Speaker
Aamna Khan
(Brookhaven National Laboratory)
Description
In this study, we present a comparative analysis of passive higher-harmonic cavity (HHC) simulations with beam loading compensation using the particle tracking codes ELEGANT and SPACE. By cross-verifying results from both codes, we assess their accuracy in modeling beam dynamics under passive HHC operation for different filling patterns. Our findings demonstrate consistent outcomes between ELEGANT and SPACE, validating their effectiveness in simulating passive HHC systems with beam loading compensation. This work provides valuable insights for optimizing beam stability and performance in storage rings with HHCs.
I have read and accept the Privacy Policy Statement | Yes |
---|---|
Please consider my poster for contributed oral presentation | Yes |
Would you like to submit this poster in student poster session on Sunday (August 10th) | No |
Author
Aamna Khan
(Brookhaven National Laboratory)
Co-authors
Gabriele Bassi
(Brookhaven National Laboratory)
Victor Smaluk
(Brookhaven National Laboratory)