Description
The 30 MeV section of the Advanced Rare Isotope Laboratory (ARIEL) electron linear accelerator (e-Linac), a 1.3 GHz superconducting SRF system, currently includes the injector cryomodule (EINJ), housing a single nine-cell cavity, and the first accelerator cryomodule (EACA), configured with two cavities. This paper reports recent progress of high-power RF system operation. In 2025, the system achieved stable continuous operation for three consecutive days with a 30 MeV, 1 mA beam, reaching a reliability of approximately 97.9%. EACA, operating in vector sum mode, has demonstrated stable operation for up to eight days.