High-reliability and high-performance machine protection system for a demanding electron linac

THPG57
23 May 2024, 16:00
2h
Bluegrass (MCC Exhibit Hall A)

Bluegrass

MCC Exhibit Hall A

Poster Presentation MC6.T23 Machine Protection Thursday Poster Session

Speaker

Rok Hrovatin (Cosylab)

Description

LightHouse was a project utilizing a 3 MW electron linac to produce medical isotopes, requiring a very fast and reliable machine protection system to protect key accelerator components. RI Research Instruments GmbH designed the linac and conducted the risk analysis. This led to specifications to which Cosylab engineered a machine protection system (MPS). The MPS exhibits rapid responsiveness, with short reaction times on the order of 350 nanoseconds, while actively monitoring and reacting to approximately 700 inputs from crucial accelerator components. To enhance reliability and upgradeability, an FPGA solution based on the National Instruments platform was implemented. Additionally, the project envisions the integration of high availability storage and tertiary subsystems, with the overarching goal of achieving elevated uptime and ensuring the trustworthiness of all device elements.

Region represented Europe
Paper preparation format Word

Primary author

Rok Hrovatin (Cosylab)

Co-authors

Benjamin Ocepek (Cosylab) Marc Grewe (RI Research Instruments GmbH)

Presentation materials