A novel high-precision beam diagnostic system has been designed for slice emittance and energy spread measurements. The 20-meter diagnostic platform integrates eight quadrupoles, a deflecting cavity, and an energy spectrometer, achieving 100fs temporal resolution in both operational modes through the same beamline layout. The emittance measurement mode provides 50-fold horizontal magnification, while the energy spread measurement mode reaches 1.71 keV theoretical energy resolution through optimized dispersion and screen rotation. Comprehensive error analysis confirms measurement precision of 3.05%±0.69% for relative emittance changes and 4.82±1.35 keV for energy spread variations, demonstrating the effectiveness of this flexible design for high-precision beam diagnostics.