This control system had been designed for the injection and extraction system of Shanghai Advanced Proton Therapy(SAPT). Interface of the SPELLMAN 100 kV high voltage power supply for septum magnets and Capacitor Charing Power Supply(CCPS) of the pulser for bumper magnets are including in the control design based on Programble Logic Contrllor (PLC) s7-1200. The control system realizes the precise digital setting and states reading of the high power supplys and focuses on the remote anti-interference information transmission through the designing of a multi-channel frequency and voltage converter.The system is already stable and reliable working for years in the proton accelerator facility hall.