Modification of TPS arc-cell vacuum system for installation of EPU66

TUPR61
21 May 2024, 16:00
2h
Rock 'n Roll (MCC Exhibit Hall A)

Rock 'n Roll

MCC Exhibit Hall A

Poster Presentation MC7.T14 Vacuum Technology Tuesday Poster Session

Speaker

Che-Kai Chan (National Synchrotron Radiation Research Center)

Description

Modification of an arc-cell vacuum system (length 14 m) for the cell SR18 in the TPS storage ring is described, which includes (a) replacement of a new bending chamber (B1) with an increased vertical aperture from 9 to 18 mm to prevent the B1 chamber from being exposed to synchronous radiation from the upstream elliptically polarized undulator (EPU), and (b) incensement of three pairs of flanges to separate the old arc-cell vacuum system into four subsystems (S3, B1, S4, B2). In this paper, we will report the manufacturing processes, measurement data and vacuum tests of these vacuum chambers.

Region represented Asia
Paper preparation format Word

Primary author

Bo-Ying Chen (National Synchrotron Radiation Research Center)

Co-authors

Che-Kai Chan (National Synchrotron Radiation Research Center) Chia-Mu Cheng (National Synchrotron Radiation Research Center) Chin Shueh (National Synchrotron Radiation Research Center) Chin-Chun Chang (National Synchrotron Radiation Research Center) Yi-Chen Yang (National Synchrotron Radiation Research Center)