Speaker
Description
Nb$_3$Sn SRF cavities have the potential to reduce operating and capital costs for SRF accelerators. A first-of-its-kind Nb$_3$Sn 2-cavity CEBAF-type cryomodule has been assembled and tested. The cryomodule contains two 5-cell cavities: one coated and qualified by the team at Jefferson Lab and the other by the team at Fermilab. The cryomodule, assembled and tested at Jefferson Lab, achieved 10 MV accelerating voltage. This talk highlights steps during this development, including cavity preparation and qualification, mitigations to avoid cavity performance degradation during string and cryomodule assembly, and cryomodule testing.
Funding Agency
This manuscript has been authored by FermiForward Discovery Group, LLC under Contract No. 89243024CSC000002 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics.
I have read and accept the Privacy Policy Statement | Yes |
---|---|
Please consider my poster for contributed oral presentation | No |
Would you like to submit this poster in student poster session on Sunday (August 10th) | No |