9–13 Sept 2024
Wanda Realm Beijing
Asia/Shanghai timezone
Registration Deadline: August 9 (23:59 UTC+8), 2024; Paper Submission Deadline: September 5 (23:59 UTC+8), 2024

Beam diagnostics systems for the LINAC of LUTF

TUP69
10 Sept 2024, 16:00
1h 30m
China Hall 3

China Hall 3

Poster Presentation MC9: Overview and Commissioning TUP: Tuesday Poster Session

Speaker

Ming Meng (Chongqing University)

Description

" Laboratory for Ultrafast Transient Facility" is organically composed of two major categories of core parts: one is a Ultrafast Transient electron microscope cluster; the other is a Ultrafast Transient synchrotron radiation device that provides ultraviolet to X-rays. The first stage of synchrotron radiation device includes a 0.5 GeV linear accelerator as full energy injector, a high-current storage ring, and a beam line. For the construction of the linear accelerator beam diagnostics system, the main focus is on the reliability and maintainability of the system. The system mainly includes beam position measurement system , bunch charge measurement system and beam profile measurement system; the article will mainly introduce the composition and design of these systems.

I have read and accept the Privacy Policy Statement Yes

Primary author

Ming Meng (Chongqing University)

Co-authors

Bocheng Jiang (Chongqing University) ZhongQuan Li (Chongqing University) DongHui Zhu (Chongqing University) Xi Wu (Chongqing University) Junqiang Zhang (Chongqing University) Yao Zhang (Chongqing University) Lei Yang (Chongqing University) Tao Lei (Chongqing University) XiaoDong Yang (Chongqing University) Yao Yang (Chongqing University)

Presentation materials

There are no materials yet.