Speaker
Che-Kai Chan
(National Synchrotron Radiation Research Center)
Description
Modification of an arc-cell vacuum system (length 14 m) for the cell SR18 in the TPS storage ring is described, which includes (a) replacement of a new bending chamber (B1) with an increased vertical aperture from 9 to 18 mm to prevent the B1 chamber from being exposed to synchronous radiation from the upstream elliptically polarized undulator (EPU), and (b) incensement of three pairs of flanges to separate the old arc-cell vacuum system into four subsystems (S3, B1, S4, B2). In this paper, we will report the manufacturing processes, measurement data and vacuum tests of these vacuum chambers.
Region represented | Asia |
---|---|
Paper preparation format | Word |
Primary author
Bo-Ying Chen
(National Synchrotron Radiation Research Center)
Co-authors
Che-Kai Chan
(National Synchrotron Radiation Research Center)
Chia-Mu Cheng
(National Synchrotron Radiation Research Center)
Chin Shueh
(National Synchrotron Radiation Research Center)
Chin-Chun Chang
(National Synchrotron Radiation Research Center)
Jing-Hao Kang
(National Synchrotron Radiation Research Center)
Wei-Yang Lai
(National Synchrotron Radiation Research Center)
Yi-Chen Yang
(National Synchrotron Radiation Research Center)