22–26 Aug 2022
Trieste Convention Centre
Europe/Zurich timezone

Characterisation of a Diamond Channel Cut Monochromator Designed for High Repetition Rate Operation at the EuXFEL

WEP44
24 Aug 2022, 16:00
1h 30m
Exhibition Hall (Trieste Convention Centre)

Exhibition Hall

Trieste Convention Centre

Contributed Poster Photon beamline instrumentation & undulators Wednesday posters

Speakers

Kelin Tasca (European XFEL GmbH) Liubov Samoylova (European XFEL GmbH) Raymond Barrett (European Synchrotron Radiation Facility) Anders Madsen (European XFEL GmbH) Ilia Petrov (European XFEL GmbH)Dr Angel Rodriguez-Fernandez (European XFEL GmbH)Dr Roman Shayduk (European XFEL GmbH) Thu Nhi Tran Thi (European Synchrotron Radiation Facility) Alexey Zozulya (European XFEL GmbH) Maurizio Vannoni (European XFEL GmbH)

Description

The European X-ray Free-Electron Laser (EuXFEL) is a unique FEL facility that provides X-ray pulses of high spectral brilliance and high photon flux at MHz repetition rate. However, the high peak power, produced in trains of up 2700 femtosecond pulses at a rate of 10 Hz, induces a periodic temperature increase of the hard X-ray monochromators, thereby reducing their transmitted intensity. To address this limitation, a diamond channel cut monochromator (DCCM) was proposed as an alternative to the currently used silicon monochromators. The heat load effect of typical EuXFEL pulses at 300 K and 100 K was simulated by finite element analysis (FEA) and indicates that the significant reduction of the transmitted intensity occurs after a higher number of pulses when compared to silicon. The DCCM first prototype was manufactured from an HPHT IIa type diamond single block and characterised by rocking curve imaging (RCI). The RCI results demonstrated the high crystalline quality of the DCCM with rocking curve widths of the same order as the width predicted by the dynamical theory and a uniformly reflected intensity over the surface. The performance as a monochromator was demonstrated by measuring the double bounce reflection. The resulting images after two successive reflections showed a diffracted beam of the same size and parallel to the incident beam and confirmed its applicability.

I have read and accept the Privacy Policy Statement Yes

Primary authors

Kelin Tasca (European XFEL GmbH) Liubov Samoylova (European XFEL GmbH)

Co-authors

Raymond Barrett (European Synchrotron Radiation Facility) Anders Madsen (European XFEL GmbH) Ilia Petrov (European XFEL GmbH) Dr Angel Rodriguez-Fernandez (European XFEL GmbH) Dr Roman Shayduk (European XFEL GmbH) Thu Nhi Tran Thi (European Synchrotron Radiation Facility) Alexey Zozulya (European XFEL GmbH) Maurizio Vannoni (European XFEL GmbH)

Presentation materials

There are no materials yet.

Proceedings

Paper