17–22 May 2026
C.I.D
Europe/Zurich timezone

MAGNETIC CENTER MEASUREMENT AND FIDUCIALIZATION METHOD FOR HALF

TUP7717
19 May 2026, 16:00
2h
C.I.D

C.I.D

Deauville, France
Poster Presentation MC7.T17: Technology: Alignment and Survey Poster session

Speaker

BaoHou Liu (University of Science and Technology of China)

Description

To meet the stringent alignment requirements for accelerator magnets in the Hefei Advanced Light Facility (HALF),
accurate fiducialization of the magnetic center is essential.
This paper presents a high-precision and efficient fiducialization method developed for HALF, based on a single stretched
wire bench integrated with a precision surface plate. The
system enables precise determination of the relative coordinates between the magnetic center and the magnet fiducials.
Experimental results demonstrate that the overall fiducialization accuracy is better than 10 µm, thereby satisfying the
rigorous demands of magnetic center fiducialization for the
HALF project.

In which format do you inted to submit your paper? LaTeX
Preprint marking on your proceeding paper I do not intend to submit a paper associated with this contribution.
I no longer wish to present this contribution, please withdraw it. Keep my contribution

Author

BaoHou Liu (University of Science and Technology of China)

Co-authors

Prof. CHAO ZHANG (University of Science and Technology of China) Hong-liang Xu (University of Science and Technology of China) Tian Hao Sun (University of Science and Technology of China) Yao Lu (University of Science and Technology of China) Zhiliang Ren (University of Science and Technology of China)

Presentation materials

There are no materials yet.