The Institute for Applied Physics (IAP) installed a permanent test setup for up to \SI{60}{\kilo\watt} of RF power in cw mode for conditioning. The goal is to establish a time efficient test procedure for the future MYRRHA CH-cavities. Three test stands were designed to accommodate up to three cavities simultaneously.
All stations are curently tested via the \SI{175}{\mega\hertz} MAX RFQ prototype at IAP with the new test setup. Vacuum, Low-level-, and high-power measurements have been successfully performed.