25–30 Aug 2024
Hilton Chicago
America/Chicago timezone

LCLS-II longitudinal beam diagnostics based on a short S-band deflector

THPB070
29 Aug 2024, 16:00
2h
Boulevard (Hilton Chicago)

Boulevard

Hilton Chicago

720 South Michigan Ave Chicago, IL 60605 USA
Poster Presentation MC4.1 Beam diagnostics Thursday Poster Session

Speaker

Valery Dolgashev (SLAC National Accelerator Laboratory)

Description

We designed, built and commissioned a beam diagnostic system based on a short S-band defector and a commercial klystron transmitter. A two feet long transverse-horizontally deflecting S-band rf structure (STCAV2) is installed the LCLS-II post-laser-heater diagnostic beamline at 100 MeV electron beam energy to measure the absolute electron bunch length and to allow time-resolved beam quality measurements such as vertical slide emittance and slice energy spread. The deflector is designed to produce 0.48 MeV peak kick at 300 kW of input power. The klystron transmitter, which uses a commercial solid-state modulator, is installed in the klystron gallery at the grade level. The low-level RF system is based on ATCA and developed in-house. We will report on the overall performance of the project, which was successfully completed, on May 31, 2024.

Author

Valery Dolgashev (SLAC National Accelerator Laboratory)

Co-authors

Axel Brachmann (SLAC National Accelerator Laboratory) Ernest Williams (SLAC National Accelerator Laboratory) Eugene Kraft (SLAC National Accelerator Laboratory) Kathleen Ratcliffe (SLAC National Accelerator Laboratory) Michael Kosovsky (SLAC National Accelerator Laboratory)