17–22 May 2026
C.I.D
Europe/Zurich timezone

Impedance and magnet field analysis of the septum in Hefei Advanced Light Facility

TUP7652
19 May 2026, 16:00
2h
C.I.D

C.I.D

Deauville, France
Poster Presentation MC7.T09: Normal Conducting Magnets Poster session

Speaker

Dr Wenbin Song (University of Science and Technology of China)

Description

An eddy-current design is used for the septum in HALF (Hefei Advanced Light Facility), with the whole cores located in a vacuum chamber. The stored beam passes through a copper vacuum pipe which set in the vacuum chamber. Two types of connections between the copper pipe and the flanges at both ends of the chamber were considered. The impedance calculations were done, and the wake-field, heat have also been analyzed. A flexible connection using a beryllium bronze casing was finally selected.

In which format do you inted to submit your paper? Word

Author

Dr Wenbin Song (University of Science and Technology of China)

Presentation materials