Speaker
Chengcheng Xiao
(Shanghai Synchrotron Radiation Facility)
Description
In the SXFEL injector, the beam stability achieved superior performance, maintaining fluctuations below 0.01% after passing through four S-band accelerating units. However, the stability deteriorated to 0.02% upon exiting the X-band linearizer. To mitigate this degradation, a series of targeted enhancements were implemented, including an extensive upgrade of the low-level RF system’s front-end electronics and the integration of adaptive modulation techniques for input signal optimization. These measures effectively restored and improved the beam stability, achieving precision levels within 0.01%.
Region represented | Asia |
---|
Author
Chengcheng Xiao
(Shanghai Synchrotron Radiation Facility)
Co-authors
Cheng Wang
(Shanghai Synchrotron Radiation Facility)
Jianhao Tan
(Shanghai Advanced Research Institute)
Wencheng Fang
(Shanghai Synchrotron Radiation Facility)
Xiaoxia Huang
(Shanghai Synchrotron Radiation Facility)
Yiming Xu
(Shanghai Synchrotron Radiation Facility)