The Relativistic Heavy Ion Collider (RHIC) Run 23 program consisted of collisions of 100 GeV gold beams at two collision points for the first time since 2016; the sPHENIX collaboration used the beam to commission their new detector systems while STAR took physics data. Completion of sPHENIX construction pushed the start of the run to May, forcing the collider complex to operate over the summer months and incurring lower than normal availability due to heat and power dip related problems. Issues with dynamic pressure rise during acceleration through transition resulted in a slower ramp up of intensity compared to prior years. Finally, a failure of a warm-to-cold current lead interface in the valve box for the Main Magnet power supply forced the run to end. This paper will discuss the progress made by each experiment and the failure mode, repair and mitigation efforts in preparation for Run 24.