1–6 Jun 2025
Taipei International Convention Center (TICC)
Asia/Taipei timezone

Predicting LANSCE klystron health and performance

WEPB080
4 Jun 2025, 16:00
2h
Exhibiton Hall A _Bear (TWTC)

Exhibiton Hall A _Bear

TWTC

Poster Presentation MC7.T08 RF Power Sources Wednesday Poster Session

Speaker

Aditya Waghmare (Los Alamos National Laboratory)

Description

Beam production through the LANSCE accelerator is currently disrupted due to lack of critical klystrons spares that power the Side Coupled Cavity Linear accelerator (SCCL). The situation is so dire that the facility had to compromise running beam at 100MeV for 2024 run cycle instead of its nominal 800MeV. This project aims to predict the future performance of those critical klystron units through upgrading our current testing capabilities and developing a prediction model that can warn about klystron failures before they happen. This paper will cover improving current measurement, diagnostics, and controls, developing initial klystron health and performance prediction model and automating expert dependent klystron testing. This project will increase klystron reliability for the SCCL enabling LANSCE to provide reliable 800MeV proton beam for the upcoming run cycles.

Funding Agency

Los Alamos National Laboratory

Region represented America
Paper preparation format Word

Authors

Aditya Waghmare (Los Alamos National Laboratory) Deepak Rai (Los Alamos National Laboratory)

Presentation materials

There are no materials yet.