Speaker
Suyin Grass Wang
(Argonne National Laboratory)
Description
The Direct Current Current Transformer (DCCT) in the Advanced Photon Source (APS) Storage Ring is used to measure the storage ring current. This measurement is digitized using an HP3458A Multimeter and synchronized with beam injection through the Micro-Research Finland (MRF) event system. This paper describes the setup and timing of the control system for the DCCT, highlighting its integration and functionality within the APS infrastructure.
Funding Agency
The work is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11357
Author
Suyin Grass Wang
(Argonne National Laboratory)
Co-authors
Thomas Fors
(Argonne National Laboratory)
Ran Hong
(Argonne National Laboratory)
Robert Keane
(Argonne National Laboratory)
Weixing Cheng
(Argonne National Laboratory)
Guobao Shen
(Argonne National Laboratory)