Speaker
Thomas Planche
(TRIUMF)
Description
The main magnet of the TRIUMF 520 MeV cyclotron consists of 4,000-tonnes of steel that needs to produce a field accurate to 3 parts per million across the 18 m diameter cylindrical vacuum chamber. Measurements were done to quantify the field behaviour and a new procedure was developed to reliably restore the field to operating conditions. The ramping and conditioning procedure improved the reproducibility of machine settings and reduced setup time.
Funding Agency
TRIUMF is funded under a contribution agreement with the National Research Council Canada.