Description
Last preparations for operation for users are ongoing at the new basic facility of the Laboratory of Nuclear Problems of the Joint Institute for Nuclear Research — the LINAC (formerly LINAC-200) accelerator. The facility can provide electron beam with a wide range of energies (5 to 200 MeV), pulse durations (0.25 to 3 us) and charges (240 nC to single electrons per pulse). The maximum pulse repetition rate is 25 Hz. The facility can also provide beams of gamma rays (by installing tungsten converter in the beamline) and neutrons (beryllium converter). Commissioning results and last facility upgrades are presented.