022. The monitor detects the fluorescence signal generated due to the interaction between the charged particle beams in the LHC and the neon atoms in the supersonic gas curtain. This provides 2D images of the primary beam.
        In the 2023 run, it was demonstrated that transverse beam profile measurement for both, proton beam and lead ion beams in the LHC is possible across injection, energy ramp-up and top energy operation. The BGC has shown the potential to be an operational instrument and efforts to integrate the monitor into the main machine control system are being undertaken. In this contribution, we will present measurement results and discuss the operational experience including observed gas loads to the LHC, observed impact on beam losses and demonstrated resolution of the monitor. Finally, we will also discuss future plans for the continued optimization of this monitor and the installation of a second monitor into beam two.

        Speaker: Hao Zhang (Cockcroft Institute)
    • 10:10 10:50
      Morning Coffee Break 40m
    • 10:50 11:20
      FRB: Beam Loss Monitors and Machine Protection/Beam Charge and Current Monitors: FRBI (Invited Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Thibaut Lefevre (European Organization for Nuclear Research)
      • 10:50
        Development of ultra-fast diamond-sensor based systems for advanced accelerator diagnostics 30m

        The Advanced Accelerator Diagnostics collabora-tion has been developing diamond-sensor based high bandwidth position-sensitive diagnostics for applica-tion at next generation XFELs and other accelerator facilities. A pass-through diagnostic with 50 MHz rate capability has demonstrated pulse-by-pulse position sensitivity of 1% of delivered beam width. Progress has been made in upgrading this diagnostic approach to multi-GHz operation, involving an integrated detec-tion system design making use of a compact signal path and proximate high-bandwidth readout ASIC. Preliminary results are presented on the performance of both the signal path and ASIC. Possible additional applications, including precision event timing and plasma ignition diagnosis, are introduced.

        Speaker: Bruce Schumm (Santa Cruz Institute for Particle Physics)
    • 11:20 12:00
      FRB: Beam Loss Monitors and Machine Protection/Beam Charge and Current Monitors: FRBC (Contributed Oral) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      Convener: Thibaut Lefevre (European Organization for Nuclear Research)
      • 11:20
        A systematic investigation of beam losses and position reconstruction techniques measured with a novel oBLM at CLEAR 20m

        Optical Beam Loss Monitors (oBLMs) allow for cost-efficient and spatially continuous measurements of beam losses at accelerator facilities. A standard oBLM consists of several tens of meters of optical fibre aligned parallel to the beamline, coupled to photosensors at either or both ends. Using the timing information from loss signals, the loss positions can be reconstructed. This contribution presents a novel oBLM system recently deployed at the CERN Linear Electron Accelerator for Research (CLEAR). Multiple methods of extracting timing and position information from measured waveforms are investigated, and the potential impact of varying beam parameters such as bunch charge or number is analysed. This work has resulted in the development of a GUI to aid operations by visualizing the beam losses and their positions in real time.

        Speaker: Montague King (European Organization for Nuclear Research)
      • 11:40
        SPS fast spill monitor developments 20m

        The North Area facility (NA) receives the 400 GeV proton beam through a slow extraction process at the CERN Super Proton Synchrotron (SPS). To improve the SPS spill quality, it is crucial to monitor the spill intensity from the nA up to the µA range with a bandwidth extending from a few Hz up to several GHz along the extraction line. The most promising measurement options for this purpose are the Optical Transition Radiation-PhotoMultiplier (OTR-PMT) and the Cherenkov proton Flux Monitor (CpFM). This document presents recent improvements of both devices based on the operational experience gathered throughout the 2023 Run. It includes a detailed analysis and discussion of the present performance, comparing the capabilities of each instrument. Additionally, future ideas for multi-GHz detectors, particularly for the SHIP collaboration, are also outlined.

        Speaker: Sara Benitez Berrocal (European Organization for Nuclear Research)
    • 12:00 12:20
      FRB: Beam Loss Monitors and Machine Protection/Beam Charge and Current Monitors: FRCL (Closing Remarks) China Hall 2 (Auditorium)

      China Hall 2

      Auditorium

      • 12:00
        IBIC2025 Report 10m

        This talk will show the infomation about IBIC2025.

        Speaker: Prof. Carsten Welsch (The University of Liverpool)
      • 12:10
        Concluding Remarks and Closing 10m

        This talk will show summary of IBIC2024.

        Speaker: Junhui Yue (Institute of High Energy Physics)
    • 12:20 13:00
      Simple Lunch Box 40m
    • 13:00 18:00
      Facility Tour 5h