Speaker
Description
The APS-Upgrade (APS-U) ID beamline front ends are equipped with next-generation X-ray beam position monitors (XBPMs). Each XBPM utilizes 16-element array detectors to simultaneously capture beam distribution information from undulator and bend magnet (BM) sources. A novel IOC has been designed to handle the following tasks in real time: estimating and subtracting BM signals, applying undulator-gap-dependent calibration to calculate undulator beam center positions, collecting beam position statistics, and estimating X-ray RMS motion and XBPM resolution. Initial data from early APS-U user runs demonstrate significant performance improvements. The BM signal contribution is reduced by more than a factor of 10, observed RMS beam motion is within the micrometer range, and XBPM resolution is consistently below 1 micrometer, typically less than 10% of the RMS beam motion.
Funding Agency
Work supported by the U. S. Department of Energy, Office of Science, under Contract No.DE-AC02-06CH11357.
Region represented | America |
---|---|
Paper preparation format | LaTeX |