Speaker
Description
For years, Instrumentation Technologies and ScandiNova have developed advanced products to optimize RF performances in LINAC applications. In 2024, the companies began integrating the Libera LLRF system into ScandiNova modulators during assembly. This innovation enables the modulators to offer enhanced operational flexibility and improved performances.
This paper will focus on mechanical integration and performance results. The integrated system enables real-time monitoring of critical signals such as drive power to the RF amplifier and klystron, as well as forward and reflected klystron power. Performance metrics include amplitude stability <0.01% RMS and phase stability <0.01° RMS.
Experimental results are presented using a ScandiNova modulator with an Sband klystron and a standard Sband Libera LLRF. Pulse-to-pulse stability measurements demonstrate consistency between conventional electrical methods and RF-based methods, achieving stability in the 10 ppm range. Electromagnetic compatibility tests confirm that the modulators do not interfere with the LLRF system. Additionally, new tools are introduced to identify components with the greatest impact on phase stability.
Region represented | Europe |
---|