The 1-MeV LCLS-II electron source including CW RF gun and buncher was successfully commissioned 2018-2020. Since then, a few upgrades has been implemented. Full scale of LCLS-II injector including the upgraded 1-MeV electron source, one standard 100-MeV Cryomodule, essential diagnostics for beam performance characterizations is being commissioned since late March 2022. This report will present technical progresses and challenges of the injector commissioning and measurements of e-beam performance as well as dark current.