Development of Readout System for Target Multi-Wire Scanner Beam Profile Measurement of CSNS-II

THPT21
Oct 23, 2025, 3:30 PM
2h
third floor (conference center)

third floor

conference center

Poster Presentation WGE: Beam Instrumentation, beam Interaction and AI technology THPT poster session

Speaker

Zhijun Lu (Institute of High Energy Physics)

Description

Target Multi-Wire Scanner is a beam diagnostics device in the CSNS-II accelerator, designed to measure the pre-target beam profile. This paper details the hardware composition, software architecture, and beam-target interaction test results of the CSNS-II front-end multi-wire scanner readout system. In contrast to the CSNS predecessor, the upgraded system employs a hybrid software architecture combining a LabVIEW-based signal acquisition platform with a standardized EPICS Input/Output Controller (IOC) developed in C. The LabVIEW software handles signal acquisition and front-end electronics control, while processed data is transmitted to the EPICS IOC for standardized data publishing. This architecture enhances system stability and ensures reliable EPICS-based data interaction, demonstrating an optimized instrumentation framework for high-precision beam diagnostics in high-power proton accelerators.

I have read and accept the Privacy Policy Statement Yes

Author

Zhihong Xu (Institute of High Energy Physics)

Co-authors

Renjun Yang (Institute of High Energy Physics) Ruiyang Qiu (Institute of High Energy Physics) Fang Li (Institute of High Energy Physics) Lei Zeng (Institute of High Energy Physics) Weiling Huang (Institute of High Energy Physics) Mengyu Liu (Chinese Academy of Sciences) Zhijun Lu (Institute of High Energy Physics)

Presentation materials

There are no materials yet.