Speaker
Cristian Maccarrone
(European Synchrotron Radiation Facility)
Description
In this contribution we present a compact differential pumping chamber with apertures ≥ 500 μm. It allows windowless operation for in-air sample environments as well as to connect low-quality in-vacuum sample environments to the beamline UHV vacuum section. To simplify the design, it was decided not to integrate a positioning system and to rely on machining tolerances. In the end, the assembly consists of just 7 parts: 1 main aluminium body, 3 threaded cylinders with apertures and 3 covers with link to pumping units to be assembled with viton seals. The overall footprint is restricted to 368mm on the beam axis.
Author
Cristian Maccarrone
(European Synchrotron Radiation Facility)
Co-authors
Karim Lhoste
(European Synchrotron Radiation Facility)
Anne-Lise Buisson
(European Synchrotron Radiation Facility)
Marco Cammarata
(European Synchrotron Radiation Facility)